AGL Component Library By Precision AGL Academy

Taxiway Intersection Light

A specialized taxiway guidance fixture installed at taxiway intersections to provide pilots with clear directional cues when navigating complex junction points. These lights use a combination of blue edge lights, green centreline lights, and sometimes yellow caution lights to define the intersection geometry and guide pilots through turns and crossing decisions.

Taxiway Intersection Light

Image disclaimer: For identification and illustration only. It may show a product by another manufacturer and may not depict the exact item described; it is not a statement of any product’s quality, approval or performance. Third-party image and trademark rights belong to their owners. See full notice.

Overview

What Is It?

A Taxiway Intersection Light is a specialized taxiway guidance fixture installed at taxiway intersections to provide pilots with clear directional cues when navigating complex junction points. These lights use a combination of blue edge lights, green centreline lights, and sometimes yellow caution lights to define the intersection geometry and guide pilots through turns and crossing decisions. Intersection lights are critical for preventing wrong-turn errors, runway incursions, and ground collisions at busy airfields where multiple taxiways converge. They help pilots maintain situational awareness and make correct routing decisions during ground movement.

Purpose

Purpose & Function

Taxiway intersections concentrate exactly the kind of decision-making risk simple edge and centreline lighting elsewhere on the taxiway doesn't have to handle: multiple possible paths converging in one place, where a wrong turn or a misjudged crossing can put an aircraft into conflict with another that has right of way. The intersection light's purpose is to make the geometry of that junction visually unambiguous, so a pilot can see at a glance which path leads where before committing to a turn.

Layering blue edge, green centreline, and yellow caution lighting together at these points gives pilots the same trusted colour vocabulary they use everywhere else on the airfield, but concentrated and combined precisely where the risk of a wrong-turn error or ground conflict is highest, which is what makes intersection-specific lighting a meaningful safety addition beyond standard taxiway guidance alone.

Application

Where Is It Used?

Taxiway intersection lights are installed at all types of taxiway junctions and complex ground movement areas. They are used on:

  • Complex taxiway intersections where multiple taxiways converge
  • Apron entry/exit points where aircraft transition between apron and taxiway
  • Runway holding position intersections where taxiways meet the runway
  • Angled intersections requiring clear directional cues
  • Low visibility operations where enhanced guidance is essential
  • Military airfields with complex taxiway layouts
Placement

Installation & Location

Fixtures are set out at the specific geometry of the intersection they serve, with blue edge, green centreline, and yellow caution lights positioned according to the actual paths and turn radii available at that junction rather than a generic straight-taxiway spacing. Mounting is typically inset to match the surrounding standard taxiway lighting, with fixture positions tied to the same survey used to lay out the intersection's pavement markings so the lit geometry and the painted geometry agree. Because intersections often see lighting elements from more than one taxiway segment converging in a small area, cable runs and circuit assignments are planned so each segment's lighting remains on its own circuit through the intersection, preserving the ability to isolate one taxiway's lighting for maintenance without affecting an intersecting one. Sightlines from each approach direction into the intersection are checked during installation to confirm no fixture is shadowed by another light, a sign, or pavement furniture from the angle a pilot will actually be approaching from.

Function

How Does It Work?

Taxiway intersection lights operate using a coordinated lighting strategy:

  • Edge Lighting: Blue edge lights are installed along the edges of all taxiways entering the intersection, maintaining the standard taxiway edge definition.
  • Centreline Guidance: Green centreline lights are installed through the intersection along the primary taxiway routes, providing continuous guidance.
  • Caution Indication: Yellow or amber lights may be used at the intersection to alert pilots to the presence of a junction and the need for caution.
  • Directional Cues: At complex intersections, lights may be configured to provide directional guidance, using either flashing or steady patterns to indicate the preferred route.
  • Integration: The system is integrated with other taxiway guidance systems (edge lights, centreline lights, holding position lights) and the overall AGL control system.
Architecture

System Architecture & Control Logic

An intersection is a meeting point of circuits, not a single controlled object — the blue edge lights, green centreline lights, and any yellow/amber caution or directional lights present are each part of their own series loop and their own CCR, and each is controlled and fault-reported independently even though they physically converge in the same few metres of pavement. The ALCMS coordinates the picture a pilot actually sees by managing these circuits together rather than by controlling the intersection as a unit: it can, for instance, keep edge and centreline lighting continuously energised while switching a directional or caution indication on and off for a specific routing. At complex or high-traffic intersections this coordination increasingly moves into A-SMGCS route-sequencing logic, which can command specific centreline segments through the junction to create a "follow-the-greens" path for a particular aircraft — a capability that depends on the centreline circuit through the intersection being individually switchable rather than one continuous loop. Because each colour's circuit is independent, a fault on the caution lighting at an intersection has no effect on the edge or centreline guidance running through the same point.

Diagram

Three Colours Defining One Junction

Plan view: four taxiways converging at one intersection green — through-route guidance blue — all taxiway edges yellow — junction ahead

Unlike the single-turn geometry of a runway exit, an intersection light has to define a junction where several paths meet: blue edge lights run continuously along every taxiway approaching the intersection, green centreline lights carry each through-route across the junction without a break, and a yellow caution marker sits at the point of convergence itself — giving the pilot both "which lane" and "junction ahead" information in the same glance.

Construction

Physical Construction

An intersection installation is a coordinated set of individually built fixtures rather than one combined unit: blue edge fixtures (LED or filtered 15W–45W halogen), green centreline fixtures (LED or filtered 45W–65W halogen), and where fitted, yellow/amber caution fixtures (LED or filtered 15W–45W halogen), each in its own die-cast aluminium body, gasket-sealed at the prism and rated IP67/IP68. Edge lights are typically elevated on frangible couplings seated in L-867 base cans around the intersection perimeter, while centreline and caution fixtures are flush-mounted in L-868 base cans through the pavement itself, load-rated for a 100,000 kg (220,000 lb) aircraft wheel. What makes the installation function as a single "intersection light" component is the coordinated wiring plan: each colour group runs back through its own isolating transformer (15W–65W depending on colour) to keep circuits separable for fault-finding, while the physical layout of edge, centreline, and caution fixtures is fixed by the intersection's geometry so the resulting light pattern reads unambiguously to an approaching pilot.

Specification

Technical Parameters

ParameterTypical Value
Light Source (Edge)Blue LED array or 15W – 45W halogen with blue filter
Light Source (Centreline)Green LED array or 45W – 65W halogen with green filter
Light Source (Caution)Yellow/Amber LED array or 15W – 45W halogen with yellow filter
Edge Light ColourBlue (standard taxiway edge)
Centreline ColourGreen (steady)
Caution ColourYellow/Amber (flashing or steady)
Luminous Intensity (Edge)100 – 1,000 candela
Luminous Intensity (Centreline)200 – 2,000 candela
Intensity Control3 to 5-step CCR controlled (2.8A – 6.6A)
ConfigurationEdge lights along all taxiway edges + centreline lights through intersection
Mounting TypeElevated (frangible) or Inset (flush)
Load Capacity (inset)100,000 kg (220,000 lbs) wheel load
Isolating Transformer15W – 65W (6.6A series circuit)
Protection ClassIP67 / IP68 (submersible)
Operating Temperature-40°C to +55°C
Power Supply

Electrical Requirements

RequirementTypical Value
Circuit TypeSeries circuit, constant current (CCR fed)
Rated Series Current6.6A (5-step: 2.8A / 3.4A / 4.1A / 5.2A / 6.6A)
IsolationVia dedicated isolating transformer (15W–65W, per light source) per unit
Multi-Source WiringEdge, centreline, and caution light sources within the fixture may be fed from separate series circuits so each function can be switched independently
Transformer SecondaryMatched to fixture wattage; sized to series circuit rating
Cable TypeL-824 single-conductor, direct-burial rated, 5kV or 600V per circuit design
ConnectorL-823 primary connector, submersible-rated splice
Insulation Resistance≥ 50 MΩ (megger test, cable-to-ground)
Earthing/GroundingFixture body and base can bonded to airfield earth grid
Fault ProtectionCCR-level ground fault and open-circuit detection
Power SourceCCR output, regulated per ICAO/FAA intensity step schedule
Optical Performance

Photometric Requirements

ParameterTypical Value
Edge Element Intensity100 – 1,000 cd (blue), where an edge light source is included
Centreline Element Intensity100 – 1,000 cd (green), where a centreline light source is included
Caution Element Intensity100 – 1,000 cd (yellow), where a caution light source is included
Independent SwitchingEach colour element switched independently to mark the intersection geometry correctly for the active taxi route
Vertical Beam SpreadMain beam 2°–10° above horizontal (peak ~3°–4°)
Horizontal Beam SpreadOmnidirectional (360°) or directional per element, depending on intersection geometry
Isocandela DistributionPer ICAO Annex 14 Attachment A / FAA AC 150/5345-46 intersection light figures
ChromaticityBlue, green, and yellow elements within ICAO Annex 14 colour boundaries
Test MethodMobile photometric van/goniophotometer per light source within the fixture
Compliance

Applicable Standards

ICAO Annex 14

Taxiway intersection lighting requirements and configuration standards

FAA AC 150/5345-46

Specification for Runway, Taxiway, Heliport, and Vertiport Light Fixtures — covers this fixture's general photometric and electrical requirements

IEC 61822

Constant current regulators and monitoring device for the series circuit(s) feeding this fixture

IEC 61821

Maintenance requirements for the AGL constant-current series circuits supplying this fixture

Prerequisites

Installation Requirements

Base Can Excavation & Grade
Civil

Excavate and set inset base cans to match the surrounding standard taxiway lighting, holding each flush with the pavement.

Marking-Survey Set-out
Civil

Set out blue edge, green centreline, and yellow caution light positions from the same survey used to lay out the intersection's pavement markings, following the actual paths and turn radii available rather than generic straight-taxiway spacing.

Multi-Approach Sightline Check
Mechanical

Check sightlines from each approach direction into the intersection, confirming no fixture is shadowed by another light, a sign, or pavement furniture from a pilot's actual approach angle.

Per-Segment Circuit Planning
Electrical

Plan cable runs and circuit assignments so each converging taxiway segment's lighting remains on its own circuit through the intersection, preserving the ability to isolate one segment for maintenance.

L-823 Connector Termination
Electrical

Terminate and seal the primary connector at each fixture per manufacturer procedure, keeping every splice submersible-rated before backfill.

Isolating Transformer Matching
Electrical

Confirm each isolating transformer's wattage matches its fixture and its segment circuit's rated current step before connection.

Load-Rated Housing Seating
Mechanical

Seat each fixture housing fully home in its base can and confirm it sits flush and level.

Pre-Energisation Sign-off
Documentation

Record base can positions, per-segment circuit assignment, and sightline check results as-built before backfill.

Verification

Testing & Commissioning

Insulation Resistance (Megger) Test
Pre-Energisation

Megger-test each colour group's isolating transformer and series loop before the circuit is energised, confirming insulation resistance clears the acceptable minimum ahead of backfill.

Loop Continuity & Resistance Test
Pre-Energisation

Verify series loop continuity for each colour group end to end and record total loop resistance, ruling out open circuits or high-resistance splices before first energisation.

Primary/Secondary Voltage Verification
Energisation

With the CCR energised, confirm secondary voltage at each L-823 connector matches the transformer's rated ratio at the commissioned current step.

CCR Brightness Step Response
Energisation

Cycle each colour group's CCR through every intensity step and confirm the corresponding fixtures respond correctly, ruling out marginal transformers or loose connections.

Colour-Coded Circuit Verification
Final Acceptance

Confirm blue edge, green centreline, and (where fitted) yellow caution fixtures each show the correct colour from their intended viewing direction, matching the intersection layout diagram.

Photometric Commissioning Test
Final Acceptance

Measure beam intensity and colour for each fixture group with a calibrated photometer against ICAO/FAA commissioning tolerances prior to operational handover.

Frangibility / Base Can Verification
Pre-Energisation

Confirm the frangible coupling on elevated edge fixtures and base can depth on flush-mounted centreline/caution fixtures meet as-built tolerances before the site is finally backfilled.

Documentation & As-Built Sign-off
Final Acceptance

Record insulation, continuity, voltage, and photometric readings for each colour group alongside as-built position in the commissioning dossier for handover.

Upkeep

Inspection & Maintenance

Configuration Documentation Audit
Annual

Review circuit and fixture-type documentation for the intersection to keep maintenance and troubleshooting accurate as configurations get complex.

Lens Cleaning
Quarterly

Clean all fixture types at the intersection of rubber deposits, dust, and de-icing fluid residue to maintain light output and colour fidelity.

Colour Filter & Photometric Check
Annual

Test blue, green, and yellow filters for colour shift or reduced output and replace as needed.

Circuit & Connector Inspection
Annual

Check wiring and connectors across the multiple circuits present at the intersection for corrosion or loose connections.

Housing & Seal Inspection
Annual

Check fixture housings and seals for moisture ingress across all light types at the intersection.

Field Notes

Common Field Issues

Complex Configuration Management

Intersection lighting configurations can be complex, with multiple circuits and light types. Proper documentation and labelling are essential to ensure correct maintenance and troubleshooting. Mismatched configurations can lead to pilot confusion.

Lens Contamination

All intersection lights are exposed to rubber deposits, dust, and de-icing fluids. Regular cleaning with approved solvents and soft brushes is required to maintain light output and colour fidelity across all fixture types.

Colour Filter Degradation

Blue, green, and yellow filters are all susceptible to UV degradation and thermal stress. Over time, colour shift or reduced output can occur. Regular photometric testing and filter replacement is essential.

Field Notes

Troubleshooting Guide

Wrong Colour or Fixture Type Reported at an Intersection
Likely Cause
Configuration mismatch between the installed fixture and the intersection's documented lighting plan, often after a repair using the wrong replacement unit.
Diagnostic Steps
Compare the installed fixture colour/type against the current intersection lighting configuration drawing.
Corrective Action
Replace with the correct fixture type per the configuration drawing, and update documentation and labelling to prevent recurrence.
Reduced Light Output or Colour Fidelity
Likely Cause
Lens contamination from rubber deposits, dust, and de-icing fluids across multiple fixture types at the intersection.
Diagnostic Steps
Take photometric readings across the affected fixtures and compare to rated output; visually inspect lenses for contamination.
Corrective Action
Clean lenses with approved solvents and soft brushes across all affected fixtures, and re-check output.
Colour Filter Fade Across Blue, Green, or Yellow Fixtures
Likely Cause
UV and thermal degradation of colour filters, which can progress at different rates across the mixed fixture types at an intersection.
Diagnostic Steps
Run photometric colour checks on each fixture type at the intersection and compare against their respective chromaticity specs.
Corrective Action
Replace faded filters on the affected fixtures and re-verify colour compliance.
Isolated Fixture Dark Within a Complex Circuit
Likely Cause
An open-circuit fault at one fixture within a multi-circuit intersection layout, made harder to trace by the number of circuits present.
Diagnostic Steps
Cross-reference the intersection's circuit documentation to identify which loop feeds the dark fixture; megger that loop to isolate the fault.
Corrective Action
Repair or replace the faulted component, then verify the fix against the documented configuration to avoid re-introducing confusion.
Reliability

Failure Modes & Root Causes

Fixture Type / Configuration Mismatch
Medium Severity
Root Cause
A repair using the wrong replacement unit, creating a mismatch with the documented lighting plan.
Effect
The wrong colour or fixture type is displayed at the intersection, risking pilot confusion.
Detection Method
Comparison of the installed fixture colour/type against the current intersection lighting configuration drawing.
Lens Contamination Across Fixture Types
Low Severity
Root Cause
Rubber deposits, dust, and de-icing fluids accumulating across the mixed fixture types at the intersection.
Effect
Reduced light output and colour fidelity across the affected fixtures.
Detection Method
Photometric readings across affected fixtures compared to rated output, alongside visual lens inspection.
Colour Filter Degradation
Medium Severity
Root Cause
UV and thermal stress on blue, green, or yellow filters, progressing at different rates across mixed fixture types.
Effect
Colour shift or reduced output on the affected fixtures.
Detection Method
Photometric colour checks on each fixture type compared against their respective chromaticity specs.
Isolated Fixture Open Circuit
Medium Severity
Root Cause
An open-circuit fault at one fixture within the intersection's multi-circuit layout.
Effect
A single fixture goes dark, made harder to trace by the number of circuits present.
Detection Method
Cross-reference of circuit documentation to identify the feeding loop, followed by a megger test to isolate the fault.
Precautions

Safety & Operational Notes

Isolate All Circuits Feeding the Intersection
Electrical Safety

Intersection lights typically combine blue edge, green centreline, and sometimes yellow elements on separate circuits; de-energise and lock out every CCR involved and verify zero energy before opening any base can.

Colour/Circuit Verification Before Restoration
Compliance

Confirm each lens colour is reconnected to its correct circuit and position before re-energising; a swapped blue/green/yellow element at a junction can mislead a pilot's routing decision and contribute to a runway incursion.

Airside Work Coordination
Operational

Complex junction points see converging traffic from multiple taxiways; coordinate with ATC/ground control, raise a NOTAM for any degraded guidance, and keep personnel clear of the through paths.

FOD Control at the Base Can
Operational

Keep tools, fasteners, and gaskets accounted for while any base can at the intersection is open, and secure or remove loose material before reinstating the fixtures.

Insulation Test Before Re-Energisation
Electrical Safety

Megger test each affected circuit after any cable, connector, or transformer work before restoring power, since a residual fault can take down the whole junction's guidance pattern.

PPE & Grounding
Personnel Safety

Use insulated tools and appropriate PPE on series-circuit connections, and confirm bonding/grounding of each base can before reconnecting.

Restore to Compliant State
Compliance

Verify full intersection geometry reads correctly to a pilot from all approach legs before closing out the work and cancelling the NOTAM.

Field Insight

Engineering & Expert Notes

Colour/Circuit Mapping Belongs in the As-Built, Not Memory
Compliance

Complex junctions combining blue edge, green centreline, and yellow elements are exactly where "the technician remembers how it goes together" fails during a callout at short notice; keep an accurate as-built wiring diagram at the junction, since guessing a colour-to-circuit mapping under time pressure is how incursion-risk swaps happen.

Geometry Reads Differently From Each Approach Leg
Design

A junction that looks correct when checked while standing on one taxiway can present a confusing or contradictory picture from a different approach leg; walk and view the intersection from every leg used in service, not just the one nearest the work area.

Trend Loop Readings, Don't Just Spot-Check
Troubleshooting

Moisture ingress at an L-823 connector usually shows up first as a slow drift in loop insulation resistance, not a hard fault. Logging megger readings over successive maintenance cycles catches a failing splice months before it takes the loop down.

Balance Loops Sharing One CCR
Design

Where multiple series loops run off a single CCR, unequal loop lengths or lamp counts between loops can produce visibly uneven brightness even though each individual fixture tests within photometric tolerance. Balance loop impedance at the design stage, not after commissioning complaints.

Size the Transformer to the Load, Not the Legacy Lamp
Electrical

Reusing an isolating transformer sized for the old incandescent wattage on a much lower-draw LED fixture is a common source of premature transformer failure and nuisance loop trips; re-select VA rating against the actual LED load rather than assuming the existing transformer is "close enough."

De-Icing Fluid Ages Seals Faster Than UV Alone
Durability

Repeated exposure to glycol-based de-icing fluid degrades gaskets and lens seals faster than sun and weather alone at a junction that sees concentrated de-icing traffic from multiple directions. Specify seal materials rated for glycol contact and inspect gasket condition at overhaul, not only at initial install.

Quick Answers

Frequently Asked Questions

Short answers about taxiway intersection lights: colour combinations, switching, standards and maintenance.

Q1What is a taxiway intersection light?

It is a taxiway guidance fixture arrangement installed at junctions to give pilots clear directional cues where several taxiways converge. It combines blue edge, green centreline and yellow caution lighting.

Q2What colours are used at taxiway intersections?

Blue for the taxiway edges, green for centreline guidance through the intersection and yellow or amber for caution, flashing or steady, to alert pilots to the junction.

Q3Why are intersection lights configured differently from normal taxiway lights?

Intersections concentrate decision-making risk, with multiple possible paths in one place. Layering the familiar colour code exactly where the geometry gets complex reduces the chance of a wrong turn.

Q4Can each colour at an intersection be switched separately?

Yes. Each colour element can be switched independently so the intersection geometry is marked correctly for the active taxi route.

Q5Where are taxiway intersection lights installed?

At complex taxiway junctions, apron entry and exit points, runway holding position intersections and angled intersections, and in low-visibility operations.

Q6Which standards apply to taxiway intersection lights?

The main references are ICAO Annex 14 and FAA AC 150/5345-46, with IEC 61822 for the constant current regulators and IEC 61821 for maintenance of the series circuits. Always verify the current edition.

Q7How often should taxiway intersection lights be maintained?

Typical intervals are an annual configuration documentation audit, quarterly lens cleaning, and annual colour filter and photometric checks and circuit and connector inspection.

Q8What should I do if the wrong colour or fixture type appears at an intersection?

Compare the installed fixture against the current intersection lighting configuration drawing. It is often a repair with the wrong replacement unit, so replace it with the correct type and update the documentation and labelling.

Go Further

Go Beyond the Component. Understand the Complete AGL System.

You have explored the component. Now understand how it works within the complete Airfield Ground Lighting system.

Learn AGL from fundamentals to design, installation, testing, photometry, commissioning, maintenance and troubleshooting through structured technical training at Precision AGL Academy.

Build practical knowledge. Understand the circuit. Read the standards. Troubleshoot with confidence.

Your next step in AGL starts here.

The Learning Pathway
Learn Understand Design Test Maintain Document Apply Certify

Need expert guidance on taxiway intersection light configuration or installation?

Precision AGL Academy provides advice on intersection geometry, lighting configuration, and field testing of taxiway intersection lighting systems.