Photometric Instruments Comparison

GONIOPHOTOMETER VS LUX METER

Beam vs Surface — a goniophotometer characterizes the directional photometric distribution of a fixture, rotating or scanning it through angular positions to build a full intensity profile. A lux meter simply reads the illuminance arriving at one measurement point. For AGL fixture testing, they answer two different questions and are not interchangeable.

At a Glance

Feature Goniophotometer Lux Meter
Main purposeMeasures directional light distributionMeasures illuminance
Main questionHow much light is emitted in each direction?How much light reaches this surface?
Typical outputPhotometric intensity distributionIlluminance value
Main unitCandela (cd)Lux (lx)
Angular measurementYesNo, not by itself
Beam pattern measurementYesNo
Typical setupFixture rotated/measured at multiple anglesHandheld or fixed sensor at a point
AGL useFixture photometric testingSurface/area illuminance measurement
cd
Goniophotometer · Luminous Intensity
lux
Lux Meter · Illuminance

What Is a Goniophotometer & a Lux Meter?

Goniophotometer

A goniophotometer measures how the luminous intensity of a light fixture changes with direction. During measurement, the fixture and/or detector is moved through defined angular positions to obtain luminous intensity versus direction.

Example

0° → 10,000 cd, +5° → 3,500 cd, +10° → 600 cd — a set of readings across angles that together form a photometric distribution.

Lux Meter

A lux meter measures illuminance at the position of its sensor — how much light is falling on a surface or reaching a specific measurement point.

Example

50 lx — a single illuminance reading at the location where the sensor was placed.

Angular Beam vs Fixed Point

AGL Fixture
Goniophotometer
Multiple angles · cd
Lux Meter
Single point · lx
Different Results

A goniophotometer is designed to investigate different angular directions, with the fixture or detector stepped through positions around the source. A lux meter is generally placed at one specified measurement point — moving it to another location gives another illuminance reading, but this alone does not build a complete, standardized photometric distribution.

Easy memory: Goniophotometer → measures the BEAM. Lux meter → measures the ILLUMINATION received.

What Each Instrument Reports

Goniophotometer Output

Typically represented as:

  • Intensity vs horizontal angle
  • Intensity vs vertical angle
  • Polar distribution
  • Photometric data tables

Lux Meter Output

Typically a single value, or a small set of point readings:

  • Measurement Point → 35 lx
  • Point 1 → 32 lx
  • Point 2 → 38 lx
  • Point 3 → 35 lx

What a Goniophotometric Test Evaluates

AGL lights are often designed to provide specific light output within specified angular sectors, so a goniophotometric test on an AGL fixture can evaluate:

Area Illuminance Measurement

A lux meter is useful for measuring illuminance across an area, taking readings at a grid of points to help evaluate surface illumination, illuminance distribution, and uniformity where required.

Grid Point Illuminance
P145 lx
P250 lx
P342 lx
P448 lx

Can a Lux Meter Replace a Goniophotometer?

Generally, no. A lux meter can measure illuminance at specified locations, but a goniophotometric system is designed to accurately characterize the directional photometric performance of a fixture — "how much light arrives here?" is a different question from "how does the fixture perform over many directions?"

How the Two Readings Connect

Under simplified point-source and normal-incidence conditions, the intensity a goniophotometer measures and the illuminance a lux meter measures are related by the inverse-square law:

E = I / r²

Inverse-square relationship between intensity and illuminance

  • E = illuminance, in lux
  • I = luminous intensity, in candela
  • r = distance, in metres
I = 1,000 cd, at 10 m
10 lx
E = 1,000 / 10²
Same fixture, same direction
≠
Illuminance changes with distance; intensity does not

This illustrates the relationship, although real photometric measurements must account for measurement geometry and applicable test procedures.

Same AGL Light, Two Different Readings

With a Goniophotometer

−5° → 3,000 cd
0° → 8,000 cd
+5° → 4,000 cd

You learn about

The beam pattern.

With a Lux Meter

One sensor, one location → 25 lx

You learn about

The illuminance at that point.

Which Instrument for Which Task

Application Better Instrument
Measure luminous intensityGoniophotometer
Measure beam distributionGoniophotometer
Measure horizontal photometryGoniophotometer
Measure vertical photometryGoniophotometer
Determine beam spreadGoniophotometer
Measure surface illuminanceLux meter
Perform illuminance surveyLux meter
Check area illumination uniformityLux meter

Full Engineering Parameters

Parameter Goniophotometer Lux Meter
MeasuresDirectional photometric performanceIlluminance
Primary unitcdlx
Angular scanningYesNo
Beam distributionYesNo
Surface illuminanceNot its primary purposeYes
Fixture characterizationExcellentLimited
Area illumination surveyNot typicalExcellent
Test complexityHigherLower
Typical resultPhotometric curve/tablePoint/grid readings

Myths vs Facts

Myth: "A lux meter can completely characterize an AGL fixture"
Fact

Not by itself. A lux meter only measures illuminance at its own location. A complete photometric characterization of a directional AGL fixture requires intensity/distribution measurements across the relevant directions.

Myth: "Moving a lux meter around gives the same result as a goniophotometer"
Fact

No. Repositioning a lux meter gives more point readings, but not a standardized angular intensity distribution referenced to the fixture itself.

Myth: "Candela and lux are the same thing, just different names"
Fact

No. Candela describes intensity emitted by the source in a direction; lux describes illuminance received at a surface. They are related by geometry, not identical.

Myth: "A goniophotometer is only needed once, at type approval"
Fact

Goniophotometric testing is central to type/photometric approval, but distribution checks may also be relevant whenever fixture design, optics, or in-service condition changes are being assessed.

Goniophotometer vs Lux Meter

Engineering Verdict

A goniophotometer and a lux meter answer different questions. The fundamental difference is what is being characterized — the fixture's directional beam, or the illuminance at a receiving location.

A goniophotometer characterizes an AGL fixture's photometric performance across angles, producing the intensity distribution that fixture and beam specifications are built around. A lux meter measures how much of that light actually lands on a surface at a given point, which is what surface illuminance and uniformity requirements are built around. Neither instrument substitutes for the other.

GoniophotometerAngular scan of the fixture + candela + characterizes the beam.
Lux MeterPoint/grid reading at a surface + lux + characterizes the illumination received.

For AGL: reach for a goniophotometer to test and characterize a fixture's photometric performance, and a lux meter to check illuminance on the runway or taxiway surface.

Engineering & Expert Notes

Use the Instrument for the Question Being Asked
Principle

One characterises a fixture; the other measures illumination. Do not substitute.

Control Position and Orientation With a Lux Meter
Setup

Small changes alter readings. Mark positions and record them.

State Calibration Status in Reports
Calibration

Include calibration dates and traceability for both.

Interpret Results Against the Right Requirement
Interpretation

Candela data and lux data answer different requirements.

Frequently Asked Questions

What is the simplest way to remember the difference?

Goniophotometer → BEAM (how the fixture's intensity is distributed across directions). Lux meter → SURFACE (how much light reaches a given point).

Can a lux meter replace a goniophotometer for AGL fixture testing?

Generally no. A lux meter reads illuminance at its own location; it does not by itself produce a standardized angular photometric distribution of the fixture.

What does a goniophotometer actually output?

Intensity values across angles, typically presented as intensity vs horizontal angle, intensity vs vertical angle, a polar distribution, or a photometric data table.

Why does AGL fixture testing rely on angular measurement at all?

Because AGL lights are highly directional — approach lights, edge lights, centreline lights and PAPI units are designed to project specific intensity within defined angular sectors, so performance has to be verified across those angles, not at a single point.

Are candela and lux related by a formula?

Under simplified point-source, normal-incidence conditions, E = I / r² relates illuminance (lux) to intensity (candela) and distance, though real measurements must account for geometry and applicable test procedures.

When is a lux survey the right tool instead of a goniophotometric test?

When the question is about surface illumination — how much light reaches the pavement across an area, and how uniform it is — rather than about the fixture's own directional performance.

Governing Documents

For an actual project design, always verify the current edition of the applicable documents.

FAA AC 150/5340-30

Design and Installation Details for Airport Visual Aids — photometric requirements referenced when interpreting goniophotometric intensity data and lux-based illuminance in AGL specifications.

ICAO Annex 14, Volume I

Aerodrome Design and Operations — photometric characteristics of aeronautical ground lights, intensity and colour requirements over specified angular sectors.

CIE Photometry Standards

International Commission on Illumination definitions and measurement methods for luminous intensity, illuminance, and goniophotometric test geometry.

Final Engineering Note

Do not treat a lux reading as a substitute for a goniophotometric intensity distribution in a project specification. Confirm which photometric quantity the governing standard actually requires before selecting an instrument or acceptance criterion.

A goniophotometer characterizes the light source and its beam distribution; a lux meter measures the resulting illuminance at the receiving location.

Precision AGL Academy

Compare the Systems. Then Learn How to Engineer Them.

Understanding the difference between AGL systems is the first step. The next step is knowing how to design, install, test, commission and maintain them correctly.

Build Practical AGL Engineering Skills

Go deeper with structured training from Precision AGL Academy, covering:

AGL Fundamentals Design & Electrical Engineering Approach Lighting Photometry Installation & Commissioning Maintenance & Troubleshooting

Learn how AGL systems work as part of a complete airport lighting system, not just as individual components or configurations.

Compare. Understand. Apply. Engineer.

Continue Exploring