Photometric Fundamentals Comparison

PHOTOMETRIC INTENSITY VS AVERAGE INTENSITY

Intensity at a Point vs Intensity Over a Range — photometric intensity describes the luminous intensity in one specific direction, while average intensity reduces several directional readings across a defined angular range into a single mean value. Both are expressed in candela, but they answer different engineering questions on an AGL fixture's beam.

At a Glance

Feature Photometric Intensity Average Intensity
MeaningIntensity at a specific direction/angleMean intensity over a specified range
UnitCandela (cd)Candela (cd)
Directional detailHighReduced into one value
Shows beam patternYesNo, not by itself
Used forDetailed photometric performanceOverall/representative intensity
AGL relevanceVery importantUseful for summarizing performance
Example8,000 cd at 3° elevation6,500 cd average from 2°–5°
cd
Photometric Intensity Unit
cd
Average Intensity Unit

What Is Photometric Intensity & Average Intensity?

Photometric Intensity

The luminous intensity in a particular direction from a fixture. For an AGL light, each angle around the beam has its own photometric intensity value, and together these values describe the photometric intensity distribution.

Example distribution

DirectionIntensity
0°5,000 cd
1°7,000 cd
2°9,000 cd
3°8,000 cd
4°6,000 cd
5°3,000 cd

Average Intensity

The mean luminous intensity taken over a defined angular range or set of directions. It reduces several directional readings into one representative figure.

Worked example

Using the 2°–4° readings from the distribution at left:

Iavg = (9000 + 8000 + 6000) / 3

Iavg = 7,667 cd for those three directions

Point/Direction vs Range/Mean

"What is the intensity HERE?"

Photometric intensity answers this at one specific angle — for example, 8,000 cd at 3°.

"What is the MEAN intensity over this range?"

Average intensity answers this across several directions — for example, (9,000 + 8,000 + 6,000) / 3 = 7,667 cd.

Easy memory: Photometric intensity → POINT/DIRECTION. Average intensity → RANGE/MEAN.

Why This Matters on the Beam

AGL lights are directional. An approach or runway light must produce appropriate intensity over a particular angular region as an aircraft moves through the beam. The individual directional intensities show how the light actually performs across that beam.

An average value can summarize part of that performance, but on its own it cannot show the detailed distribution an aircraft will actually encounter.

Same Average, Different Beams

Consider two fixtures with very different beam shapes that happen to share the same average intensity.

10,000
A·1
10,000
A·2
10,000
A·3
10,000
A·4
2,000
B·1
8,000
B·2
12,000
B·3
18,000
B·4

Fixture A (flat 10,000 cd throughout) and Fixture B (2,000 / 8,000 / 12,000 / 18,000 cd) both average to 10,000 cd — yet their beam distributions are clearly different. The same average intensity does not mean the same photometric performance.

Photometric vs Peak vs Average Intensity

Peak intensity is often confused with average intensity, but the two are distinct.

Term Meaning
Photometric intensityIntensity at a specified direction
Peak intensityHighest intensity found in the relevant distribution
Average intensityMean intensity over a defined range
0°–4° readings: 4,000 / 7,000 / 10,000 / 8,000 / 5,000 cd

Peak intensity (at 2°) = 10,000 cd  |  Average over 0°–4° = 6,800 cd

Peak ≠ Average ≠ Individual directional intensity — each answers a different engineering question.

Horizontal-Direction Measurements

Imagine an AGL light with the following horizontal-direction photometric intensity readings:

Angle Photometric Intensity
−5°2,000 cd
−2.5°6,000 cd
0°10,000 cd
+2.5°7,000 cd
+5°3,000 cd
Iavg = (2000+6000+10000+7000+3000) / 5

Iavg = 5,600 cd across those five points

"Average" Depends on the Governing Test

The exact meaning of average intensity depends on how the applicable test or specification defines the averaging. It could involve a defined angular interval, specific measurement directions, a specified beam sector, or multiple measurement points.

Do not assume "average intensity" always means a simple average of any arbitrary measurements. For an actual AGL compliance test, the applicable specification/test procedure controls the calculation.

Source-Side Intensity vs Surface Illuminance

Photometric and average intensity are both source-side directional quantities. They describe what the fixture emits, not what a surface downstream actually receives.

AGL Fixture
Directional Intensity
Photometric / average · cd
Surface
Illuminance received · lux

See also: Luminance vs Illuminance and Photometry vs Lux Measurement.

Myths vs Facts

Myth: "Two fixtures with the same average intensity perform the same"
Fact

Incorrect. A flat 10,000 cd distribution and a steeply varying 2,000–18,000 cd distribution can share the same 10,000 cd average while producing very different beam performance.

Myth: Average intensity and peak intensity are the same thing
Fact

They are different quantities. Peak intensity is the single highest value in a distribution; average intensity is the mean across a defined range, and the two rarely coincide.

Myth: "Average" always means a simple mean of whatever points you choose
Fact

The applicable specification or test procedure defines exactly which points, intervals, or sectors go into the average — it is not left to arbitrary interpretation.

Full Engineering Parameters

Parameter Photometric Intensity Average Intensity
RepresentsDirectional light intensityMean directional intensity
MeasurementSpecific angle/directionDefined range/set of directions
Unitcdcd
Beam detailPreservedReduced
Peak identificationPossibleNot from average alone
Beam uniformityCan be assessed from distributionLimited
AGL fixture testingFundamentalSupplementary/summary measure
Same value for different beams?Less likelyPossible

Photometric Intensity vs Average Intensity

Engineering Verdict

Photometric intensity and average intensity are not interchangeable quantities. Both are expressed in candela, but they answer different questions about the beam.

Photometric intensity preserves the detailed beam distribution at a specific direction; average intensity reduces a defined angular range to a single representative value. A fixture can share the same average with a very different fixture while performing very differently across the actual beam. Which value applies depends on what the governing specification is asking for.

PhotometricIntensity at a specific angle + candela + full beam detail preserved.
AverageMean intensity over a defined range + candela + detail reduced to one figure.

For AGL: use photometric intensity to evaluate how the beam actually performs at each angle, and average intensity when a specification asks for a single representative figure over a defined range.

Engineering & Expert Notes

Do Not Let an Average Hide a Weak Point
Principle

Check individual points against requirements.

Report Point Values as Well as the Mean
Reporting

Show the individual data.

Align Before Measuring
Setup

Orientation affects readings.

Retest After Corrective Action
Verification

Confirm the fix with the same method.

Frequently Asked Questions

What is the simplest way to remember the difference?

Photometric intensity → POINT/DIRECTION (intensity at one angle). Average intensity → RANGE/MEAN (intensity averaged over several angles).

Are photometric intensity and average intensity measured in the same unit?

Yes. Both are expressed in candela (cd), because both are based on luminous intensity. The difference is how the value is represented, not the unit.

Can two fixtures have the same average intensity but different beam shapes?

Yes. A flat distribution and a widely varying distribution can produce the same average, even though their actual photometric performance across the beam is very different.

Is average intensity the same as peak intensity?

No. Peak intensity is the single highest value in a distribution, while average intensity is the mean over a defined range. The two are rarely equal.

Does "average intensity" always mean the same calculation?

No. The applicable test or specification defines which angular interval, directions, or beam sector are used in the averaging — it is not a fixed, universal calculation.

How does this relate to illuminance in lux?

Photometric and average intensity are source-side quantities describing what the fixture emits in candela. Illuminance in lux describes what a surface downstream actually receives once that light travels and lands.

Governing Documents

For an actual project design, always verify the current edition of the applicable documents.

FAA AC 150/5340-30

Design and Installation Details for Airport Visual Aids — photometric intensity requirements and averaging methods for runway and approach lighting.

ICAO Annex 14, Volume I

Aerodrome Design and Operations — photometric characteristics of aeronautical ground lights, including intensity distribution requirements.

CIE Photometry Standards

International Commission on Illumination definitions and measurement methods for luminous intensity and its averaging.

Final Engineering Note

Do not treat an average-intensity figure as equivalent to the full photometric distribution. Confirm which quantity, and which averaging method, the governing standard actually requires.

Photometric intensity is not average intensity — one preserves the beam's detailed distribution, the other summarizes a defined portion of it into a single figure.

Precision AGL Academy

Compare the Systems. Then Learn How to Engineer Them.

Understanding the difference between AGL systems is the first step. The next step is knowing how to design, install, test, commission and maintain them correctly.

Build Practical AGL Engineering Skills

Go deeper with structured training from Precision AGL Academy, covering:

AGL Fundamentals Design & Electrical Engineering Approach Lighting Photometry Installation & Commissioning Maintenance & Troubleshooting

Learn how AGL systems work as part of a complete airport lighting system, not just as individual components or configurations.

Compare. Understand. Apply. Engineer.

Continue Exploring