Runway & Standard
Rule note
Governs edge-light maximum spacing and the threshold-light minimum-quantity rule. DGCA/AAI projects generally follow the ICAO table unless the approved project specification says otherwise.
Rule note
Drives both the edge-light spacing table and the threshold-light rule: fixed minimum for non-instrument/non-precision, 3 m-spacing geometry for CAT I/II/III.
Rule note
Threshold-to-threshold, or the applicable calculation segment. For a displaced threshold this is the full physical runway length — see the displacement field below.
Rule note
Used only for CAT I/II/III threshold-light geometry below — not required for non-instrument/non-precision runways (fixed minimum applies).
Edge-Light-Row Geometry (for threshold-light span)
Rule note
The distance between the two runway edge-light rows may differ from the pavement width. Use the actual project drawing value where available.
Rule note
WE = Runway width + 2 × offset. ICAO allows edge lights on the runway edge or outside it by not more than 3 m. Leave at 0 if they sit on the edge.
Rule note
ICAO CAT I/II/III threshold-light criterion — uniform spacing not exceeding this value between the edge-light rows. Default 3 m; edit only if a different standard applies.
Rule note
The exact CAT I/II/III fixture count depends on the figure-level endpoint convention (outermost position, centreline treatment), which this calculator does not assume by default — confirm against the applicable standard figure before using as a final quantity.
Threshold, Wing Bar & Runway-End Configuration
Rule note
Each end is a threshold for one direction and the runway end for the other. Threshold, wing-bar and runway-end quantities are worked out for one end and multiplied by this count. If the two ends differ (for example only one threshold is displaced), count them separately.
Rule note
Relevant mainly to non-instrument/non-precision runways with a displaced threshold — wing bars can remove the threshold-light requirement in that configuration.
Display, Validation & Field Checks
Rule note
Output units, decimal precision, and configurable min/max plausible length (in metres) — flags likely data-entry errors only, never blocks calculation.
Verifies achieved edge-light spacing against the applicable maximum.
Rule note
Compares an installed count at one threshold against the calculated nominal threshold quantity for one end.
Report details
Quantity schedule
Runway Light Quantity Schedule
| Component | Calculation Basis | Quantity |
|---|---|---|
| Edge lights — left | Longitudinal spacing | — |
| Edge lights — right | Longitudinal spacing | — |
| Edge lights — total | 2(N + 1) | — |
| Threshold lights | Runway category / configuration | — |
| Threshold wing-bar lights | Applicable configuration | — |
| Runway-end lights | Runway-end configuration | — |
| Calculated nominal total | — |
Calculated / Nominal Quantity — not a Final BOQ Quantity. Threshold/runway-end sharing is applied only where the threshold sits at the runway extremity under the selected standard.
Build-up
How This Calculator Works
Runway lighting quantity is broken into separate components rather than one merged total — ICAO treats runway edge lights, threshold/wing-bar lights, and runway-end lights as distinct provisions with different spacing rules.
Edge-light quantity (inherited from Calculator #01)
For design length L against maximum interval Smax, rounding up (never ordinary rounding, since any excess is a non-compliance):
This calculator reuses the same spacing engine as Calculator #01 so the two tools cannot silently disagree on the edge-light count for the same runway.
Non-instrument / non-precision threshold
ICAO 5.3.10 sets a fixed minimum of 6 threshold lights where threshold lights are required. Where the threshold is displaced and wing-bar lights are provided, the displaced-threshold + wing-bar configuration can remove the threshold-light requirement entirely — this calculator applies that exception only when both conditions are selected, and never infers it from one alone.
Precision CAT I / II / III threshold geometry
The threshold-light count is tied to the edge-light-row span WE and the maximum spacing criterion (3 m by default):
The endpoint adjustment is deliberately not hard-coded. Whether the final fixture count is NT, NT + 1, or another figure-specific value depends on whether both edge-light-row endpoints carry a fixture, whether a centreline position exists, and the exact arrangement in the applicable standard figure (see the applicable ICAO Annex 14 figure). This calculator defaults to +1 but exposes the setting so it is never a hidden assumption.
Runway-end lights — shared or separate
ICAO 5.3.11 requires runway-end lights for a runway equipped with edge lights, but permits fittings serving as threshold lights to also serve as runway-end lights when the threshold is at the runway extremity. This calculator applies that sharing logic automatically when the threshold is not displaced (no additional fixtures added), and treats runway-end lighting as a separate, user-entered component whenever a threshold displacement is selected — since a displaced threshold makes threshold lighting and runway-end lighting distinct geometric elements.
Wing bars are not "extra edge lights"
A wing bar is a separate threshold-lighting arrangement, not simply additional runway edge lights, and its exact fixture count is figure-specific. This calculator asks for the wing-bar quantity directly against the approved layout rather than generating one from a generic formula.
Threshold-light rule by category
| Runway operation | Threshold-light requirement |
|---|---|
| Non-instrument | Min. 6 (where required) |
| Non-precision | Min. 6 (where required) |
| Precision CAT I | At least the 3 m-spacing count (two-group layout permitted) |
| Precision CAT II | ≤ 3 m uniform spacing |
| Precision CAT III | ≤ 3 m uniform spacing |
Working basis: ICAO Annex 14, Volume I. Independently confirm against the exact edition/amendment applicable to your project before relying on this as a standards reference.
Worked geometry examples (CAT II/III, 3 m criterion)
| WE | NT | Achieved spacing |
|---|---|---|
| 30 m | 10 | 3.00 m |
| 44 m | 15 | 2.93 m |
| 46 m | 16 | 2.88 m |
| 45.01 m | 16 | 2.81 m |
Interval count only — apply the endpoint-adjustment setting above to convert to a final fixture count.
Quantity vs. serviceability
This calculator produces an installed fixture quantity. It does not multiply that quantity by a serviceability percentage (the percentages in the maintenance provisions of the governing standard) — quantity and serviceability are separate calculations and should not be combined here.
Indian / AAI & DGCA projects
Treat the design-basis hierarchy as: project specification / approved drawing → applicable DGCA requirement → ICAO Annex 14 where adopted → FAA only where the project specification explicitly calls for it. Select DGCA / Indian or Project-Specific above rather than assuming an ICAO or FAA default applies.