Unidirectional Runway Centreline Light
A flush‑mounted runway centreline light that projects light in a single direction along the runway axis. Designed for runways with a predominant approach direction or where bidirectional guidance is not required, it provides cost‑effective longitudinal reference with the standard white‑red‑white colour coding to indicate remaining runway distance.
Image disclaimer: For identification and illustration only. It may show a product by another manufacturer and may not depict the exact item described; it is not a statement of any product’s quality, approval or performance. Third-party image and trademark rights belong to their owners. See full notice.
What Is It?
A Unidirectional Runway Centreline Light is an inset fixture that emits light in only one direction along the runway centreline. It is typically oriented towards the approaching aircraft, providing a clear visual reference for the runway centreline during take‑off and landing. The colour coding follows the standard ICAO/FAA convention: white from the threshold to 900 m from the runway end, alternating red and white between 900 m and 300 m, and red in the last 300 m. This unidirectional design reduces cost and complexity compared to bidirectional versions, making it suitable for runways where operations are predominantly in one direction or for non‑precision approaches where bidirectional guidance is not mandated.
Purpose & Function
The unidirectional centreline light's purpose is to keep an aircraft tracking precisely down the centre of the runway during the roll or takeoff, in situations where operations predominantly happen in one direction and the added cost of full bidirectional visibility isn't justified. Aiming the beam specifically toward the approaching or departing aircraft concentrates intensity where it's actually needed, rather than splitting light output in a direction that won't be used.
The colour transitions along its length — white, then alternating red and white, then solid red — exist to give the pilot a continuous, built-in sense of remaining runway distance without needing to consult an instrument, which becomes essential in low visibility landing rolls where visually judging distance to the runway end by eye alone is unreliable.
Where Is It Used?
Unidirectional centreline lights are installed on runways where the primary approach and take‑off direction is fixed, such as at airports with prevailing wind patterns or where terrain constraints dictate a single operational direction. They are common on non‑precision runways (e.g., VFR or CAT I) where the lower cost of unidirectional fixtures is acceptable. They are also used as supplementary guidance on the departure end of bidirectional runways where only approach guidance is required from one side. The lights are spaced at 15‑metre intervals for CAT I runways and can be used on CAT II/III runways if bidirectional is not required, though typically high‑intensity bidirectional fixtures are preferred for low‑visibility operations.
Installation & Location
Fixtures are recessed into the runway pavement along the centreline at 15 m intervals (CAT I) using a load-rated inset base can, with the fixture's single-direction optical assembly oriented squarely to face the predominant approach/landing direction the runway serves. Because the fixture emits no useful beam in the reverse direction, setting-out and orientation checks are more important here than for bidirectional fixtures — a rotated or misaligned base can produces a centreline light invisible from the intended approach even though the fixture itself is functioning correctly. Cabling and isolating transformer arrangements follow the standard runway centreline convention, with position tied to the runway centreline survey for the served approach direction.
How Does It Work?
Each unidirectional centreline light is powered from the constant current series circuit via an isolating transformer. The fixture contains a single optical system (reflector, prism, and lens) that projects a narrow beam (typically 4° vertical × 6° horizontal) in one direction along the runway centreline. This beam is carefully aligned with the runway axis to ensure it is visible to pilots on approach over a long distance. The colour is determined by a dichroic filter or coloured lens that corresponds to the fixture's position along the runway. The intensity is controlled by the CCR's current steps, with higher intensities (up to 6.6 A) used during low‑visibility operations. Because the light only emits in one direction, it is not visible to pilots approaching from the opposite end, which is acceptable for runways with a defined operational direction.
System Architecture & Control Logic
Unidirectional centreline lights are not individually addressable — control is exercised at the loop level through the constant current series circuit serving the runway centreline. An ALCMS, driven by tower instruction or an automated visibility-linked routine, selects the required brightness step, and the CCR regulates the entire loop to a single fixed current (up to 6.6A for the lowest RVR conditions the runway supports). Every fixture on the loop, via its own isolating transformer, draws the same current and burns at the same intensity simultaneously — the electrical control is identical to a bidirectional centreline circuit, since the current step has no bearing on which way the fixture's single optical assembly is aimed. What is unique to this fixture is that orientation, not electrical control, determines visibility: because the beam only reaches pilots approaching from the served direction, correct alignment at installation is what makes the loop-level current command meaningful for traffic in that direction, and there is no CCR command that can compensate for a fixture facing the wrong way. Fault detection remains loop-based: the CCR monitors loop voltage against commanded current, and a voltage rise — typically an open-circuit source or failed isolating transformer — is reported to the ALCMS as a loop fault, isolated to a specific fixture only through sectionalised field testing.
Electrically, this fixture behaves exactly like a bidirectional centreline light on the same loop. The one-way visibility is purely an optics-and-installation property, invisible to the CCR and the ALCMS.
Circuit & Beam Overview
The colour transition (white → red/white → red) is the same convention used on bidirectional centreline lighting — the difference here is that each fixture only projects its colour one way, so the full white‑to‑red picture is only visible to traffic moving in the runway's intended direction.
Physical Construction
The fixture uses a die-cast aluminium body, machined and anodised or powder-coated for corrosion resistance, set flush into an L-852-series base can recessed into the runway pavement. A single lamp or LED array and prism assembly is aimed along the runway axis toward the approach direction, with coloured filter segments or dual-colour LED elements built into the optical path to produce the white, alternating red/white, or red output required at different points along the runway. The optical elements sit beneath a toughened glass or polycarbonate top lens, load-rated for aircraft wheel loading and gasket-sealed with an O-ring to achieve an IP67/IP68 rating. Internal wiring terminates at a sealed L-823 primary connector mating to the secondary lead of a nearby isolating transformer housed in its own base can, with stainless-steel fasteners and a drainage channel in the base can preventing standing water around the connector and transformer.
Technical Parameters
| Parameter | Typical Value |
|---|---|
| Light Source | LED array or 45W / 65W halogen |
| Colour Coding | White (threshold to 900m before runway end), Alternating Red/White (900m–300m before runway end), Red (last 300m before runway end) |
| Intensity (Max) | Up to 10,000 cd (LED) / 8,000 cd (halogen) at 6.6A |
| Intensity Steps | 5‑step (2.8A – 6.6A) CCR controlled |
| Spacing | 15m / 50ft, uniform for all categories where fitted (CAT I/II/III) |
| Beam Pattern | Unidirectional (4° vertical x 6° horizontal) |
| Mounting Type | Flush‑mounted (inset) in pavement |
| Load Capacity | 100,000 kg (220,000 lbs) wheel load |
| Isolating Transformer | 45W / 65W (6.6A series circuit) |
| Protection Class | IP67 / IP68 (submersible, pressure‑vented) |
Electrical Requirements
| Requirement | Typical Value |
|---|---|
| Circuit Type | Series circuit, constant current (CCR fed) |
| Rated Series Current | 6.6A (5-step: 2.8A / 3.4A / 4.1A / 5.2A / 6.6A) |
| Isolation | Via dedicated isolating transformer (45W/65W) per unit |
| Transformer Secondary | Matched to fixture wattage; sized to series circuit rating |
| Cable Type | L-824 single-conductor, direct-burial rated, 5kV or 600V per circuit design |
| Connector | L-823 primary connector, submersible-rated splice |
| Insulation Resistance | ≥ 50 MΩ (megger test, cable-to-ground) |
| Earthing/Grounding | Fixture body and base can bonded to airfield earth grid |
| Fault Protection | CCR-level ground fault and open-circuit detection |
| Power Source | CCR output, regulated per ICAO/FAA intensity step schedule |
Photometric Requirements
| Parameter | Typical Value |
|---|---|
| Main Beam Intensity | Up to 10,000 cd (LED) / 8,000 cd (halogen) at 6.6A (white/red per zone), unidirectional toward the approach direction |
| Colour Zoning | White from threshold to 900 m before the runway end, alternating red/white from 900 m to 300 m before the end, red for the final 300 m |
| Intensity Steps | 100% / 30% / 10% / 3% / 1% of rated peak intensity |
| Vertical Beam Spread | Main beam 1°–15° above horizontal, unidirectional (rear cut-off toward departing traffic) |
| Horizontal Beam Spread | ± 5° either side of runway centreline |
| Isocandela Distribution | Per ICAO Annex 14 Attachment A / FAA AC 150/5345-46 unidirectional centreline figures |
| Chromaticity | White and red within ICAO Annex 14 colour boundaries |
| Maintenance Factor | ≥ 50% of new-fixture intensity before replacement/cleaning is due |
| Test Method | Mobile photometric van/goniophotometer or fixed test bench per fixture |
Applicable Standards
ICAO Annex 14
Centreline light colour, spacing, and photometric requirements for unidirectional fixtures
FAA AC 150/5345-46
Specification for Runway, Taxiway, Heliport, and Vertiport Light Fixtures — covers this fixture's general photometric and electrical requirements
IEC/TS 61827
Characteristics of inset and elevated luminaires used on aerodromes and heliports (photometric & electrical performance)
FAA Engineering Brief #67
Light Sources Other than Incandescent and Xenon for Airport and Obstruction Lighting Fixtures
Installation Requirements
Base Can Recess & Grade
CivilRecess the load-rated inset base can into the runway pavement, holding it flush with the surface at the design 15 m (CAT I) interval along the centreline.
Orientation to Approach Direction
MechanicalOrient the fixture's single-direction optical assembly squarely to face the predominant approach/landing direction the runway serves, checking orientation carefully since the fixture emits no useful beam in reverse and a rotated base can produces a light invisible from the intended approach even when functioning correctly.
Duct & Cable Route
ElectricalRun the series circuit duct beneath the pavement following the standard runway centreline convention.
L-823 Connector Termination
ElectricalTerminate and seal the primary connector per manufacturer procedure, keeping the splice submersible-rated before the base can is closed.
Isolating Transformer Matching
ElectricalConfirm the isolating transformer wattage matches the fixture and the series circuit's rated current step before connection.
Load-Rated Housing Seating
MechanicalSeat the fixture housing fully home in the base can and confirm it sits flush and level to carry full aircraft wheel load.
Approach-Direction Orientation Check
DocumentationVerify and record each fixture's facing direction against the served approach before backfill, since orientation errors are not visible after the pocket is closed.
Pre-Sealing Sign-off
DocumentationRecord base can position, cable route, connector seal, and orientation as-built before the pocket is finally sealed.
Testing & Commissioning
Insulation Resistance (Megger) Test
Pre-EnergisationMegger-test the isolating transformer and series loop before the circuit is energised, confirming insulation resistance clears the acceptable minimum ahead of backfill.
Loop Continuity & Resistance Test
Pre-EnergisationVerify series loop continuity end to end and record total loop resistance, ruling out open circuits or high-resistance splices before first energisation.
Primary/Secondary Voltage Verification
EnergisationWith the CCR energised, confirm secondary voltage at the L-823 connector matches the transformer's rated ratio at the commissioned current step.
CCR Brightness Step Response
EnergisationCycle the CCR through every intensity step and confirm the fixture responds correctly at each, ruling out marginal transformers or loose connections.
Colour Zone & Direction Verification
Final AcceptanceConfirm the fixture shows the correct colour for its zone — white, alternating red/white, or red — and that the beam is oriented towards the approaching aircraft as specified.
Photometric Commissioning Test
Final AcceptanceMeasure beam intensity, colour, and beam spread with a calibrated photometer against ICAO/FAA commissioning tolerances prior to operational handover.
Base Can & Drainage Verification
Pre-EnergisationConfirm base can depth, drainage channel, and pavement seal meet as-built tolerances before the surrounding surface is finally reinstated.
Documentation & As-Built Sign-off
Final AcceptanceRecord insulation, continuity, voltage, and photometric readings alongside as-built position in the commissioning dossier for handover.
Inspection & Maintenance
Beam Alignment Check
Semi-annualConfirm beam alignment with the runway axis, since a unidirectional beam is unforgiving of drift.
Colour Filter Inspection
Semi-annualCheck the colour filter for fading, which concentrates on the exposed face under unidirectional UV exposure.
Lens Cleaning
MonthlyClean the lens of rubber deposits laid down by aircraft tyres before build-up alters beam output.
Seal & Gasket Inspection
AnnualCheck seals and gaskets for degradation that could let moisture into the fixture.
Common Field Issues
Beam Misalignment with Runway Axis
Because the light is unidirectional, any misalignment during installation or after pavement settlement results in the beam being directed off‑axis, reducing visibility for pilots. Regular alignment checks using a precision alignment jig and digital level are essential to maintain the beam within ±0.5° of the runway centreline.
Inadequate Visibility from the Opposite Direction
Unidirectional lights are not visible from the opposite end, which can be a safety concern if the runway is used in both directions unexpectedly (e.g., during wind shifts). Airports should ensure that operational procedures and signage clearly indicate the active direction, and consider installing bidirectional fixtures if reverse operations are common.
Colour Filter Degradation from Unidirectional UV Exposure
The single optical path is subject to constant UV and thermal stress, which can cause the red and white filters to fade or shift over time. Regular photometric testing and filter replacement are required to maintain the colour‑distance coding integrity.
Lens Contamination from Rubber Deposits
Like all centreline lights, unidirectional fixtures are prone to rubber deposit accumulation from aircraft tyres, especially in the touchdown zone. Regular cleaning with approved solvents and soft brushes is necessary to maintain light output and beam quality.
Troubleshooting Guide
Single Fixture Dark, Rest of Circuit Normal
Entire Series Circuit Dark / CCR Will Not Regulate
CCR Trips on Overcurrent or Ground Fault
Beam Off the Runway Centreline Axis
Colour-Distance Coding Appears Faded or Shifted
Reduced Light Output from Rubber Deposits
Failure Modes & Root Causes
Isolating Transformer / LED Module Failure
Series Loop Open Circuit
Beam Misalignment with Runway Axis
Colour-Distance Coding Filter Degradation
Lens Contamination from Rubber Deposits
Safety & Operational Notes
Series Circuit Isolation
Electrical SafetyDe-energise and lock out the CCR feeding the centreline circuit and verify zero energy at the fixture before opening the inset base can or disturbing connectors.
Verify Approach-Direction Orientation
ComplianceConfirm the unidirectional optic faces the correct approach direction before reinstating the fixture; installing it reversed defeats its purpose and can leave the pilot without the expected centreline cue.
Correct Colour-Zone Lamp Installation
ComplianceMatch the replacement lamp or LED module to the fixture's zone (white, alternating red/white, or all-red) before closing up, since an incorrect colour misrepresents remaining runway length.
Airside Work Coordination
OperationalCoordinate with ATC/airside and raise a NOTAM where the fixture will be dark or out of tolerance, and keep personnel and vehicles clear of the runway strip.
FOD Control at the Base Can
OperationalKeep tools, fasteners, and gaskets accounted for while the base can is open, and secure or remove loose material before reinstating the fixture.
Insulation Test Before Re-Energisation
Electrical SafetyMegger test the affected series loop before restoring power, since a residual fault at re-energisation can trip the CCR or damage other fixtures on the same circuit.
PPE & Grounding
Personnel SafetyUse insulated tools and appropriate PPE on series-circuit connections, and confirm the base can is bonded/grounded before reconnecting the loop.
Engineering & Expert Notes
Orientation Errors Are Invisible From Directly Above
ComplianceA unidirectional optic installed rotated 180° can look correctly seated to a technician standing over the open base can, since the mechanical fit doesn't visibly indicate optical direction; verify orientation against a directional reference mark or by sighting down the runway, not by the housing's fit alone.
Colour-Zone Boundaries Are a System Property, Not Per-Fixture
ComplianceThe transition points between white, alternating red/white, and all-red zones are set by distance-to-go, so a single mis-zoned lamp doesn't just look wrong locally, it shifts the perceived remaining-runway cue for that whole stretch. Keep an as-built zone map on hand during relamping.
Flush Fit Matters as Much as Photometrics
MechanicalAn inset fixture sitting even slightly proud of grade becomes a snag or FOD risk for aircraft tyres well before it fails photometrically; verify flush seating against the surrounding runway grade at every reinstall, not just light output.
Trend Loop Readings, Don't Just Spot-Check
TroubleshootingMoisture ingress at an L-823 connector usually shows up first as a slow drift in loop insulation resistance, not a hard fault. Logging megger readings over successive maintenance cycles catches a failing splice months before it takes the loop down.
Size the Transformer to the Load, Not the Legacy Lamp
ElectricalReusing an isolating transformer sized for the old incandescent wattage on a much lower-draw LED fixture is a common source of premature transformer failure and nuisance loop trips; re-select VA rating against the actual LED load rather than assuming the existing transformer is "close enough."
Balance Loops Sharing One CCR
DesignWhere multiple series loops run off a single CCR, unequal loop lengths or lamp counts between loops can produce visibly uneven brightness even though each individual fixture tests within photometric tolerance. Balance loop impedance at the design stage, not after commissioning complaints.
Frequently Asked Questions
Short answers about unidirectional runway centreline lights: use, colour zones, spacing, standards, maintenance and common faults.
Q1What is a unidirectional runway centreline light?
It is an inset fixture that emits light in only one direction along the runway centreline, oriented towards approaching aircraft. It helps aircraft track the centre of the runway during landing roll and take-off.
Q2Where are unidirectional centreline lights used?
On runways where the main approach and take-off direction is fixed, for example because of prevailing winds or terrain constraints. On runways used both ways, a separately oriented set is needed for the other direction.
Q3What are the colour zones of runway centreline lights?
White from the threshold until 900 m before the runway end, alternating red and white from 900 m to 300 m before the end, and solid red for the last 300 m.
Q4How far apart are unidirectional centreline lights?
The page specifies 15 m (50 ft) intervals, the same spacing used across categories where centreline lighting is fitted. ICAO allows about 30 m on lower-category runways, so confirm against your regulator's requirements.
Q5How bright is a unidirectional centreline light?
Up to 10,000 cd for LED and 8,000 cd for halogen at 6.6 A, with 5 CCR steps from 2.8 A to 6.6 A and a beam of about 4° vertical by 6° horizontal.
Q6Are unidirectional centreline lights visible from the opposite end?
No, and that can be a safety concern if the runway is unexpectedly used in the opposite direction, for example during wind shifts. Airports should plan for this in their operating procedures.
Q7Which standards apply to unidirectional centreline lights?
The main references are ICAO Annex 14, FAA AC 150/5345-46, IEC TS 61827 and FAA Engineering Brief 67. Always verify the current edition.
Q8How often should unidirectional centreline lights be maintained?
Typical intervals are monthly lens cleaning, semi-annual beam alignment and colour filter checks, and annual seal and gasket inspection. Common faults are beam misalignment, filter fading and rubber contamination.
Related Components
Go Beyond the Component. Understand the Complete AGL System.
You have explored the component. Now understand how it works within the complete Airfield Ground Lighting system.
Learn AGL from fundamentals to design, installation, testing, photometry, commissioning, maintenance and troubleshooting through structured technical training at Precision AGL Academy.
Build practical knowledge. Understand the circuit. Read the standards. Troubleshoot with confidence.
Your next step in AGL starts here.
Need expert guidance on unidirectional centreline light selection or installation?
Precision AGL Academy provides advice on optical alignment, intensity requirements, and field testing of unidirectional AGL fixtures for single‑direction runways.
Follow the Academy
Important Notice, Disclaimer & Limitation of Liability
Please read before relying on any content on this page.
- Purpose and intended users. This page on Unidirectional Runway Centreline Light is an independent educational and informational reference for competent, suitably trained and authorised airfield ground lighting (AGL) and aerodrome electrical personnel. It is not professional engineering, legal or regulatory advice, and using it does not create any professional or client relationship.
- Safety. Work on series circuits, constant current regulators (CCRs), isolating transformers, cables, connectors and lighting equipment can be fatal. Always apply the aerodrome’s permit-to-work and isolation/LOTO procedures, prove dead, use correctly rated instruments and PPE, and follow the manufacturer’s instructions. Nothing here authorises work on live equipment or the bypassing of any safety device or interlock.
- Aviation operations. Nothing here authorises installation, modification, energisation, adjustment, return to service, a change of operating category (CAT I/II/III), a NOTAM or any aerodrome certification or approval decision. These rest with the aerodrome operator, the air navigation service provider and the competent regulator.
- Specifications, ratings and typical values. Descriptions, parameters, ratings, dimensions, photometric values, wattages, service lives, maintenance tasks and intervals, failure modes, certifications (for example CE, FCC, UL or IEC marks) and part or type designations are general, typical and indicative. They may not match any particular product, make, model or version, and they are not a datasheet, design, specification, selection, sizing, procurement or acceptance criterion. The manufacturer’s current documents, the approved design and the project specification prevail.
- Standards and regulations. References to ICAO, FAA, IEC, IEEE, ISO, BIS, DGCA and other standards are paraphrased summaries for orientation only. They may be incomplete or out of date, and standards are revised from time to time. Consult the current official editions. Following this content does not guarantee compliance with any law, standard or regulatory approval, and the regulator’s requirements always prevail.
- No warranty. Content is provided “as is” and “as available”, without warranty of any kind, express or implied, including accuracy, completeness, currency or fitness for a particular purpose. Real installations differ in design, equipment make and model, age and condition.
- Limitation of liability. To the fullest extent permitted by applicable law, Precision AGL Academy, Precision AGL Solutions and their owners, authors and contributors are not liable for any injury, death, loss, damage, downtime, penalty or regulatory consequence, whether direct or indirect, arising from the use of, reliance on, or inability to use this content. Nothing in this notice excludes or limits any liability that cannot lawfully be excluded or limited.
- Independence, brands and no endorsement. This is an independent publication. It is not affiliated with, sponsored by or endorsed by ICAO, the FAA, the IEC, DGCA, AAI, any airport, regulator, supplier or equipment manufacturer. Third-party names, product designations, standard designations and trademarks (including Megger®, Siemens, Eaton, Crouse-Hinds, ADB SAFEGATE, Fluke, ABB and Honeywell) belong to their respective owners and are used only for identification and description. Mention of a brand, product or supplier is not a recommendation, and we do not sell, supply or quote for any component described.
- Images and third-party content. Images and illustrations are shown to help identify the type of component. They may show products of various manufacturers, may not depict the exact item described, and are not a statement about any product’s quality, approval or performance. Copyright and trademarks in third-party images, logos and photographs belong to their respective owners and are not claimed as ours. If you are a rights holder and want an image removed, replaced or credited, email precisionaglsolutions@gmail.com with the page address and we will act promptly.
- Training and services. Mentions of training, courses, consultation, advice, selection, installation, calibration or other support, including the “Learn…Certify” pathway, describe learning stages and are not an offer, quotation, tender or promise of any result. Contacting us or our replying creates no engagement or duty of care; an engagement exists only under a written agreement. We are not a regulator or certification body, and completing any course or reading this content is not a certification, accreditation or authorisation to work on any aerodrome.
- Copyright, privacy and corrections. © 2026 Precision AGL Academy. All rights reserved. Text, structure, compilations and diagrams may be viewed for personal reference and internal training only; any other copying, republication or commercial use needs our written permission. If you email, telephone or message us, we use your details only to respond and handle your matter, in line with applicable Indian law including the Digital Personal Data Protection Act, 2023; please do not send confidential or security-sensitive information. To display this page your browser requests fonts, icons and images from third-party servers, which receive your IP address and browser details under their own policies. Content is reviewed periodically with no obligation to update. To report an error, safety concern or rights issue, write to precisionaglsolutions@gmail.com.