AGL Component Library By Precision AGL Academy

ALSF‑2

A high‑intensity approach lighting system for Category II and III precision approaches, featuring a full 731m (2,400 ft) – or 914m (3,000 ft) – configuration of barrettes, sequenced flashing lights, and additional red side‑row bars. The ALSF‑2 provides exceptional visual guidance for low‑visibility operations down to 200m RVR, enabling safe landings in the most demanding weather conditions.

ALSF‑2 Approach Lighting System

Image disclaimer: For identification and illustration only. It may show a product by another manufacturer and may not depict the exact item described; it is not a statement of any product’s quality, approval or performance. Third-party image and trademark rights belong to their owners. See full notice.

Overview

What Is It?

The ALSF‑2 (Approach Lighting System with Sequenced Flashing lights – Category II/III) is a high‑intensity precision approach lighting system designed for the most demanding low‑visibility operations. It extends 731 metres (2,400 ft) – or 914 metres (3,000 ft) on shallow-slope sites – from the runway threshold and includes all the features of the ALSF‑1 plus additional red side‑row bars and enhanced intensity. The system provides pilots with both horizontal and vertical guidance during CAT II and CAT III approaches, with decision heights as low as 100ft (CAT II) and 50ft or less (CAT III), and RVR down to 200m or lower. The ALSF‑2 is essential for airports that operate in regions with frequent fog, rain, or snow.

Purpose

Purpose & Function

ALSF-2 exists to extend the ALSF-1 foundation specifically to the point where CAT II and CAT III minimums become achievable, adding red side-row bars and enhanced intensity precisely because the lower decision heights and shorter visual segments of those categories demand more visual information delivered with greater reliability than CAT I alone requires. The red side-row bars in particular give the pilot a distinct visual marker of entering the final, most critical approach segment, an added layer of positional awareness that CAT I operations don't need but that CAT II/III's tighter margins make valuable. Its purpose is to be the standard high-intensity system wherever an airport must support routine operations in the fog, rain, or snow-prone conditions that make CAT II/III capability operationally necessary rather than optional.

Application

Where Is It Used?

ALSF‑2 systems are installed at airports that support Category II and III precision approaches. They are typically used on:

  • Precision approach runways with CAT II/III capability (100ft DH or lower, 200m RVR or lower)
  • Major international hub airports requiring reliable low‑visibility operations
  • Airports in regions with adverse weather (fog, heavy rain, snow)
  • Military airbases supporting all‑weather operations
  • Runways with high traffic volume where operational continuity is critical
Placement

Installation & Location

Fixtures are set out along the extended runway centreline for the full 900 m length, on frangible stands graded to the approach slope; structures crossing roads, water, or depressions are elevated on piers or catwalks to keep the array on a consistent plane. The red side-row bars and threshold-adjacent lights in the final 300 m are tied into the runway's own lighting so the transition from approach to runway reads as one continuous system. Because ALSF‑2 supports CAT II/III operations, stands and cabling are typically arranged on independently fed circuits so a single fault cannot extinguish the full array, with cable runs in duct back to redundant constant current regulators. Setting-out follows the extended centreline and threshold survey to the same tolerance as the runway lighting it feeds into.

Function

How Does It Work?

The ALSF‑2 system builds on the ALSF‑1 with enhanced features for lower visibility:

  • Barrettes: A series of light bars (typically 3 to 5 lights per bar) positioned at 30m (100 ft) intervals along the full 731m/914m approach path. These provide distance and lateral guidance.
  • Sequenced Flashing Lights (SFL): A row of lights that flash in sequence from the outer end toward the threshold, creating a "rolling" effect that indicates the approach direction and helps pilots maintain the correct glide slope. The SFL in ALSF‑2 has higher intensity and faster flash rate for better visibility in fog.
  • Red Side‑Row Bars: Additional red lights installed on both sides of the approach path in the final 300m segment. These provide a visual warning if the aircraft deviates laterally from the centreline and help define the approach corridor.
  • Centreline Barrette: A short row of lights on the approach centreline, providing precise lateral guidance and helping pilots align with the runway.
  • Decision Bar: A row of lights at the decision height point, providing a visual reference for the pilot's go/no‑go decision.
  • Intensity Control: The entire system is controlled by CCRs with multiple intensity steps (typically 5 steps), with higher intensities used during low‑visibility conditions. The system also includes automatic dimming based on RVR data.
Architecture

System Architecture & Control Logic

As with ALSF‑1, the ALSF‑2 array runs two electrically independent control paths. Steady-burning elements — barrettes, red side-row bars, centreline barrette, and the decision bar — sit on a constant current series circuit: the ALCMS selects the intensity step based on RVR, ATC instruction, or automatic visibility-linked logic, the CCR regulates the whole loop to a single fixed current, and every steady fixture on that loop burns at the same brightness via its own isolating transformer. The sequenced flashing lights are driven separately by a flasher/sequencer controller that discharges through each SFL lamp in strict outer-to-threshold order; in ALSF‑2 this sequencer is tuned for a higher flash rate and higher peak intensity than ALSF‑1 for better fog penetration. The ALCMS commands both subsystems in step together — raising RVR-linked brightness raises both the steady loop's current and the SFL's intensity tier — but a fault in one subsystem does not propagate to the other, and each is fault-monitored independently by its own controller.

ALCMS commands both the steady CCR loop and the high-intensity SFL sequencer in step

AIRFIELD LIGHTING CONTROL SYSTEM (ALCMS) RVR-linked step selection, drives both subsystems together CONSTANT CURRENT REGULATOR Converts step command to fixed loop current STEADY-FIXTURE SERIES CIRCUIT LOOP Feeds barrettes, red side-rows, centreline & decision bar ISOLATING TRANSFORMER (PER FIXTURE) Taps fixed loop current to each steady fixture HIGH-RATE SFL FLASHER / SEQUENCER Capacitor-discharge, faster rate & higher peak than ALSF-1 BARRETTES / SIDE-ROWS / DECISION BAR Steady-burning — all fixtures at one intensity SEQUENCED FLASHING LIGHTS Outer lamp to threshold, tuned for fog penetration APPROACH LIGHT PATTERN TO PILOT Steady bars and rolling flash combine into one visual cue TWO INDEPENDENT SUBSYSTEMS, RVR-LINKED IN STEP
Layout

Approach Path Sequence

Sequenced Flashing Lights — Outer End731m/914m from threshold, high-intensity, fast flash rate for fog penetration
▸▸▸▸▸▸▸

Faster, higher-intensity flash sequence rolls toward the runway — enhanced over ALSF‑1 for CAT II/III visibility

Centreline BarrettesSteady white, 30m (100 ft) intervals along the full 731m/914m length
RED BAR
Final 300m SegmentRed side-row bars flank the centreline — warn of lateral deviation
RED BAR
Decision BarMarks the decision height — pilot's go / no-go reference point
Runway ThresholdVisual contact confirmed, or missed approach if not established
Construction

Physical Construction

Barrette stands are frangible structures carrying multiple lamp housings on a rigid bar, graded in height along the stand run to keep the array on the approach slope; die-cast aluminium housings behind toughened, gasket-sealed lenses achieve an IP67/IP68 rating on each lamp. The sequenced flashing heads use higher-output xenon strobe tubes and trigger electronics than a CAT I system, housed in weatherproof domes with correspondingly larger capacitor banks at the base of each stand to sustain the faster, higher-intensity sequence. Red side-row bar fixtures in the final 300 m and the threshold-adjacent lights share the same die-cast, gasket-sealed construction as the runway's own edge and threshold lights, so the approach hardware transitions seamlessly into the runway lighting system. Where the approach crosses roads, water, or depressions, stands are raised on piers or catwalks engineered to keep the array coplanar, and because ALSF-2 supports CAT II/III operations, circuits are built with independent cabling and redundant isolating transformers so a single fault cannot take down the full array. Stainless-steel fasteners and corrosion-resistant finishes are used throughout.

Specification

Technical Parameters

ParameterTypical Value
System TypeALSF‑2 (CAT II/III precision approach)
Light SourceLED array or halogen (100W – 200W, high‑intensity)
ColourWhite (steady and flashing), Red (side‑row bars)
Configuration Length731 metres / 2,400 ft (standard) – 914 metres / 3,000 ft (extended, shallow-slope sites)
Barrette Spacing30m (100 ft) intervals along full length
Sequenced Flashing LightsHigh‑intensity, fast sequence (flashing toward threshold)
Side‑Row BarsRed lights on both sides of the final 300m segment
Decision BarPresent at decision height point
Intensity Steps5‑step (2.8A – 6.6A) CCR controlled, with automatic dimming
Beam PatternUni‑directional towards approach, narrow beam for high intensity
Mounting TypeElevated or flush‑mounted (inset)
Isolating Transformer100W – 200W (6.6A series circuit)
Protection ClassIP67 / IP68 (submersible)
SupportCAT II (100ft DH, 300m RVR) / CAT III (50ft or less DH, 200m or less RVR)
Power Supply

Electrical Requirements

RequirementTypical Value
Circuit TypeIndependent series circuits (CCR fed) for centreline barrettes, red side-row bars, and SFL/strobe array
Rated Series Current6.6A per circuit (5-step: 2.8A / 3.4A / 4.1A / 5.2A / 6.6A)
IsolationDedicated isolating transformer (100W – 200W) per fixture; SFL heads fed from dedicated capacitor-discharge units
Transformer SecondaryMatched to fixture wattage; sized to series circuit rating
SFL Power SupplyHigh-output capacitor-discharge trigger units driving xenon strobes, synchronised by a flasher controller at the faster CAT II/III sequence rate
Cable TypeL-824 single-conductor, direct-burial rated, 5kV per circuit; shielded trigger cable for SFL synchronisation
ConnectorL-823 primary connector, submersible-rated splice
Insulation Resistance≥ 50 MΩ (megger test, cable-to-ground)
Earthing/GroundingFixture body, stands, and base cans bonded to airfield earth grid
Fault ProtectionCCR-level ground fault and open-circuit detection per circuit sector; SFL controller health monitoring
RedundancyIndependent cabling and duplicate isolating transformers per circuit sector, so a single fault cannot take down the full array
Power SourceCCR output per circuit, regulated per ICAO/FAA CAT II/III intensity step schedule
Optical Performance

Photometric Requirements

ParameterTypical Value
Centreline Barrette Intensity10,000 – 20,000 cd (white), 5-step: 100% / 30% / 10% / 3% / 1%
Red Side-Row Bar Intensity≥ 2,000 cd (red) from 1,000 ft to touchdown-side row
SFL Peak Effective Intensity≥ 20,000 effective cd (white xenon strobe), higher-output units toward CAT III end of the range
SFL Flash RateFaster sequence rate than ALSF-1, synchronised outward-to-threshold along the centreline
Vertical Beam SpreadMain beam 1°–12° above horizontal (peak ~2°–3°)
Horizontal Beam Spread± 4.5° either side of runway centreline extended, plus dedicated red side-row spread
ChromaticityWhite (centreline/SFL) and red (side-row bars) within ICAO Annex 14 boundaries
Isocandela DistributionPer ICAO Annex 14 Attachment A / FAA AC 150/5340-30 ALSF-2 figures
Test MethodMobile photometric van/goniophotometer per circuit sector, plus SFL flash-timing verification against the CAT II/III sequencing schedule
Compliance

Applicable Standards

ICAO Annex 14

ALSF‑2 configuration, spacing, colour, and photometric requirements

FAA AC 150/5345-46

Specification for ALSF‑2 approach lighting components

IEC 61827

Electrical and photometric performance for AGL luminaires

FAA Engineering Brief #67

LED ALSF‑2 component performance requirements

Prerequisites

Installation Requirements

Frangible Stand Footing & Slope Grading
Civil

Set each stand footing along the full 900 m run to the design height so the array follows the approach slope, holding tolerance from the outer end through to the threshold.

Elevated Piers & Catwalks Over Obstacles
Civil

Install piled structures or catwalks wherever the approach crosses roads, water, or depressions, engineered to keep the array coplanar across the full length.

Duct & Redundant Cable Routes
Electrical

Lay independently routed duct runs for the steady, high-intensity SFL, and red side-row bar circuits, keeping each on its own feeder so a single fault cannot extinguish the full array.

L-823 Connector Termination
Electrical

Terminate and seal primary connectors on every circuit per manufacturer procedure, keeping each splice fully submersible-rated before backfill.

Redundant Isolating Transformer Matching
Electrical

Confirm isolating transformer wattage and ratio match each circuit's rated current step, with steady, SFL, and side-row transformers kept on their independently fed loops.

Barrette, SFL & Side-Row Assembly
Mechanical

Fix lamp housings to barrette bars, mount SFL heads on their stands, and install red side-row bar fixtures in the final 300 m, torquing all frangible fittings to spec.

Setting-Out & Runway Transition
Mechanical

Tie stand positions to the extended centreline and threshold survey to the same tolerance as the runway lighting it feeds into, keeping the approach-to-runway transition continuous.

Pre-Energisation Sign-off
Documentation

Record stand positions, redundant cable routes, connector seals, and torque values as-built for every circuit before backfill, since these are not inspectable once the site is closed.

Verification

Testing & Commissioning

Insulation Resistance (Megger) Test
Pre-Energisation

Megger-test the steady-burning circuit, the high-intensity SFL circuit, and the red side-row bar circuit separately before backfill, confirming each clears the acceptable minimum.

Loop Continuity & Resistance Test
Pre-Energisation

Verify series loop continuity and record total loop resistance for the full 731m/914m run, including the side-row bars and decision bar, before first energisation.

Primary/Secondary Voltage Verification
Energisation

With the CCR energised, confirm secondary voltage at each barrette and side-row bar transformer matches the rated ratio at the commissioned current step.

Automatic RVR-Linked Dimming Verification
Energisation

Simulate a range of RVR inputs to the ALCMS and confirm the CCR automatically steps intensity up or down in line with CAT II/III visibility-linked control logic.

Sequenced Flashing & Decision Bar Response
Energisation

Confirm the high-intensity SFL sequence fires correctly toward the threshold and that the decision bar illuminates and aligns with the decision-height reference point.

Side-Row Bar & Barrette Alignment Verification
Final Acceptance

Check elevation, azimuth, and colour segregation of every barrette and red side-row light against the design aiming diagram, correcting any deviation before sign-off.

Photometric Commissioning Test
Final Acceptance

Measure beam intensity and colour of white and red elements with a calibrated photometer against ICAO/FAA CAT II/III commissioning tolerances.

Documentation & As-Built Sign-off
Final Acceptance

Record insulation, continuity, voltage, dimming-response, and photometric readings alongside as-built positions in the commissioning dossier for handover.

Upkeep

Inspection & Maintenance

Photometric Intensity Check
Annual

Verify barrette, side-row bar, and centreline beam intensity against ICAO / FAA thresholds using a calibrated photometer across the full 731m/914m high-intensity configuration.

Barrette & Side-Row Lens Cleaning
Quarterly

Clear dust, insect residue, and weathering film from barrette, side-row, and centreline lenses so beam output stays within spec at CAT II/III intensity levels.

Sequenced Flasher Timing Test
Semi-annual

Confirm the high-intensity sequenced flashers fire in the correct rapid outer-to-threshold order, since a stuck or mistimed flasher undermines the approach cue at low visibility.

Decision Bar Function Check
Semi-annual

Verify the decision bar at the decision height point illuminates correctly and at the specified intensity, since this is the critical go/no-go visual reference for the crew.

Automatic Dimming / CCR Step Verification
Semi-annual

Confirm the CCR delivers the correct current at each of its 5 intensity steps and that automatic dimming responds correctly to commanded settings.

Seal & Gasket Inspection
Annual

Check top-cap O-rings and gaskets across elevated and inset fixtures for cracking or compression set, and re-torque fasteners to keep each unit watertight.

Insulation Resistance Test
Annual

Megger-test the isolation transformers and series circuit feeding the configuration to confirm resistance stays above minimum, flagging moisture ingress before it causes a circuit-wide fault.

Cable & Connector Inspection
Annual

Examine primary and secondary cable connections across the array for corrosion or loose crimps, a common source of intermittent series-circuit faults over a run this long.

Field Notes

Common Field Issues

Lens Contamination

ALSF‑2 components are exposed to severe environmental conditions, including fog, rain, snow, and de‑icing chemicals. Regular cleaning with approved solvents and soft brushes is essential to maintain light output and visibility, especially for the critical side‑row bars.

Sequenced Flashing Light (SFL) Synchronisation Failure

The SFL system in ALSF‑2 relies on precise timing and control electronics. Failure of a single light or control unit can disrupt the flashing sequence, confusing pilots. Regular inspection and testing of the SFL system is critical, with redundant controllers recommended.

Misalignment of Elevated Fixtures

Elevated ALSF‑2 components can be knocked out of alignment by wind, wildlife, or maintenance vehicles. Regular alignment checks using a theodolite or laser alignment system are essential, especially for the side‑row bars which must be precisely positioned.

Power Supply and CCR Issues

ALSF‑2 systems draw significant power and require precise current regulation. Voltage fluctuations, CCR faults, or cable damage can cause inconsistent brightness or total failure. Regular power quality monitoring, cable testing, and CCR maintenance are recommended.

Red Filter Degradation

The red side‑row bars use colour filters that can degrade over time due to UV exposure and thermal stress. The red colour may fade or shift toward orange, reducing the effectiveness of the visual cue. Regular photometric testing and filter replacement are essential.

Diagnostics

Troubleshooting Guide

Single Light/Bar Dark, Rest of Array Normal
Likely Cause
Failed lamp/LED source, or an open isolating transformer at that fixture (blown primary link or failed secondary winding).
Diagnostic Steps
Confirm series loop continuity through the fixture's transformer primary; megger the transformer; check secondary voltage at the connector with the CCR energised.
Corrective Action
Replace the lamp/LED source if the transformer checks healthy; otherwise swap the isolating transformer and re-seal the L-823 connectors before backfill.
Entire Array Dark / CCR Will Not Regulate
Likely Cause
Open-circuit fault in the series loop feeding the approach lights (severed cable, corroded splice, or a failed transformer acting as an open point).
Diagnostic Steps
Check the CCR fault/open-circuit indication first; loop-resistance test from the CCR output to isolate the faulted segment; sectionalise and megger cable runs along the approach centreline to narrow down the break.
Corrective Action
Excavate and repair or replace the faulted cable section and connector; re-test insulation resistance before reinstating the circuit.
SFL Sequence Irregular or Out of Step
Likely Cause
Timing drift in the sequenced flashing light controller, or a failed flasher unit, has broken the rolling flash pattern.
Diagnostic Steps
Verify controller timing against the specified sequence rate; check each flasher head in turn for correct firing order; inspect flasher control cabling for damage.
Corrective Action
Recalibrate or replace the SFL controller, or replace the faulty flasher head; confirm the rolling sequence is restored end to end.
Red Side-Row Bar Faded or Shifted Toward Orange
Likely Cause
UV exposure and thermal stress have degraded the red colour filter on a side-row bar, shifting its chromaticity out of tolerance.
Diagnostic Steps
Run a photometric/chromaticity check against ICAO colour limits for red; visually compare the suspect bar to a known-good reference fixture.
Corrective Action
Replace the red filter or lens assembly; re-verify chromaticity with a follow-up test before returning the bar to service.
CCR Trips on Overcurrent or Ground Fault
Likely Cause
Moisture ingress at a fixture or connector has degraded insulation resistance, creating a short or a partial ground fault on the series loop.
Diagnostic Steps
Megger the full circuit to identify the low-resistance segment; visually inspect suspect fixtures for cracked gaskets, condensation, or damaged secondary cable jackets.
Corrective Action
Dry out or replace the affected fixture/connector, renew O-rings and gaskets, and confirm insulation resistance is back above the acceptable minimum before re-energising.
Elevated / Side-Row Fixture Misaligned
Likely Cause
Wind loading, wildlife strike, or vehicle contact has knocked an elevated fixture or side-row bar off tolerance; side-row bars are especially sensitive since they must sit precisely relative to the centreline.
Diagnostic Steps
Re-check fixture aim with a theodolite or laser alignment system against the approach centreline; inspect the frangible coupling and mounting stake for cracking or play.
Corrective Action
Re-level and re-aim the fixture, replace the frangible coupling if fatigued, and address any base or subgrade settlement to prevent recurrence.
Reliability

Failure Modes & Root Causes

Steady-Burn Bar Light Source Failure
High Severity
Root Cause
Solder-joint fatigue from repeated thermal cycling, moisture ingress through a compromised LED board seal, or ordinary end-of-life lumen depreciation.
Effect
Single light or bar within the approach or side-row array goes dark or drops below minimum intensity while the rest of the array continues to operate normally.
Detection Method
Nighttime visual patrol along the approach centreline, periodic photometric intensity survey, and continuity/secondary-voltage checks at the fixture connector.
Isolating Transformer Winding Failure
High Severity
Root Cause
Moisture ingress leading to insulation breakdown, a manufacturing defect in the winding, or a blown primary fuse-wire link from a transient surge.
Effect
Open-circuit point in the series loop; can darken the single fixture or, if the open extends to the loop itself, take down the entire array or side-row bar circuit.
Detection Method
Megger test of the transformer, secondary voltage check with the CCR energised, and loop-resistance testing from the CCR output.
L-823 Connector / Splice Degradation
Medium Severity
Root Cause
Improper seating or crimping during installation, gasket failure allowing groundwater ingress, or corrosion building up on the pins over time.
Effect
Intermittent operation, flickering, or a partial ground fault that degrades circuit insulation resistance.
Detection Method
Insulation resistance (megger) testing of the circuit and visual inspection of connectors at each fixture base can during maintenance.
Series Cable Insulation Breakdown
High Severity
Root Cause
Cable jacket damage from nearby excavation or wildlife activity, age-related insulation degradation, or prolonged standing water in the duct run.
Effect
Ground fault or short circuit that trips the CCR or darkens the entire series loop feeding the approach, side-row, or decision bar circuits.
Detection Method
Full-circuit megger test to flag the low-resistance segment, followed by sectionalised testing or time-domain reflectometry to pinpoint the fault location.
Elevated / Side-Row Fixture Frangible Coupling Fatigue
Medium Severity
Root Cause
Cyclic wind loading, wildlife strike, or contact from a maintenance vehicle, combined with ordinary material fatigue over the service interval.
Effect
Fixture leans, loosens, or separates from its mounting stake, pulling the light out of aim tolerance and distorting the side-row or decision bar reference.
Detection Method
Physical inspection for cracking or play in the coupling, and periodic fixture-aim checks with a theodolite or laser alignment system.
CCR Regulation Fault
High Severity
Root Cause
Internal component failure (control board or output stage), a load mismatch after circuit modification, or a firmware/setpoint fault.
Effect
Incorrect brightness step, failure to hold regulated current across the loop, or nuisance tripping on an otherwise healthy circuit.
Detection Method
CCR self-diagnostic/fault indication, output current verification, and a load-bank test to confirm regulation across all intensity steps.
Red Filter / Lens Degradation (Decision Bar & Side-Row Bars)
Low Severity
Root Cause
Prolonged UV exposure and heat cycling causing the red filter material to fade, combined with grime build-up on the outer lens surface.
Effect
Red output on the decision bar or side-row bars fades or shifts toward orange, weakening the CAT II/III decision-height cue the bars are meant to provide.
Detection Method
Scheduled photometric colour and intensity testing against the required red chromaticity range, and visual inspection of filters during quarterly cleaning.
SFL Flasher / Condenser Discharge Unit Failure
High Severity
Root Cause
Ageing capacitor bank in the condenser discharge unit, a failed trigger transformer, or timing drift in the sequenced flashing light controller.
Effect
Individual flasher head fails to fire or fires out of sequence, breaking the rolling flash pattern that leads pilots visually down the approach centreline.
Detection Method
Verify controller timing against the specified sequence rate, check each flasher head in firing order, and inspect the condenser discharge unit for capacitor swelling or leakage.
Precautions

Safety & Operational Notes

Series Circuit Isolation
Electrical Safety

Centreline bar, crossbar, and red side row barrette circuits run on constant-current series loops that can carry several kV. De-energise and lock out the associated CCR, then verify zero energy at the tower base or barrette before opening any enclosure.

Sequenced Flasher Capacitor Discharge
Electrical Safety

Condenser discharge units driving the sequenced flashing lights store a high-energy charge even after the master flasher controller is switched off; discharge each unit through its bleed resistor and confirm zero voltage before servicing a flasher head.

Elevated Tower & Off-Runway Access
Personnel Safety

Light bar towers extend along the extended centreline over terrain that may be uneven, waterlogged, or off the paved movement area; use fall protection when climbing frangible towers and assess ground conditions before positioning vehicles or ladders.

Frangibility Not to Be Defeated
Mechanical

Never substitute a frangible coupling or tower base with a rigid fitting, and do not over-torque connections during installation or repair; the structure must still break away cleanly on aircraft impact within the runway safety area.

CAT II/III Airside Work Coordination
Operational

ALSF-2 supports lower-minima CAT II/III operations, so any bar, crossbar, or flasher taken out of service can affect published minima; obtain ATC/airside coordination and issue a NOTAM before starting work, and keep personnel and vehicles clear of the approach surface during aircraft operations.

FOD Control Along the Approach
Operational

Account for tools, fasteners, and hardware at every tower and barrette worked on, and remove or secure loose material before leaving the site, since debris in the approach area can be ingested or strike an aircraft on short final.

Insulation Test Before Re-Energisation
Electrical Safety

After any cable, connector, or transformer work on a bar, crossbar, red barrette, or flasher circuit, megger test the affected series loop before restoring power, since a residual fault can trip the CCR or damage healthy fixtures on the same circuit.

Restore to Compliant State
Compliance

Do not leave the system with a bar out of aim tolerance, a dark flasher, or an out-of-sequence discharge pattern; verify photometric output and flasher timing against CAT II/III requirements before closing out the work and cancelling the associated NOTAM.

Field Insight

Engineering & Expert Notes

Test Failover, Not Just Primary Power
Redundancy

CAT II/III operations depend on the standby power transfer actually completing within tolerance, not just on the standby source existing. Schedule live transfer tests under load rather than assuming a generator that starts on command will also switch over cleanly.

Red Side-Row Bars Need Their Own Fault Isolation
Electrical

Because the red side-row bars carry specific meaning about entering the critical final segment, a wiring topology where a single fault can dim both the side-row and centreline arrays defeats their purpose. Verify the loop segmentation keeps side-row and centreline faults independently detectable.

Side-Row Intensity Must Track the Centreline, Not Just Meet Minimums
Photometric

A side-row bar that individually passes its intensity minimum can still under-perform relative to the centreline barrettes it's meant to complement, weakening the visual cue at the exact point CAT II/III pilots need it most. Compare side-row to centreline readings, not just each against its own spec.

731m/914m of Elevated Structure Means 731m/914m of Settlement Risk
Structural

The full-length ALSF-2 array crosses more variable subgrade than shorter systems, so alignment drift is rarely uniform along its length. Survey in sections and compare year-over-year rather than spot-checking a handful of representative bars.

Correlate SFL Faults With Recent Weather, Not Just Maintenance History
Troubleshooting

In fog- and snow-prone environments, moisture-driven SFL controller faults often cluster after specific weather events rather than developing gradually. Cross-reference fault logs against weather records to catch a systemic ingress problem before it becomes a pattern of nuisance outages.

Keep CAT II/III Margin Documentation Audit-Ready
Compliance

Given how tightly CAT II/III operations are tied to demonstrated system reliability, incomplete or inconsistent intensity and availability records can jeopardise category approval independent of actual fixture condition. Standardise the survey and logging format across shifts and contractors.

Quick Answers

Frequently Asked Questions

Short answers about the ALSF-2 approach lighting system: how it differs from ALSF-1, side-row bars, decision bar, power and control, standards, testing, maintenance and common faults.

Q1What is the ALSF-2 approach lighting system?

ALSF-2 (Approach Lighting System with Sequenced Flashing lights, Category II/III) is a high-intensity precision approach lighting system for the most demanding low-visibility operations. It extends 731 m (2,400 ft), or 914 m (3,000 ft) on shallow-slope sites, from the threshold and includes the ALSF-1 features plus red side-row bars, a decision bar and higher-intensity sequenced flashing lights.

Q2What is the difference between ALSF-1 and ALSF-2?

ALSF-2 supports CAT II and III approaches rather than CAT I. It adds red side-row bars in the final 300 m, a decision bar at the decision height point, and higher-intensity sequenced flashing lights with a faster flash rate for fog penetration. It also uses automatic RVR-linked dimming and independent circuit sectors with duplicate isolating transformers so a single fault cannot take down the full array.

Q3What are the red side-row bars for?

Red side-row bars are installed on both sides of the approach path in the final 300 m. They give a visual warning if the aircraft deviates laterally from the centreline and help define the approach corridor. They are at least 2,000 cd red, with colour within ICAO Annex 14 boundaries.

Q4What is the decision bar on an ALSF-2?

The decision bar is a row of lights at the decision height point that gives the pilot a visual reference for the go/no-go decision. It should be verified at commissioning and checked semi-annually for correct illumination and intensity.

Q5Where is ALSF-2 used?

It is installed on precision approach runways with CAT II/III capability, major international hub airports needing reliable low-visibility operations, airports in regions with adverse weather such as fog, heavy rain and snow, military airbases supporting all-weather operations, and high-traffic runways where operational continuity is critical.

Q6How is ALSF-2 powered and controlled?

Steady-burning elements (barrettes, red side-row bars, centreline barrette and decision bar) run on independent constant current series circuits at 6.6 A in five steps from 2.8 A to 6.6 A, with each fixture fed through its own isolating transformer (100 W to 200 W). The ALCMS selects the step from RVR, ATC instruction or automatic visibility-linked logic. The high-intensity SFL are driven by capacitor-discharge units and a flasher controller at the faster CAT II/III sequence rate.

Q7What are the typical specifications of an ALSF-2?

Barrettes are spaced at 30 m (100 ft) along the full length, with white steady intensity of 10,000 to 20,000 cd and SFL peak effective intensity of at least 20,000 cd (higher-output units toward the CAT III end). Fixtures are IP67/IP68, use L-824 single-conductor cable rated 5 kV with L-823 connectors, and insulation resistance should be at least 50 MΩ measured cable-to-ground.

Q8Which standards apply to ALSF-2?

The main references are ICAO Annex 14, FAA AC 150/5345-46 (approach lighting components), IEC 61827 and FAA Engineering Brief #67 (LED ALSF-2 component performance), with isocandela figures per FAA AC 150/5340-30. Always verify the current edition and your aerodrome's approved requirements.

Q9How should an ALSF-2 be tested at commissioning?

Megger-test the steady-burning, high-intensity SFL and red side-row circuits separately before backfill, verify loop continuity and resistance for the full run, and check transformer secondary voltages with the CCR energised. Then simulate a range of RVR inputs to confirm automatic dimming steps correctly, confirm the SFL sequence and decision bar response, check alignment and colour segregation of the barrettes and red side-row lights, and run a photometric test against ICAO/FAA CAT II/III tolerances.

Q10How often should an ALSF-2 be inspected and maintained?

Typical intervals are quarterly for barrette and side-row lens cleaning, semi-annual for sequenced flasher timing, decision bar function and automatic dimming/CCR step verification, and annual for photometric intensity checks, seal and gasket inspection, insulation resistance tests, and cable and connector inspection. Your airport's approved maintenance programme takes precedence.

Q11Why has a red side-row bar faded or shifted toward orange?

UV exposure and thermal stress degrade the red colour filter over time, shifting its chromaticity out of tolerance. Run a photometric and chromaticity check against ICAO colour limits for red and compare the suspect bar with a known-good fixture. Replace the red filter or lens assembly and re-verify chromaticity before returning the bar to service.

Q12What safety precautions apply when working on ALSF-2?

Series loops can carry several kV, so de-energise and lock out the CCR and verify zero energy before opening any enclosure, and discharge the flasher capacitor units through their bleed resistors before servicing a flasher head. Keep frangible fittings frangible, megger-test the loop before re-energising, and obtain ATC/airside coordination and a NOTAM before taking a bar, side-row or flasher out of service. Do not leave the system with a bar out of aim tolerance or a dark flasher.

Go Further

Go Beyond the Component. Understand the Complete AGL System.

You have explored the component. Now understand how it works within the complete Airfield Ground Lighting system.

Learn AGL from fundamentals to design, installation, testing, photometry, commissioning, maintenance and troubleshooting through structured technical training at Precision AGL Academy.

Build practical knowledge. Understand the circuit. Read the standards. Troubleshoot with confidence.

Your next step in AGL starts here.

The Learning Pathway
Learn Understand Design Test Maintain Document Apply Certify

Need expert guidance on ALSF‑2 selection, installation, or upgrade?

Precision AGL Academy provides advice on CAT II/III compliance, SFL integration, intensity settings, and field testing of ALSF‑2 approach lighting systems.