Electrical & Power Systems Comparison

6.6/6.6 A VS 20/6.6 A

A 6.6/6.6 A isolation transformer has the same rated current on both sides — essentially a 1:1 current-ratio transformer whose main job is electrical isolation. A 20/6.6 A transformer is rated for a 20 A primary and a 6.6 A secondary, so it provides isolation and current transformation together. The notation describes rated currents, not voltage — always confirm actual ratings from the nameplate/datasheet.

At a Glance

Feature 6.6/6.6 A Transformer 20/6.6 A Transformer
Primary rated current6.6 A20 A
Secondary rated current6.6 A6.6 A
Current ratio1:13.03:1
Main functionIsolationIsolation + current transformation
6.6 A AGL circuitDirectly suitedNot normally the primary-side arrangement
Secondary AGL circuit6.6 A6.6 A
Primary current capabilityLowerHigher
Typical applicationStandard AGL series circuitHigher-current/special circuit arrangement
Main differenceSame rated current on both sides20 A primary → 6.6 A secondary

Same Current on Both Sides

The 6.6/6.6 A transformer is rated at 6.6 A on the primary and 6.6 A on the secondary. Because the rated current is the same on both sides, it is essentially a 1:1 current-ratio isolation transformer. Its primary purpose is electrical isolation between the series circuit and the individual light fixture — not current reduction.

6.6/6.6 A Flow

AGL SERIES CIRCUIT
6.6 A
[T]
6.6 A

The rated current entering the transformer equals the rated current leaving it — a straightforward 1:1 isolation stage.

Key Points

  • Primary: 6.6 A · Secondary: 6.6 A
  • Current ratio ≈ 1:1
  • Suited to the standard 6.6 A AGL series lighting circuit
  • Function is isolation, not current transformation

Higher-Current Primary, 6.6 A Secondary

The 20/6.6 A transformer is rated at 20 A on the primary and 6.6 A on the secondary. It is designed to interface a higher-current primary circuit with a 6.6 A secondary circuit, so it provides both galvanic isolation and current transformation in the same unit.

20/6.6 A Flow

20 A CIRCUIT
20 A
[T]
6.6 A

The 6.6 A secondary side then interfaces with an AGL lighting load designed for that current.

Key Points

  • Primary: 20 A · Secondary: 6.6 A
  • Current ratio ≈ 3.03:1
  • Provides isolation and current transformation
  • Interfaces a higher-current arrangement with a 6.6 A load side

Current Ratio Side by Side

The easiest way to remember the difference is by the current ratio each transformer carries between primary and secondary.

6.6 / 6.6 A
1 : 1
Same current → isolation
20 / 6.6 A
3.03 : 1
20 A side converted to 6.6 A side

The Underlying Relationship

For an ideal transformer, approximately:

V₁ × I₁ ≈ V₂ × I₂ — so when the secondary current is lower than the primary current, the corresponding voltage relationship differs accordingly. For the rated current ratio, I₁ / I₂ = 20 / 6.6 ≈ 3.03, giving a current ratio of approximately 3.03 : 1. The actual voltage and power ratings must always be checked from the transformer nameplate/datasheet.

A Simplified Series Circuit

In a simplified AGL series circuit, the Constant Current Regulator (CCR) drives 6.6 A through the series loop into a 6.6/6.6 A transformer, which isolates the individual light from the series circuit and passes the same 6.6 A through to the fixture.

CCR → 6.6/6.6 A → Fixture

CCR
6.6 A
T (6.6/6.6)
6.6 A

The transformer isolates the individual light from the series circuit without changing the rated current.

Interfacing a Higher-Current Circuit

Where the primary-side circuit runs at 20 A, a 20/6.6 A transformer isolates and steps the current down so the 6.6 A secondary side can interface with an AGL lighting load designed for that current.

20 A Circuit → 20/6.6 A → Fixture

20 A CIRCUIT
T (20/6.6)
6.6 A

The 6.6 A secondary side can then interface with an AGL lighting load designed for that current.

Current Rating Is Not Voltage Rating

Do not read 6.6/6.6 A as 6.6 kV / 6.6 kV. Likewise, 20/6.6 A does not by itself specify the transformer's voltage ratio. This notation describes current ratings only. The nameplate/datasheet must always be checked for primary voltage, secondary voltage, rated current, VA/kVA, frequency, insulation level, temperature rise and the applicable standard.

Parameter-by-Parameter View

Parameter 6.6/6.6 A 20/6.6 A
Primary current6.6 A20 A
Secondary current6.6 A6.6 A
Current ratio1:13.03:1
IsolationYesYes
Current conversionNo significant current conversionYes
Standard 6.6 A series circuitTypical fitDepends on application
Primary-side circuit6.6 A20 A
Secondary-side circuit6.6 A6.6 A

Common Misreadings

Myth: 6.6/6.6 A and 20/6.6 A can be swapped since both have a "6.6 A" side
Fact

The two transformers have different primary current ratings and current ratios. A connected circuit must match the transformer's rated current, voltage, VA rating and intended application — not just one shared number.

Myth: The "6.6" and "20" figures describe voltage
Fact

These figures describe rated current, not voltage. Reading 6.6/6.6 A as 6.6 kV/6.6 kV, or assuming 20/6.6 A sets the voltage ratio, is incorrect — voltage must be confirmed separately from the nameplate/datasheet.

Myth: A 20/6.6 A transformer is simply a "bigger" version of a 6.6/6.6 A unit
Fact

It performs a different function. The 6.6/6.6 A unit provides isolation at a 1:1 current ratio, while the 20/6.6 A unit provides isolation together with current transformation across a ≈3.03:1 ratio.

Choosing the Right Rating

When identifying or specifying a 6.6/6.6 A or 20/6.6 A transformer, consider:

Which Transformer Applies Where?

Engineering Verdict

A 6.6/6.6 A transformer carries the same rated current on both sides, making it a 1:1 current-ratio isolation transformer suited to the standard 6.6 A AGL series lighting circuit. A 20/6.6 A transformer is rated for a 20 A primary and a 6.6 A secondary, so it provides isolation together with current transformation for a higher-current or special circuit arrangement.

The notation describes rated current only — it does not specify voltage. Final selection for an actual project should always be based on the transformer nameplate/datasheet, the approved circuit design and the applicable ICAO/national AGL standard.

6.6/6.6 A1:1 current ratio — isolation for the standard 6.6 A series circuit.
20/6.6 A≈3.03:1 current ratio — isolation plus current transformation.

Engineering & Expert Notes

Never Mix Current Ratings on a Circuit by Assumption
Compatibility

The primary current rating must match the series circuit. A unit that fits physically may not be suitable electrically.

Check the Nameplate at Every Replacement
Verification

Read the rating before fitting. Mislabelled or mixed spares are a common cause of wrong replacements.

Know Which Circuit Each Location Belongs To
Records

Mark the circuit current on drawings and registers. It prevents errors when working on mixed airfields.

Treat Primary Connections With Care
Safety

The primary side carries the series current. Follow isolation and permit procedures before any disconnection.

Frequently Asked Questions

What does the "6.6/6.6 A" or "20/6.6 A" notation mean?

It states the primary and secondary rated currents of the transformer — for example, 20/6.6 A means a 20 A primary and a 6.6 A secondary. It does not describe voltage.

Is a 6.6/6.6 A transformer a current-transforming device?

Not significantly. Since the rated current is the same on both sides, it functions essentially as a 1:1 current-ratio isolation transformer.

What is the current ratio of a 20/6.6 A transformer?

Approximately 3.03:1 (20 A ÷ 6.6 A ≈ 3.03), calculated from the rated primary and secondary currents.

Can a 20/6.6 A transformer replace a 6.6/6.6 A transformer?

Not automatically. The connected circuit's rated current, voltage, VA rating and intended application must match the transformer — the two types should not be treated as interchangeable simply because both have a 6.6 A side.

Does 6.6/6.6 A mean 6.6 kV on both sides?

No. The figures describe rated current, not voltage. Voltage ratings must be confirmed separately from the transformer nameplate/datasheet.

Why would a circuit use a 20 A primary feeding a 6.6 A secondary?

To interface a higher-current primary circuit arrangement with a secondary circuit designed for the standard 6.6 A AGL fixture current, combining isolation with current transformation in one unit.

Do both transformer types provide isolation?

Yes. Both the 6.6/6.6 A and 20/6.6 A units provide electrical isolation; the difference is whether current transformation also occurs across the unit.

Governing Documents

For an actual airport project, verify the current applicable editions of the relevant standards and the specific transformer nameplate/datasheet before using this comparison for project design.

ICAO Annex 14, Volume I

Aerodrome Design and Operations — series circuit requirements and isolation transformer current characteristics for AGL.

ICAO Aerodrome Design Manual

Applicable material covering series circuit design and isolation transformer rating guidance.

National CAA / DGCA / AAI Requirements

For Indian airport projects, also verify applicable DGCA requirements, AAI requirements, airport-specific technical specifications, project drawings and contract specifications.

Final Engineering Note

Exact voltage, VA rating and insulation requirements can vary with the governing standard, equipment manufacturer and approved airport design. For final design, use the current applicable standard and manufacturer datasheet rather than a generic comparison page.

6.6/6.6 A describes a 1:1 current-ratio isolation transformer for the standard AGL series circuit; 20/6.6 A describes an isolation transformer that also transforms current from a 20 A primary to a 6.6 A secondary. The notation is current only — voltage, VA and insulation must always be confirmed from the nameplate/datasheet.

Precision AGL Academy

Compare the Systems. Then Learn How to Engineer Them.

Understanding the difference between AGL systems is the first step. The next step is knowing how to design, install, test, commission and maintain them correctly.

Build Practical AGL Engineering Skills

Go deeper with structured training from Precision AGL Academy, covering:

AGL Fundamentals Design & Electrical Engineering Approach Lighting Photometry Installation & Commissioning Maintenance & Troubleshooting

Learn how AGL systems work as part of a complete airport lighting system, not just as individual components or configurations.

Compare. Understand. Apply. Engineer.

Continue Exploring