Calculator #02

Runway Light Quantity

Nominal fixture-quantity tool for a full runway lighting configuration — edge, threshold, wing-bar and runway-end lights, calculated as separate components rather than one merged total.

About this calculator

Runway edge-light quantity reuses Calculator #01's validated spacing engine. Threshold-light quantity is split by operational category — a fixed minimum for non-instrument/non-precision runways, and a geometry-based calculation from the edge-light-row span for CAT I/II/III. Runway-end lights are shared with threshold fittings where the threshold sits at the runway extremity, and treated as a separate component where the threshold is displaced. Wing-bar and displaced-threshold runway-end quantities are entered against the approved layout rather than derived from a generic formula, since ICAO's figure-level endpoint arrangement is not reproduced here.

Quick start

Runway & Standard

Rule note

Governs edge-light maximum spacing and the threshold-light minimum-quantity rule. DGCA/AAI projects generally follow the ICAO table unless the approved project specification says otherwise.

Rule note

Drives both the edge-light spacing table and the threshold-light rule: fixed minimum for non-instrument/non-precision, 3 m-spacing geometry for CAT I/II/III.

Rule note

Threshold-to-threshold, or the applicable calculation segment. For a displaced threshold this is the full physical runway length — see the displacement field below.

Rule note

Used only for CAT I/II/III threshold-light geometry below — not required for non-instrument/non-precision runways (fixed minimum applies).

Edge-Light-Row Geometry (for threshold-light span)

Rule note

The distance between the two runway edge-light rows may differ from the pavement width. Use the actual project drawing value where available.

Rule note

WE = Runway width + 2 × offset. ICAO allows edge lights on the runway edge or outside it by not more than 3 m. Leave at 0 if they sit on the edge.

Rule note

ICAO CAT I/II/III threshold-light criterion — uniform spacing not exceeding this value between the edge-light rows. Default 3 m; edit only if a different standard applies.

Rule note

The exact CAT I/II/III fixture count depends on the figure-level endpoint convention (outermost position, centreline treatment), which this calculator does not assume by default — confirm against the applicable standard figure before using as a final quantity.

Threshold, Wing Bar & Runway-End Configuration

Rule note

Each end is a threshold for one direction and the runway end for the other. Threshold, wing-bar and runway-end quantities are worked out for one end and multiplied by this count. If the two ends differ (for example only one threshold is displaced), count them separately.

Rule note

Relevant mainly to non-instrument/non-precision runways with a displaced threshold — wing bars can remove the threshold-light requirement in that configuration.

Display, Validation & Field Checks

Rule note

Output units, decimal precision, and configurable min/max plausible length (in metres) — flags likely data-entry errors only, never blocks calculation.

Verifies achieved edge-light spacing against the applicable maximum.

Rule note

Compares an installed count at one threshold against the calculated nominal threshold quantity for one end.

FAQ

Runway Light Quantity Calculator: Frequently Asked Questions

Quick answers on how the calculator counts edge, threshold, wing-bar and runway-end lights.

What does the Runway Light Quantity Calculator do?

It works out a calculated nominal fixture quantity for a runway, split into edge lights, threshold lights, threshold wing-bar lights and runway-end lights. These are kept as separate components because ICAO treats them as distinct provisions with different spacing rules.

How are runway edge lights counted?

The number of intervals is N = ⌈L ÷ Smax⌉, rounded up because any excess spacing is a non-compliance. That gives N + 1 positions per side and 2(N + 1) edge lights in total. The maximum spacing follows the design standard and runway classification you select. The same spacing engine is used as in Calculator #01, so the two tools cannot disagree on the edge-light count.

How many threshold lights does a non-instrument or non-precision runway need?

ICAO 5.3.10 sets a fixed minimum of 6 threshold lights where threshold lights are required. If the threshold is displaced and wing-bar lights are provided, that configuration can remove the threshold-light requirement. The calculator applies this exception only when both conditions are selected, and never infers it from one alone.

How are CAT I, II and III threshold lights calculated?

The threshold-light count is tied to the edge-light-row span WE, which is the runway width plus twice the edge-light offset. The interval count is NT = ⌈WE ÷ Smax,T⌉, with a default maximum spacing of 3 m, and the fixture count is NT plus an endpoint adjustment. For example, WE = 30 m gives 10 intervals at 3.00 m.

Why is the endpoint arrangement a setting I have to choose?

Whether the final fixture count is NT, NT + 1 or another figure-specific value depends on whether both edge-light-row endpoints carry a fixture and on the exact arrangement in the applicable standard figure. The calculator defaults to +1 but exposes the setting so it is never a hidden assumption. Confirm it against the applicable ICAO Annex 14 figure.

Are runway-end lights counted separately from threshold lights?

It depends on the threshold. ICAO 5.3.11 permits fittings that serve as threshold lights to also serve as runway-end lights when the threshold is at the runway extremity, so no additional fixtures are added in that case. With a displaced threshold, the runway-end lights become a separate element and their quantity is entered per the approved layout.

Which design standard should I select for an Indian project?

The design-basis order is the project specification or approved drawing, then the applicable DGCA requirement, then ICAO Annex 14 where adopted, and FAA only where the project specification calls for it. Select DGCA / Indian or Project-Specific rather than assuming an ICAO or FAA default applies. DGCA and AAI projects generally follow the ICAO table unless the approved project specification says otherwise.

Can I use the result as the final bill of quantities?

No. The result is a calculated nominal quantity, not a final BOQ quantity. It is an installed fixture count and does not include a serviceability percentage. CAT I, II and III threshold counts depend on the endpoint arrangement in the standard figure, and displaced-threshold wing-bar and runway-end quantities are entered against the project layout. Verify all figures against the approved aerodrome lighting drawing before issue.

More Tools

Related Knowledge Hub Resources

Talk to Precision AGL Academy

Follow the Academy

Nominal fixtures—