A yellow sign with black text and symbols that provides non‑regulatory operational information to pilots and vehicle drivers on the airfield — for example radio frequencies, areas not visible from the tower, and noise abatement procedures. It is distinct from the black‑background/yellow‑text Location Sign (which identifies the taxiway or runway you are on) and the black‑background/white‑numeral Runway Distance Remaining Sign, both separate sign categories.

Information Sign

Image disclaimer: For identification and illustration only. It may show a product by another manufacturer and may not depict the exact item described; it is not a statement of any product’s quality, approval or performance. Third-party image and trademark rights belong to their owners. See full notice.

Overview

What Is It?

An Information Sign is a yellow rectangular sign with black text and symbols that gives pilots and vehicle operators operational information the airport operator determines they need at a given location — most commonly applicable radio frequencies, notice of areas not visible from the control tower, and noise abatement procedures. Unlike mandatory instruction signs (red/white), information signs are advisory rather than regulatory. They are a distinct FAA/ICAO sign category from Location Signs (black background, yellow text, used to confirm which taxiway or runway you are currently on) and Runway Distance Remaining Signs (black background, white numerals) — both of which happen to share elements of the same surface-movement guidance role but carry different information under different colour codes.

Purpose

Purpose & Function

The information sign exists for the specific, narrower set of operational notices that don't fit any of the airfield's other sign categories: applicable radio frequencies, the location of areas not visible from the control tower, noise abatement procedures, and similar advisories the airport operator determines pilots or drivers need at a given point. Its yellow-on-black colour scheme signals that the content is advisory rather than regulatory, the same way a red mandatory instruction sign signals a binding obligation — but that colour is shared with several other non-mandatory sign types (location, direction, destination signs), so the legend itself, not just the colour, is what tells a pilot which of those categories they're reading.

Application

Where Is It Used?

Installed wherever the airport operator determines pilots or vehicle drivers need an operational notice that isn't covered by a mandatory, location, direction, or destination sign — typically near an area not visible from the tower, at a point where a specific radio frequency applies, or where noise abatement procedures need to be flagged. They are placed at a height of 1.5 to 2 metres above the pavement, on frangible supports. Because their use is discretionary rather than mandated at every such location, information signs are more variable in number and placement between airports than the other sign categories.

Placement

Installation & Location

Posts are founded at the specific point the notice applies to — the edge of an area not visible from the tower, a taxiway segment with a distinct radio frequency, or a location affected by noise abatement procedures — set back clear of wingtip clearance for that location's design aircraft, with orientation set out so the panel is read squarely by traffic approaching from the intended direction. Because siting is driven by where the airport operator has identified a need rather than by a fixed geometric rule tied to every intersection, setout is agreed with airfield operations on a case-by-case basis. Illuminated panels are cabled from the nearest taxiway or runway lighting distribution point; retroreflective panels need only the foundation and fixing.

Function

How Does It Work?

The sign displays black text (and occasionally a symbol) on a yellow background, following ICAO Annex 14 and FAA AIM 2-3-12 conventions. Unlike direction or destination signs, an information sign does not carry a directional arrow — it states a fact or notice rather than pointing somewhere. The sign is either non‑illuminated (using retroreflective sheeting) or internally illuminated (LED or fluorescent) for nighttime visibility. The information is presented in a clear, standardized format that is legible from a distance. The sign is mounted on a frangible or breakaway support to minimize aircraft damage in case of collision.

Architecture

System Architecture & Control Logic

Information signs sit on one of two very different control models depending on their illumination type. An internally illuminated sign (LED or fluorescent panel) is wired onto the constant current series circuit for that section of taxiway: an ALCMS selects the required brightness step from RVR or ATC input, the CCR regulates the entire loop to a fixed current, and the sign's panel — fed through its own isolating transformer — burns at the same intensity as every other fixture sharing that loop. A fault is detected the same way as for any other AGL fixture: a voltage rise at constant current flags an open circuit or failed transformer as a loop-level fault, not a fault isolated to the sign itself. A non-illuminated sign using retroreflective sheeting has no electrical control path whatsoever — its legibility depends entirely on the sheeting reflecting an aircraft's or vehicle's landing lights back toward the source, so there is no ALCMS command, no CCR current, and nothing for the control system to monitor or fault-detect on that sign.

Illuminated variant: ALCMS → CCR → Loop → Sign Panel. Retroreflective variant: no electrical path at all.

ILLUMINATED VARIANT RETROREFLECTIVE VARIANT ALCMS Selects brightness step (RVR / ATC) AIRCRAFT / VEHICLE LANDING LIGHTS External light source, not airfield-commanded CONSTANT CURRENT REGULATOR Converts step command to fixed loop current RETROREFLECTIVE SHEETING Prismatic / glass-bead material on the sign face ISOLATING TRANSFORMER + TAXIWAY LOOP Sign shares the loop with adjacent AGL fixtures NO POWER, NO LOOP, NO ALCMS Passive material — nothing to command or monitor INTERNALLY-ILLUMINATED SIGN PANEL LED or fluorescent, stepped with the loop current BEAM REFLECTED BACK TO SOURCE Bright return along the incoming light path SAME MESSAGE READ BY THE PILOT Colour, symbol and text are identical either way ONLY THE ILLUMINATED VARIANT IS UNDER ALCMS / CCR CONTROL
System Logic

What Kind of Information It Carries

Category
Advisory, Not Mandatory
Yellow/black — unlike a red Mandatory Instruction Sign, nothing here compels a stop
Purpose
Operational Notice
Tells the pilot or driver something they need to know, not where they are or what they must do
Radio Frequency
Applicable Frequency
Posted where a non-obvious or localized frequency applies
Tower Visibility
Area Not Visible From Tower
Flags a blind spot in the controller's sightline
Noise Abatement
Procedure Notice
Posted where a noise abatement procedure applies
Other Local Notice
Operator-Determined
Any other advisory the airport operator judges necessary
These fall under the FAA/ICAO "Information Sign" category specifically — distinct from a Location Sign (black background, yellow text, confirms which taxiway or runway you're on) or a Runway Distance Remaining Sign (black background, white numerals), both of which share the surface-movement guidance role but are separate, differently-coloured sign types.
Construction

Physical Construction

The panel is an extruded aluminium frame carrying a Class 1/2 retroreflective face with the legend cut in black on yellow, or a translucent acrylic panel with the legend as a perforated film backlit by an internal LED module where the site calls for illumination. Because the message here is advisory rather than mandatory, the frame and legend colours follow the yellow/black information format rather than the red/white treatment reserved for instruction signs, letting a pilot distinguish the two families at a glance before reading the text itself. The frame is gasket-sealed to an IP65 rating and mounted on a frangible coupling and below-grade base plate so it shears away cleanly on impact.

Specification

Technical Parameters

ParameterTypical Value
ColourYellow background, black text (ICAO / FAA)
Dimensions1.2 m × 0.6 m (typical) or as per site requirements
Text Height150–200 mm (depending on viewing distance)
IlluminationNon‑illuminated (retroreflective) or internally illuminated (LED)
Retroreflective ClassClass 1 or Class 2 (ASTM D4956)
Mounting Height1.5–2 m above pavement
Frangible SupportBreakaway coupling or frangible post
Protection ClassIP65 (weatherproof)
Operating Temperature-40°C to +60°C
Power Supply

Electrical Requirements

RequirementTypical Value
Circuit TypeSeries circuit, constant current (CCR fed) — illuminated variant only
Rated Series Current6.6A (3 to 5-step: 2.8A / 3.4A / 4.1A / 5.2A / 6.6A)
IsolationVia dedicated isolating transformer, not directly connected to series loop
Transformer SecondaryMatched to sign wattage; sized to series circuit rating
Cable TypeL-824 single-conductor, direct-burial rated, 5kV or 600V per circuit design
ConnectorL-823 primary connector, submersible-rated splice
Insulation Resistance≥ 50 MΩ (megger test, cable-to-ground)
Earthing/GroundingSign body and base can bonded to airfield earth grid
Fault ProtectionCCR-level ground fault and open-circuit detection
Non-Illuminated VariantNo electrical supply required — passive retroreflective panel only
Optical Performance

Photometric Requirements

ParameterTypical Value
Background Luminance (Yellow)≥ 30 cd/m² average (illuminated variant), uniformity ratio ≤ 10:1 (max:min)
Legend Contrast (Black)Opaque legend masking against the illuminated yellow background; contrast ratio ≥ 5:1
Retroreflective Coefficient (Non-Illuminated Variant)RA ≥ 20 cd/lux/m² (yellow) per ASTM D4956 Class 1/2
Chromaticity (Yellow Background)Within ICAO Annex 14 aeronautical yellow boundary (CIE coordinates)
Viewing Angle± 5° horizontal, legible from typical cockpit eye height
Luminance Tolerance± 25% of rated value across the panel face
Maintenance Factor≥ 50% of new-panel luminance before lamp/LED or sheeting replacement is due
Test MethodLuminance meter/photometer at normal and oblique angles, or retroreflectometer for the non-illuminated variant
Compliance

Applicable Standards

ICAO Annex 14

Information sign colours, dimensions, and placement

FAA AC 150/5340-18

Standards for Airport Sign Systems — siting, design, and colour convention for this sign type

FAA AC 150/5345-44

Equipment/fixture specification for the sign unit itself (siting, design and colour are governed by AC 150/5340-18 above)

ASTM D4956

Retroreflective sheeting performance standards

IEC 60598

Luminaire requirements for illuminated signs

Prerequisites

Installation Requirements

Setting-Out & Siting Survey
Civil

Survey and mark the sign position from the design/siting drawing before excavation, confirming clearance from the taxiway/runway edge safety area and any frangibility height limit.

Foundation / Base Plate Installation
Civil

Excavate and set the base plate or footing to design depth, keeping the finished mount level and within the frangible height limit for the sign's location.

Frangible Mount Fitting
Mechanical

Fit the frangible post or breakaway coupling and torque to the specified value, confirming it shears as designed under lateral load and does not bind.

Cable Route & Connector Termination
Electrical

Where the sign is internally illuminated, lay the duct/cable route to the panel and terminate the L-823 connector per manufacturer procedure, keeping the splice fully submersible-rated before backfill.

Isolating Transformer Matching
Electrical

Where the sign is internally illuminated, confirm the isolating transformer wattage and ratio match the panel and the series circuit's rated current step before connection.

Panel Legend & Content Setting
Quality

Before the panel is fixed and the position closed out, confirm the frequency, notice, or advisory text on the panel matches the airfield signage schedule for that location.

Retroreflective Sheeting Application
Mechanical

Apply and inspect the retroreflective sheeting for correct grade, alignment, and freedom from bubbles or edge lifting before the panel is mounted.

Pre-Backfill Sign-off
Documentation

Record base/footing position, frangible coupling torque, cable route, and panel content as-built before backfill, since these are not inspectable once the site is closed.

Verification

Testing & Commissioning

Insulation Resistance (Megger) Test
Pre-Energisation

Where the sign is internally illuminated, megger-test the isolating transformer and internal wiring before the circuit is energised, confirming insulation resistance clears the acceptable minimum ahead of backfill.

Loop Continuity & Resistance Test
Pre-Energisation

For an illuminated installation, verify series loop continuity through the sign and record loop resistance, ruling out open circuits or high-resistance splices before first energisation.

Primary/Secondary Voltage Verification
Energisation

With the CCR energised, confirm secondary voltage at the illuminated sign's L-823 connector matches the transformer's rated ratio at the commissioned current step.

CCR Brightness Step Response
Energisation

Cycle the CCR through every intensity step and confirm an illuminated panel responds correctly at each, ruling out a marginal transformer or a loose connection.

Retroreflectivity / Luminance Verification
Final Acceptance

Measure sheeting retroreflectivity with a retroreflectometer against ICAO/FAA commissioning minimums; where the panel is internally illuminated, also verify luminance and colour uniformity with a luminance meter.

Legend & Content Verification
Final Acceptance

Confirm the frequency, notice, or advisory text on the panel matches the airfield signage schedule for that location.

Frangible Coupling & Mounting Verification
Pre-Energisation

Confirm the frangible coupling, base depth, and panel height meet as-built tolerances before the site is finally backfilled.

Documentation & As-Built Sign-off
Final Acceptance

Record retroreflectivity/luminance readings, and (where illuminated) insulation, continuity, and voltage readings, alongside as-built position in the commissioning dossier for handover.

Upkeep

Inspection & Maintenance

Retroreflectivity Check
Annual

Measure sheeting retroreflectivity with a retroreflectometer against ICAO / FAA minimums, and budget for sheeting replacement roughly every 5–7 years.

Illumination System Test
Annual

Test internal LED or fluorescent illumination for uniform, even lighting so the sign remains legible at night, especially ahead of low-visibility seasons.

Frangible Coupling Inspection
Annual

Check the coupling or post for brittleness or corrosion and replace per manufacturer schedule to preserve breakaway performance on impact.

Seal & Cable Gland Check
Annual

Inspect housing seals and cable glands for degradation, since moisture ingress through damaged seals is a leading cause of corrosion and electrical faults.

Sign Face Cleaning
Quarterly

Clean dirt, de-icing fluid residue, and rubber deposits off the sign face to keep both reflectivity and legibility within spec.

Insulation Resistance Test
Annual

Megger-test internal wiring and any isolating transformer to confirm insulation resistance stays above minimum, catching moisture ingress early.

Field Notes

Common Field Issues

Retroreflective Sheeting Degradation

UV exposure, weathering, and abrasion can reduce reflectivity. Regular inspection and replacement (typically every 5–7 years) is recommended.

Internal Illumination Failure

LED or fluorescent lighting can fail, reducing nighttime legibility. Regular testing of the illumination system is essential.

Frangible Support Fatigue

Breakaway couplings can become brittle over time. Regular inspection and replacement as per manufacturer guidelines are required.

Moisture Ingress

Water ingress through seals can cause corrosion and electrical faults. Routine seal checks and use of desiccants are recommended.

Diagnostics

Troubleshooting Guide

Legend Unreadable at Night, Fine by Day
Likely Cause
Retroreflective sheeting has degraded past its useful reflectivity, or (on an illuminated sign) the internal lighting has failed or dimmed.
Diagnostic Steps
Take a night or low-light reflectivity/luminance reading against the applicable ICAO/FAA minimum; on illuminated signs, confirm supply voltage is present at the fixture before condemning the lamp or LED module.
Corrective Action
Replace the retroreflective face panel if sheeting is below minimum, or swap the LED module/lamp if illumination has failed; re-verify with a follow-up reading.
Illuminated Sign Dark or Flickering
Likely Cause
Failed LED module or fluorescent lamp, a loose/corroded cable connection at the base can, or an upstream circuit fault feeding the sign.
Diagnostic Steps
Check for supply voltage at the sign's connector; inspect and re-torque cable terminations; if voltage is present but the sign stays dark, isolate the lamp/LED module.
Corrective Action
Replace the failed lamp or LED module, or re-terminate corroded connections with fresh crimps and sealant; confirm the upstream circuit if no voltage reaches the sign.
Moisture or Condensation Inside Housing
Likely Cause
Failed gasket or seal at the frame or cable entry, allowing water ingress and risking corrosion of internal electrical contacts.
Diagnostic Steps
Inspect gaskets and cable glands for cracking or compression set; check for visible condensation or staining inside the housing; verify desiccant (if fitted) hasn't saturated.
Corrective Action
Replace failed gaskets and cable glands, dry out the housing, refresh or add desiccant, and re-check for recurrence at the next inspection interval.
Sign Leaning, Loose, or Misaligned
Likely Cause
Frangible coupling has fatigued or partially sheared, or the base plate/subgrade has settled, shifting the sign out of its correct orientation.
Diagnostic Steps
Visually and physically check the frangible coupling for cracking or play; confirm the sign face is still square and legible from the intended approach; inspect the base plate and surrounding pavement for settlement.
Corrective Action
Replace the frangible coupling on schedule if fatigued, re-level and re-orient the sign, and address any base plate or subgrade settlement to prevent recurrence.
Reliability

Failure Modes & Root Causes

LED Panel / Internal Light Source Failure
High Severity
Root Cause
Thermal cycling or driver-circuit fault in the LED panel of an illuminated unit, or a manufacturing defect in the light source.
Effect
Sign face goes dark or dim on the illuminated variant, removing the sign's night/low-visibility conspicuity while the panel itself remains structurally intact.
Detection Method
Night or low-light visual check against the panel's expected output, and driver-circuit voltage check at the housing.
Retroreflective Sheeting Degradation
Medium Severity
Root Cause
UV exposure, surface abrasion, or accumulated grime/rubber film reducing the sheeting's coefficient of retroreflection over time.
Effect
Reduced legibility under aircraft or vehicle landing-light illumination at night, most critical for non-illuminated units that depend entirely on retroreflectivity for visibility.
Detection Method
Scheduled retroreflectivity measurement against ICAO Annex 14 / FAA minimums, and visual inspection for sheeting delamination or contamination.
Frangible Coupling Fatigue / Impact Damage
High Severity
Root Cause
Cyclic wind loading fatiguing the frangible coupling over time, or a direct strike from a vehicle, aircraft component, or ground equipment.
Effect
Sign leans, misaligns, or separates from its post, degrading legibility and, if debris remains in the movement area, creating a foreign-object hazard.
Detection Method
Post alignment and coupling condition check during scheduled inspection, and immediate post-incident inspection following any reported strike.
Power/Circuit Connector Degradation
Medium Severity
Root Cause
Moisture ingress at the base can, gasket, or connector feeding an illuminated unit, or a corroded/loose termination from age.
Effect
Intermittent illumination or a partial ground fault on the feeding circuit, affecting the illuminated unit's reliability independent of the panel itself.
Detection Method
Insulation resistance (megger) testing of the feeder circuit, and visual inspection of the base can, gasket, and connector during maintenance.
Legend Mismatch After an Operational Change
Medium Severity
Root Cause
Radio frequency, noise abatement procedure, or other advisory legend on the sign face not updated to match a subsequent operational change.
Effect
Sign displays a notice that no longer matches current operating procedure, potentially sending a pilot or driver to the wrong frequency or an outdated procedure.
Detection Method
Cross-check of information sign legends against current airfield operational records whenever a change is implemented.
Precautions

Safety & Operational Notes

Circuit Isolation Before Access
Electrical Safety

De-energise and lock out the feeder circuit at the CCR or panel, then verify zero energy at the base can before opening the housing or handling cable connectors.

Airside Work Coordination
Operational

Any work on or near the movement area requires ATC/airside coordination and a NOTAM where the sign will be dark, obscured, or out of tolerance, with vehicle and personnel movement kept clear of the taxiway or runway strip per the aerodrome's safety management procedures.

Frangibility Not to Be Defeated
Mechanical

Never substitute the frangible coupling with a rigid fitting or over-torque it during installation or repair; the coupling must still shear cleanly on aircraft impact to limit damage under the frangibility requirement.

FOD Control at the Base
Operational

Keep tools, fasteners, and removed gaskets accounted for at all times when the base can or housing is open, and secure or remove any loose material before reinstating the sign, to prevent foreign object debris on the movement area.

Insulation Test Before Re-Energisation
Electrical Safety

After any cable, connector, or panel work, megger test the affected circuit before restoring power, since a residual fault at re-energisation can trip the feeder circuit or damage healthy units on the same loop.

PPE & Grounding
Personnel Safety

Use insulated tools and appropriate PPE when working on circuit connections, and confirm the sign housing and base can are bonded/grounded per the electrical design before reconnecting the circuit.

Legend Accuracy Verification
Operational

After any change to the operational notice it displays (frequency, noise abatement procedure, or similar), cross-check the sign's legend against the current airfield operational records before signing off the work as complete.

Field Insight

Engineering & Expert Notes

Confirm What Category of Information Before Setting Repair Priority
Operational

An information sign's content — a frequency, a tower blind-spot warning, a noise abatement notice — varies by site; triage repair urgency by what the sign is actually displaying at that location, not by a blanket "information sign" label.

Schedule an Explicit Content Audit Rather Than Relying on Incidental Reports
Maintenance

Because these signs serve varied, non-regulatory purposes, content drift is easy to miss — it's less likely to be caught the way a gate or stand-number mismatch gets reported. Put a periodic content audit on the schedule directly.

Follow the Same Fault-Diagnosis Chain Regardless of Message Type
Troubleshooting

Voltage at the connector, then driver, then LED module — that diagnostic order applies regardless of what notice the sign displays. Don't skip steps just because the sign feels lower-stakes.

Environmental Exposure Doesn't Care About Regulatory Status
Durability

UV and de-icing fluid degrade an information sign's face on the same physical timeline as a mandatory instruction sign. Track face condition on the same inspection schedule even if repair priority differs.

Confirm the Sign's Purpose Before Reprinting Its Legend
Operational

Before altering text on an information sign, confirm with airfield operations exactly which notice it is displaying and why — a frequency, a tower blind-spot warning, or a noise abatement procedure each has a different update trigger and approving authority.

Frangibility and Setback Rules Don't Relax for “Just Information”
Mechanical

Apply the same frangible-coupling and clearance requirements as any other airfield sign — a non-regulatory message doesn't reduce the mechanical hazard the sign poses if struck.

Quick Answers

Frequently Asked Questions

Short answers about the information sign: purpose, siting, power, standards, maintenance and common faults.

Q1What is an airfield information sign?

An information sign is a yellow rectangular sign with black text and symbols that gives pilots and vehicle operators operational information the airport operator determines they need at a location, most commonly applicable radio frequencies, areas not visible from the control tower, and noise abatement procedures.

Q2Is an information sign mandatory or advisory?

Advisory. Unlike red-and-white mandatory instruction signs, information signs are not regulatory, and their use is discretionary rather than mandated at every such location.

Q3How is an information sign different from a location sign or a distance remaining sign?

An information sign (black on yellow, no arrow) states a fact or notice. A location sign (yellow text on a black background) confirms which taxiway or runway you are on, and a distance remaining sign (white numeral on black) shows runway length left. They are separate FAA/ICAO sign categories.

Q4Where are information signs installed?

Wherever the airport operator decides an operational notice is needed that a mandatory, location, direction or destination sign does not cover, typically near an area not visible from the tower, where a specific radio frequency applies, or where noise abatement procedures need flagging. They stand 1.5 to 2 metres above the pavement on frangible supports.

Q5How is an illuminated information sign powered?

An illuminated information sign is wired onto the constant current series circuit for its section of the airfield and fed through its own isolating transformer rather than directly from the loop. The Constant Current Regulator (CCR) holds the loop at a fixed current (up to 6.6 A, with steps of 2.8, 3.4, 4.1, 5.2 and 6.6 A) and the ALCMS selects the brightness step, so the sign burns at the same intensity as the other fixtures on that loop. The non-illuminated variant is a passive retroreflective panel with no electrical supply.

Q6Which standards apply to information signs?

ICAO Annex 14 covers colours, dimensions and placement, with FAA AIM 2-3-12 conventions, and FAA AC 150/5340-18 covers siting, design and colour convention. FAA AC 150/5345-44 is the equipment specification for the sign unit, ASTM D4956 sets retroreflective sheeting performance, and IEC 60598 covers luminaires for illuminated signs.

Q7What are the photometric requirements for an information sign?

On the illuminated variant the yellow background should average at least 30 cd/m² (uniformity no worse than 10:1) with an opaque black legend giving a contrast ratio of at least 5:1. The non-illuminated variant needs a retroreflective coefficient of at least 20 cd/lux/m² for yellow per ASTM D4956 Class 1 or 2.

Q8Why is an information sign mounted on a frangible support?

The panel sits on a frangible post or breakaway coupling so that it breaks away if an aircraft strikes it, limiting damage to the aircraft. The coupling can turn brittle from weather and vibration, so it is inspected annually and replaced to the manufacturer's schedule to preserve its breakaway performance.

Q9How often should information signs be inspected and maintained?

Typical intervals are quarterly for cleaning dirt, de-icing fluid residue and rubber deposits off the sign face, and annual for retroreflectivity measurement, illumination testing, frangible coupling inspection, seal and cable gland checks, and insulation resistance (megger) testing. Retroreflective sheeting is usually budgeted for replacement every 5 to 7 years.

Q10What are the common field issues with information signs?

Four issues recur: retroreflective sheeting degradation from UV, weathering and abrasion (replacement is typically due every 5 to 7 years); failure of the internal LED illumination, which cuts night visibility; frangible support fatigue, as breakaway couplings turn brittle with weather and vibration; and moisture ingress through damaged seals or cable glands, which causes corrosion and electrical faults. Routine seal checks and desiccants are recommended. A legend that no longer matches after an operational change is also a listed failure mode.

Go Further

Go Beyond the Component. Understand the Complete AGL System.

You have explored the component. Now understand how it works within the complete Airfield Ground Lighting system.

Learn AGL from fundamentals to design, installation, testing, photometry, commissioning, maintenance and troubleshooting through structured technical training at Precision AGL Academy.

Build practical knowledge. Understand the circuit. Read the standards. Troubleshoot with confidence.

Your next step in AGL starts here.

The Learning Pathway
Learn Understand Design Test Maintain Document Apply Certify

Need expert advice on information sign selection or placement?

Precision AGL Academy provides guidance on sign design, illumination, and compliance with ICAO and FAA requirements.