MALS
A medium‑intensity approach lighting system for non‑precision runways, typically featuring a configuration of light bars extending 427 metres (1,400 ft) from the runway threshold. MALS provides enhanced visual guidance compared to basic SALS/SSALS, offering improved lateral and distance reference for pilots during night and marginal weather operations, while remaining simpler and more cost‑effective than precision systems like ALSF.
Image disclaimer: For identification and illustration only. It may show a product by another manufacturer and may not depict the exact item described; it is not a statement of any product’s quality, approval or performance. Third-party image and trademark rights belong to their owners. See full notice.
What Is It?
MALS (Medium Intensity Approach Lighting System) is a non‑precision approach lighting system that provides enhanced visual guidance for pilots during final approach. It typically consists of seven five-light bars spaced at 61m (200 ft) intervals extending 427 metres (1,400 ft) from the runway threshold, with a single crossbar (two wing bars) at the 305m (1,000 ft) point. MALS offers greater intensity and improved visibility compared to basic SALS, making it suitable for airports with higher traffic volumes or more demanding weather conditions. Unlike precision systems (ALSF‑1/2), MALS does not include sequenced flashing lights, but it provides a robust visual centreline and distance reference for night and marginal VFR operations.
Purpose & Function
MALS exists to give airports with meaningful traffic volume or more demanding weather a stronger visual approach reference than a basic single row of lights can provide, without introducing the sequenced flashing components that come with additional cost and complexity. Its optional crossbars at intermediate points add a depth and lateral reference along the row, letting a pilot judge distance and alignment more precisely than a plain unbroken line would allow, while stopping short of the dynamic directional cues that RAIL or SFL provide in the MALSR/MALSF variants. Its purpose sits deliberately between the most basic SALS-class systems and the flashing-augmented MALSR/MALSF configurations, offering airports a middle-tier upgrade path matched to their actual traffic and visibility demands.
Where Is It Used?
MALS systems are installed at airports that support non‑precision approaches but require enhanced visual guidance. They are typically used on:
- Non‑precision runways with higher traffic volumes or more demanding weather conditions
- Regional airports serving commercial turboprop and regional jet operations
- Military airfields where basic approach lighting is insufficient
- Runways with moderate approach speeds where longer lead‑in is beneficial
- Airfields transitioning from basic to enhanced lighting without the cost of precision systems
- Locations where terrain or obstacles require improved visual reference
Installation & Location
Fixtures are set out on lightweight frangible stands along the extended runway centreline at the standard 61 m (200 ft) spacing, running from the threshold out to 427 m (1,400 ft). A single crossbar stand pair is placed laterally at the 305 m (1,000 ft) point. Because MALS carries no sequenced flashing lights, the array is typically fed from a single steady-burning series circuit, with cable run in duct from each stand back to the regulator vault. Stands are sized for the lower loads of a medium-intensity system, and elevated piers are used only where the extended centreline crosses a road, ditch, or other minor obstacle. Setting-out is tied to the runway centreline extended and threshold survey.
How Does It Work?
The MALS system provides enhanced visual guidance through a combination of features:
- Single Row of Lights: Seven five-light bars, steady‑burning white, spaced at 61m (200 ft) intervals, extend from the runway threshold out to 427 metres (1,400 ft), providing a visual centreline reference.
- Crossbar Lights (Optional): A single crossbar (two five-light wing bars, one either side of the centreline bar) is located 305m (1,000 ft) from the threshold to provide distance reference and improve depth perception.
- Medium Intensity: Higher intensity than basic SALS, with better visibility in marginal weather and brighter ambient light conditions.
- Lateral Guidance: The row of lights helps the pilot align the aircraft with the runway centreline during the final approach segment.
- Distance Reference: The spacing of the lights and optional crossbars provides a rough distance reference, helping the pilot judge the approach path.
- Intensity Control: The lights are typically controlled by a CCR with intensity steps (usually 5‑step), allowing the ATC to adjust brightness for visibility conditions.
- Simplicity: The system has no flashing lights or complex sequencing, making it simpler and more reliable than precision systems.
System Architecture & Control Logic
MALS runs on a single series circuit loop, with no sequencer or flasher stage to coordinate — the centreline row and, where fitted, the crossbar lights are all wired into the same loop and therefore switch and dim together as one system. An Airfield Lighting Control and Monitoring System (ALCMS), operated by the tower or an automated visibility-linked routine, selects the required brightness step; this command is passed to the CCR, which regulates the entire MALS loop to the corresponding fixed current. Every fixture on the loop, centreline or crossbar, draws from the same current via its own isolating transformer and therefore burns at the same intensity simultaneously — there is no independent control of the crossbars or of any individual light along the row. Because MALS has no flashing stage, its control logic is the simplest of the approach lighting family: one command, one loop, one intensity for the whole array. Fault detection follows the same loop-based principle used across the AGL series circuit family: the CCR continuously monitors loop voltage against the commanded current, and a voltage rise at constant current signals increased circuit impedance, typically an open-circuit lamp or a failed isolating transformer, reported to the ALCMS as a loop fault rather than pinpointed to an exact fixture without further sectionalised testing.
ALCMS → CCR → MALS Series Circuit Loop (Row + Crossbar) → Isolating Transformer → Fixture (with loop-level feedback)
Row & Crossbar Overview
MALS carries seven steady-white light bars locked to a flat 61m (200 ft) spacing over the full 427m (1,400 ft) FAA length, rather than a single continuous row. The real functional addition is the single crossbar at 305m (1,000 ft) — two five-light wing bars either side of the centreline bar that give the pilot a depth-perception reference the row alone can't provide.
Physical Construction
Each light stand is a frangible aluminium or composite pole bolted to a shallow concrete footing or ground screw anchor, sized to break away cleanly if struck while still holding the fixture head steady in wind. The fixture head is a die-cast aluminium housing containing an LED array or 100–200W halogen lamp behind a toughened lens, gasket-sealed to achieve an IP67/IP68 rating, mounted so the beam projects uni-directionally toward the approach. Where the optional crossbar is fitted, three to five fixture heads are ganged on a rigid horizontal bar carried on its own pair of frangible stands, wired as a branch off the same series circuit as the centreline row. Internal wiring runs to L-823 primary connectors sealed for direct burial, terminating at the isolating transformer housed at the base of each stand or in a nearby ground box, with cable run in duct back to the regulator vault. Stainless-steel fasteners and corrosion-resistant coatings are used throughout to withstand prolonged outdoor exposure over unprepared or unpaved approach terrain.
Technical Parameters
| Parameter | Typical Value |
|---|---|
| System Type | Medium Intensity Approach Lighting System (MALS) |
| Light Source | LED array or halogen (100W – 200W) |
| Colour | White (steady‑burning) |
| Configuration Length | 427 metres / 1,400 ft (FAA standard) |
| Light Spacing | 61m / 200 ft intervals (seven 5-light bars) |
| Crossbar Lights | Single crossbar at 305m / 1,000 ft (two 5-light wing bars) |
| Flashing | None (steady‑burning only) |
| Intensity Steps | 5‑step CCR controlled (2.8A – 6.6A) |
| Beam Pattern | Uni‑directional towards approach |
| Mounting Type | Elevated or flush‑mounted (inset) |
| Isolating Transformer | 100W – 200W (6.6A series circuit) |
| Protection Class | IP67 / IP68 (submersible) |
| Support | Non‑precision approaches (VOR, NDB, GPS) |
Electrical Requirements
| Requirement | Typical Value |
|---|---|
| Circuit Type | Series circuit, constant current (CCR fed) |
| Rated Series Current | 6.6A (5-step: 2.8A / 3.4A / 4.1A / 5.2A / 6.6A) |
| Isolation | Via dedicated isolating transformer (100W – 200W), not directly connected to series loop |
| Transformer Secondary | Matched to fixture wattage; sized to series circuit rating |
| Cable Type | L-824 single-conductor, direct-burial rated, 5kV or 600V per circuit design |
| Connector | L-823 primary connector, submersible-rated splice |
| Insulation Resistance | ≥ 50 MΩ (megger test, cable-to-ground) |
| Earthing/Grounding | Fixture body and base can bonded to airfield earth grid |
| Fault Protection | CCR-level ground fault and open-circuit detection |
| Power Source | CCR output, regulated per ICAO/FAA intensity step schedule |
Photometric Requirements
| Parameter | Typical Value |
|---|---|
| Centreline Bar Intensity | 1,500 – 10,000 cd (white, medium intensity), 3 to 5-step |
| Intensity Steps | 100% / 30% / 10% / 3% / 1% of rated peak intensity |
| Vertical Beam Spread | Main beam 1°–12° above horizontal (peak ~2°–3°) |
| Horizontal Beam Spread | ± 4.5° either side of runway centreline extended |
| Chromaticity | White within ICAO Annex 14 boundary |
| Maintenance Factor | ≥ 50% of new-fixture intensity before replacement/cleaning is due |
| Intensity Tolerance | ± 25% of rated value at each CCR step (field measurement) |
| Isocandela Distribution | Per ICAO Annex 14 Attachment A / FAA AC 150/5340-30 MALS configuration figures |
| Test Method | Mobile photometric van/goniophotometer or fixed test bench per fixture |
Applicable Standards
ICAO Annex 14
MALS configuration, spacing, and photometric requirements
FAA AC 150/5345-46
Specification for MALS components
IEC 61827
Electrical and photometric performance for AGL luminaires
FAA Engineering Brief #67
LED MALS component performance requirements
Installation Requirements
Frangible Stand Footing
CivilSet each centreline stand footing at the standard 61 m (200 ft) spacing out to 427 m (1,400 ft), sized for the lighter loads of a medium-intensity system.
Elevated Piers at Minor Obstacles
CivilInstall piers only where the extended centreline crosses a road, ditch, or other minor obstacle, since most of the run needs no special foundation work.
Duct & Cable Route
ElectricalLay the duct run from each stand back to the regulator vault, sized for a single steady-burning series circuit with no separate flasher loop to route.
L-823 Connector Termination
ElectricalTerminate and seal the primary connector at each stand per manufacturer procedure, keeping every splice fully submersible-rated before backfill.
Isolating Transformer Matching
ElectricalConfirm each fixture's isolating transformer wattage matches the series circuit's rated current step before connection.
Stand & Optional Crossbar Assembly
MechanicalFix the fixture head to each frangible stand, and where included, assemble the crossbar on its own pair of stands, torquing all fittings to spec.
Setting-Out to Extended Centreline
MechanicalTie stand positions to the extended runway centreline and threshold survey so the row stays true from the threshold out to 427 m (1,400 ft).
Pre-Energisation Sign-off
DocumentationRecord stand positions, cable route, connector seals, and torque values as-built before backfill, since these are not inspectable once the site is closed.
Testing & Commissioning
Insulation Resistance (Megger) Test
Pre-EnergisationMegger-test the steady-burning series circuit before backfill, confirming insulation resistance clears the acceptable minimum ahead of first energisation.
Loop Continuity & Resistance Test
Pre-EnergisationVerify series loop continuity and record total loop resistance for every light along the full 427m (1,400 ft) run, including the crossbar, before first energisation.
Primary/Secondary Voltage Verification
EnergisationWith the CCR energised, confirm secondary voltage at each light's isolating transformer matches the rated ratio at the commissioned current step.
CCR Brightness Step Response
EnergisationCycle the CCR through every intensity step and confirm the row and any crossbars respond correctly, ruling out marginal transformers or loose connections.
Crossbar Alignment Verification
Final AcceptanceWhere crossbars are fitted at 150m, 300m, 450m, or 600m, check their lateral extent and alignment against the design layout, correcting any deviation before sign-off.
Light Row Alignment & Aim Verification
Final AcceptanceCheck spacing, elevation, and azimuth of each light along the 30m-interval row against the design aiming diagram.
Photometric Commissioning Test
Final AcceptanceMeasure beam intensity and colour with a calibrated photometer against ICAO/FAA commissioning tolerances for non-precision approach lighting.
Documentation & As-Built Sign-off
Final AcceptanceRecord insulation, continuity, voltage, and photometric readings alongside as-built light positions in the commissioning dossier for handover.
Inspection & Maintenance
Photometric Intensity Check
AnnualVerify beam intensity against ICAO / FAA thresholds using a calibrated photometer at representative points along the array; degraded output usually points to lens haze or an aging light source.
Lens Cleaning
QuarterlyClean environmental pollutants, bird droppings, and de-icing residue from every fixture, particularly the more distant lights and crossbars where visibility matters most.
Alignment & Crossbar Check
Semi-annualVerify fixture aim and crossbar positioning using a theodolite or laser alignment system, since wind, wildlife, or vehicle strikes can knock elevated fixtures out of tolerance.
Site Survey & Vegetation Clearance
Semi-annualWalk the approach line to confirm no vegetation or structures have grown up to obstruct the light output since the last inspection.
CCR & Power Quality Check
AnnualMonitor voltage stability and CCR step response across the array, since MALS systems draw significant power and are sensitive to fluctuations that cause inconsistent brightness.
Insulation Resistance Test
AnnualMegger-test isolation transformers and series circuits to confirm insulation resistance stays above the minimum, flagging moisture ingress before it causes a series-circuit fault.
Cable & Connector Inspection
AnnualExamine primary and secondary cable connections for corrosion or loose crimps, a common source of intermittent series-circuit faults across the array.
Frangible Coupling & Base Inspection
AnnualInspect elevated fixture couplings and base housings for corrosion or fatigue to ensure breakaway performance and structural stability along the full 427m (1,400 ft) run.
Common Field Issues
Lens Contamination
MALS components are exposed to environmental pollutants, bird droppings, and de‑icing chemicals. Regular cleaning with approved solvents and soft brushes is essential to maintain light output and visibility, especially for the distant lights and crossbars.
Misalignment of Elevated Fixtures
Elevated approach lights and crossbars can be knocked out of alignment by wind, wildlife, or maintenance vehicles. Regular alignment checks using a theodolite or laser alignment system are essential to maintain the correct beam direction and crossbar positioning.
Power Supply and CCR Issues
MALS systems draw significant power. Voltage fluctuations, CCR faults, or cable damage can cause inconsistent brightness or total failure. Regular power quality monitoring and cable testing are recommended.
Crossbar Light Failures
If crossbar lights are included, individual failures can disrupt the distance reference pattern. Regular inspection and replacement of faulty crossbar lights are essential to maintain the system's effectiveness.
Vegetation and Obstruction Growth
At smaller airfields, vegetation or structures can grow up around approach lights and crossbars, obstructing the light output. Regular site inspections and vegetation management are essential to maintain clear lines of sight.
Troubleshooting Guide
Single Light/Bar Dark, Rest of Array Normal
Entire Array Dark / CCR Will Not Regulate
Crossbar Light Failure / Distance Pattern Disrupted
CCR Trips on Overcurrent or Ground Fault
Elevated Fixture or Crossbar Misaligned
Reduced or Hazy Light Output
Failure Modes & Root Causes
Light Source (Lamp/LED) Failure
Isolating Transformer Winding Failure
L-823 Connector / Splice Degradation
Series Cable Insulation Breakdown
Elevated Fixture / Crossbar Frangible Coupling Fatigue
CCR Regulation Fault
Lens Contamination / Reduced Intensity
Crossbar Circuit Fault / Distance Pattern Disrupted
Safety & Operational Notes
Series Circuit Isolation
Electrical SafetyMALS bar and crossbar circuits run on a constant-current series loop that can carry several kV. De-energise and lock out the associated CCR, then verify zero energy at the tower base or bar before opening any enclosure.
Elevated Tower & Off-Runway Access
Personnel SafetyLight bar towers extend along the extended centreline over terrain that may be uneven or off the paved movement area; use fall protection when climbing frangible towers and assess ground conditions before positioning vehicles or ladders.
Frangibility Not to Be Defeated
MechanicalNever substitute a frangible coupling or tower base with a rigid fitting, and do not over-torque connections during installation or repair; the structure must still break away cleanly on aircraft impact within the runway safety area.
Airside Work Coordination
OperationalWork on approach lighting affects an active runway's usable minima; obtain ATC/airside coordination and issue a NOTAM before any bar or crossbar is taken out of service, and keep personnel and vehicles clear of the approach surface during aircraft operations.
Hot Lamp / Housing Contact
Personnel SafetyAllow the fixture housing and lamp/LED module to cool before handling after an active period; incandescent bar lamps in particular retain significant heat and can cause burns during lens or lamp replacement.
FOD Control Along the Approach
OperationalAccount for tools, fasteners, and hardware at every tower worked on, and remove or secure loose material before leaving the site, since debris in the approach area can be ingested or strike an aircraft on short final.
Insulation Test Before Re-Energisation
Electrical SafetyAfter any cable, connector, or transformer work on a bar or crossbar circuit, megger test the affected series loop before restoring power, since a residual fault can trip the CCR or damage healthy fixtures on the same circuit.
Restore to Compliant State
ComplianceDo not leave a bar out of aim tolerance or at reduced intensity; verify photometric and positional conformance before closing out the work and cancelling the associated NOTAM.
Engineering & Expert Notes
Crossbar Aim Errors Are Easy to Miss at a Glance
StructuralA crossbar can look correctly positioned from ground level while its individual light aim has drifted enough to weaken the lateral cue at typical approach range. Verify aim with survey instruments rather than visual inspection alone.
Don't Assume MALS Wiring Mirrors Precision System Practice
ElectricalBecause MALS lacks SFL control electronics, its loop topology is often simpler than a precision system and shouldn't be assumed to follow the same segmentation conventions when troubleshooting a fault or planning an upgrade — verify the as-built circuit directly.
Distant Lights Get Less Attention Than They Need
DurabilityThe lights furthest from the threshold are both the hardest to reach for maintenance and the most exposed to drainage runoff and wildlife activity; without a deliberate schedule weighting, they tend to accumulate contamination and misalignment faster than the near-threshold lights that get checked more often.
Track Intensity Trend Even Without an SFL Component
PhotometricIt's tempting to under-inspect a steady-burning-only system relative to a precision array, but MALS still provides the primary visual reference for the approaches it supports; trend intensity data on the same rigor as a more complex system.
A Single Dark Segment Can Look Like a CCR Fault When It's a Connector
TroubleshootingBecause MALS loops can run long distances with several intermediate connectors, a single degraded connector can present as a segment-wide dimming that looks like a CCR problem. Check connector condition along the affected segment before assuming the regulator has failed.
Document Crossbar Positions Before Any Runway Work Nearby
Upgrade PlanningIf pavement or drainage work is planned near the approach area, survey and record existing crossbar and centreline positions beforehand so post-work verification has a clear baseline to check against.
Frequently Asked Questions
Short answers about MALS (Medium Intensity Approach Lighting System): layout, length, standards, maintenance and common faults.
Q1What is MALS?
MALS (Medium Intensity Approach Lighting System) is an approach lighting system that gives pilots visual guidance during final approach. It uses seven five-light bars of steady-burning white lights along the extended runway centreline.
Q2How long is a MALS installation?
427 metres (1,400 ft) from the runway threshold, with the bars spaced at 61 m (200 ft) intervals.
Q3Does MALS have flashing lights or a crossbar?
No flashing lights, it is steady-burning only. The page describes an optional single crossbar of two five-light wing bars at 305 m (1,000 ft) from the threshold, which improves distance reference and depth perception.
Q4Where is MALS used?
On runways with higher traffic or more demanding weather, regional airports serving turboprop and regional jet operations, and military airfields where basic approach lighting is not enough.
Q5What light sources does MALS use?
LED arrays or halogen lamps of about 100 W to 200 W, white and steady-burning, on elevated frangible fixtures fed from the series circuit.
Q6Which standards apply to MALS?
The main references are ICAO Annex 14, FAA AC 150/5345-46 (light fixtures), IEC TS 61827 and FAA Engineering Brief 67 for LED components. Always verify the current edition and your aerodrome's approved requirements.
Q7How often should MALS be maintained?
Typically quarterly lens cleaning, semi-annual alignment and crossbar checks with a theodolite or laser system, and annual photometric intensity checks. Your airport's approved maintenance programme takes precedence.
Q8What are the common problems with MALS?
Lens contamination from pollutants, bird droppings and de-icing residue, misalignment of elevated fixtures, power supply and CCR issues, and individual crossbar light failures that upset the distance cue.
Related Components
Go Beyond the Component. Understand the Complete AGL System.
You have explored the component. Now understand how it works within the complete Airfield Ground Lighting system.
Learn AGL from fundamentals to design, installation, testing, photometry, commissioning, maintenance and troubleshooting through structured technical training at Precision AGL Academy.
Build practical knowledge. Understand the circuit. Read the standards. Troubleshoot with confidence.
Your next step in AGL starts here.
Need expert guidance on MALS selection, installation, or upgrade?
Precision AGL Academy provides advice on configuration, crossbar placement, intensity settings, and field testing of Medium Intensity Approach Lighting Systems.
Follow the Academy
Important Notice, Disclaimer & Limitation of Liability
Please read before relying on any content on this page.
- Purpose and intended users. This page on MALS is an independent educational and informational reference for competent, suitably trained and authorised airfield ground lighting (AGL) and aerodrome electrical personnel. It is not professional engineering, legal or regulatory advice, and using it does not create any professional or client relationship.
- Safety. Work on series circuits, constant current regulators (CCRs), isolating transformers, cables, connectors and lighting equipment can be fatal. Always apply the aerodrome’s permit-to-work and isolation/LOTO procedures, prove dead, use correctly rated instruments and PPE, and follow the manufacturer’s instructions. Nothing here authorises work on live equipment or the bypassing of any safety device or interlock.
- Aviation operations. Nothing here authorises installation, modification, energisation, adjustment, return to service, a change of operating category (CAT I/II/III), a NOTAM or any aerodrome certification or approval decision. These rest with the aerodrome operator, the air navigation service provider and the competent regulator.
- Specifications, ratings and typical values. Descriptions, parameters, ratings, dimensions, photometric values, wattages, service lives, maintenance tasks and intervals, failure modes, certifications (for example CE, FCC, UL or IEC marks) and part or type designations are general, typical and indicative. They may not match any particular product, make, model or version, and they are not a datasheet, design, specification, selection, sizing, procurement or acceptance criterion. The manufacturer’s current documents, the approved design and the project specification prevail.
- Standards and regulations. References to ICAO, FAA, IEC, IEEE, ISO, BIS, DGCA and other standards are paraphrased summaries for orientation only. They may be incomplete or out of date, and standards are revised from time to time. Consult the current official editions. Following this content does not guarantee compliance with any law, standard or regulatory approval, and the regulator’s requirements always prevail.
- No warranty. Content is provided “as is” and “as available”, without warranty of any kind, express or implied, including accuracy, completeness, currency or fitness for a particular purpose. Real installations differ in design, equipment make and model, age and condition.
- Limitation of liability. To the fullest extent permitted by applicable law, Precision AGL Academy, Precision AGL Solutions and their owners, authors and contributors are not liable for any injury, death, loss, damage, downtime, penalty or regulatory consequence, whether direct or indirect, arising from the use of, reliance on, or inability to use this content. Nothing in this notice excludes or limits any liability that cannot lawfully be excluded or limited.
- Independence, brands and no endorsement. This is an independent publication. It is not affiliated with, sponsored by or endorsed by ICAO, the FAA, the IEC, DGCA, AAI, any airport, regulator, supplier or equipment manufacturer. Third-party names, product designations, standard designations and trademarks (including Megger®, Siemens, Eaton, Crouse-Hinds, ADB SAFEGATE, Fluke, ABB and Honeywell) belong to their respective owners and are used only for identification and description. Mention of a brand, product or supplier is not a recommendation, and we do not sell, supply or quote for any component described.
- Images and third-party content. Images and illustrations are shown to help identify the type of component. They may show products of various manufacturers, may not depict the exact item described, and are not a statement about any product’s quality, approval or performance. Copyright and trademarks in third-party images, logos and photographs belong to their respective owners and are not claimed as ours. If you are a rights holder and want an image removed, replaced or credited, email precisionaglsolutions@gmail.com with the page address and we will act promptly.
- Training and services. Mentions of training, courses, consultation, advice, selection, installation, calibration or other support, including the “Learn…Certify” pathway, describe learning stages and are not an offer, quotation, tender or promise of any result. Contacting us or our replying creates no engagement or duty of care; an engagement exists only under a written agreement. We are not a regulator or certification body, and completing any course or reading this content is not a certification, accreditation or authorisation to work on any aerodrome.
- Copyright, privacy and corrections. © 2026 Precision AGL Academy. All rights reserved. Text, structure, compilations and diagrams may be viewed for personal reference and internal training only; any other copying, republication or commercial use needs our written permission. If you email, telephone or message us, we use your details only to respond and handle your matter, in line with applicable Indian law including the Digital Personal Data Protection Act, 2023; please do not send confidential or security-sensitive information. To display this page your browser requests fonts, icons and images from third-party servers, which receive your IP address and browser details under their own policies. Content is reviewed periodically with no obligation to update. To report an error, safety concern or rights issue, write to precisionaglsolutions@gmail.com.