AGL photometric fault diagnosis — from low or excessive luminous intensity, uneven runs, beam misalignment and incorrect beam spread, through to distribution and chromaticity errors, wrong light colour, and the full range of measurement-side faults: instability, photometer calibration/zero/reference error, frame alignment, distance, height, mounting and orientation error, plus chronic-failure and visual/photometric-mismatch cases. Each topic follows the full engineering diagnostic record: symptom → observation → measurement → decision → fault location → root cause → verification → corrective action → preventive action.
Symptom — A fixture measures below the minimum specified luminous intensity (candela) at the design aiming angle during scheduled or acceptance photometric testing, even though the fixture illuminates and appears visually normal.
Runway/taxiway edge, centreline, or approach light fixture undergoing field or bench photometric verification against ICAO Annex 14 Attachment A / FAA AC 150/5340-30 isocandela curves.
After correction (module replacement, cleaning, or realignment), re-measure intensity at the full set of specified angles and confirm results meet or exceed the ICAO/FAA minimum curve, then log values into the fixture’s photometric history.
SOP: SOP-PHM-01 (Field Photometric Test Procedure), SOP-PHM-04 (Lamp/LED Module Replacement Procedure)
Standards: ICAO Annex 14 Vol I Attachment A, FAA AC 150/5340-30 (Design and Installation of Airport Visual Aids), FAA AC 150/5345-46 (Specification for Runway and Taxiway Light Fixtures)
Diagram: Isocandela Curve Reference Set
Case Study: Division 25 — Field Case Study Troubleshooting
Symptom — A fixture measures luminous intensity meaningfully above the specified maximum (or noticeably above sibling fixtures on the same circuit), producing glare complaints from pilots or unexpectedly high photometric readings during verification.
Approach, runway edge, or PAPI/VASI-adjacent AGL fixture under photometric test.
After correcting the module, CCR step, or calibration, re-measure and confirm intensity falls within the specified range across all commanded steps.
SOP: SOP-PHM-01, SOP-CCR-06 (CCR Output Calibration Procedure)
Standards: ICAO Annex 14 Vol I Attachment A, FAA AC 150/5340-30
Diagram: CCR Step/Intensity Reference Table
Case Study: Division 01 — CCR Troubleshooting
Symptom — Fixtures along the same run or circuit show significant variation in measured intensity between adjacent lights, even though each individually may pass or be near the specified minimum, producing a visually inconsistent runway/taxiway edge line.
A run/series of runway or taxiway edge, centreline, or approach lights on the same circuit or design section.
After standardising modules and/or correcting circuit voltage, re-survey the full run and confirm intensity variance falls within an acceptable band across all fixtures.
SOP: SOP-PHM-02 (Circuit Photometric Survey Procedure)
Standards: ICAO Annex 14 Vol I Attachment A, FAA AC 150/5340-30
Diagram: Circuit Layout and Voltage Profile Drawing
Case Study: Division 05 — Runway Centreline Light Troubleshooting
Symptom — Photometric testing shows the peak luminous intensity occurring at an angle offset from the design aiming point, even though total light output may be within specification.
Any directional AGL fixture (runway/taxiway edge, approach, PAPI) with a defined design aiming angle (elevation and azimuth).
After realignment (and mounting repair if applicable), re-survey the beam pattern and confirm the peak intensity occurs within the allowable angular tolerance of the design aiming point.
SOP: SOP-PHM-03 (Fixture Aiming and Alignment Procedure)
Standards: ICAO Annex 14 Vol I Attachment A, FAA AC 150/5340-30
Diagram: Fixture Aiming Template/Isocandela Reference
Case Study: Division 09 — Approach Lighting System Troubleshooting
Symptom — The measured beam width (horizontal and/or vertical spread) is narrower or wider than the specification for the fixture type, even when peak intensity and aiming angle are correct.
Directional AGL fixture with a defined isocandela beam-spread envelope (e.g., elliptical or circular beam optics).
After replacing the optic or correcting module seating, re-scan the beam pattern and confirm the horizontal and vertical spread fall within the specified isocandela envelope.
SOP: SOP-PHM-05 (Optical Assembly Inspection and Replacement Procedure)
Standards: ICAO Annex 14 Vol I Attachment A, FAA AC 150/5345-46
Diagram: Fixture Beam-Spread Isocandela Envelope
Case Study: Division 09 — Approach Lighting System Troubleshooting
Symptom — The overall isocandela pattern (shape of the intensity distribution across angles) does not match the specified curve for the fixture category, even though peak intensity, aiming, and beam spread individually may appear close to normal.
Any AGL fixture undergoing a full photometric distribution verification against its ICAO/FAA category curve.
After replacing the fixture or correcting the contributing faults, re-scan the full distribution and confirm it matches the specified isocandela curve within tolerance across all angles.
SOP: SOP-PHM-01, SOP-PHM-06 (Full Distribution Verification Procedure)
Standards: ICAO Annex 14 Vol I Attachment A, FAA AC 150/5340-30
Diagram: Isocandela Curve Reference Set
Case Study: Division 25 — Field Case Study Troubleshooting
Symptom — The fixture’s measured chromaticity coordinates fall outside the specified CIE colour box for its designated colour (e.g., white, red, yellow/amber, blue, green), even though the light appears approximately the correct colour to the eye.
Any colored AGL fixture undergoing chromaticity verification per ICAO Annex 14 Attachment A colour boxes.
After replacing the lens/filter or module, re-measure chromaticity and confirm the coordinates fall within the specified ICAO Annex 14 colour box.
SOP: SOP-PHM-07 (Chromaticity Verification Procedure)
Standards: ICAO Annex 14 Vol I Attachment A (Colours for Aeronautical Ground Lights), FAA AC 150/5345-46
Diagram: CIE Colour Box Reference Chart
Case Study: Division 25 — Field Case Study Troubleshooting
Symptom — The fixture displays an obviously incorrect colour to visual inspection (e.g., showing white where yellow/amber is required, or red where green is required), distinct from a subtle chromaticity shift.
Any coloured AGL fixture, typically at a runway/taxiway intersection, threshold, or caution zone where colour coding is safety-critical.
After fitting the correct-colour lens/filter/module, visually confirm correct colour display and verify chromaticity coordinates fall within the specified colour box.
SOP: SOP-PHM-08 (Fixture Colour Verification Procedure), SOP-PHM-07
Standards: ICAO Annex 14 Vol I Attachment A, FAA AC 150/5340-30
Diagram: Airfield Lighting Colour-Coding Layout
Case Study: Division 25 — Field Case Study Troubleshooting
Symptom — Repeated photometric readings on the same fixture, under apparently stable conditions, fluctuate significantly between successive measurements rather than settling to a consistent value.
Fixture under test together with the field photometer/measurement setup.
After correcting the identified cause, repeat the measurement series and confirm readings converge to a consistent value within the photometer’s stated accuracy.
SOP: SOP-PHM-01, SOP-PHM-09 (Photometer Setup and Stability Verification Procedure)
Standards: ICAO Annex 14 Vol I Attachment A, IES LM-79 (Electrical and Photometric Measurements of LED Products)
Diagram: Field Photometer Setup Reference
Case Study: Division 25 — Field Case Study Troubleshooting
Symptom — A field photometer produces readings that are suspected or confirmed to be inaccurate — consistently high, low, or inconsistent with a reference standard — potentially affecting the validity of fixture acceptance test results.
Field/portable photometer or luminance meter used for AGL photometric verification.
After recalibration or repair, re-verify the instrument against the reference source and confirm readings fall within the manufacturer’s stated accuracy before returning it to service.
SOP: SOP-PHM-10 (Photometer Calibration and Verification Procedure)
Standards: ICAO Annex 14 Vol I, IES LM-79, ISO/IEC 17025 (calibration laboratory competence, where applicable)
Diagram: Instrument Calibration Tracking Log
Case Study: Division 25 — Field Case Study Troubleshooting
Symptom — The photometer reads a non-zero value with no light source present (dark/zero reading check), indicating a baseline offset that will bias every subsequent measurement.
Field photometer/luminance meter sensor and readout unit.
After correcting the zero-check procedure or servicing the instrument, confirm a stable near-zero dark reading before proceeding with fixture measurements.
SOP: SOP-PHM-09, SOP-PHM-10
Standards: ICAO Annex 14 Vol I, IES LM-79
Diagram: Field Photometer Setup Reference
Case Study: Division 25 — Field Case Study Troubleshooting
Symptom — Photometric results are inconsistent with expected values because the reference standard, reference fixture, or reference dataset used for comparison is itself incorrect, outdated, or mismatched to the fixture under test.
Reference light source, reference fixture, or reference isocandela dataset used during acceptance or comparative photometric testing.
After correcting the reference used, re-evaluate the original fixture measurement against the verified-correct reference and confirm whether a genuine discrepancy remains.
SOP: SOP-PHM-01, SOP-PHM-11 (Reference Standard Control Procedure)
Standards: ICAO Annex 14 Vol I Attachment A, FAA AC 150/5340-30
Diagram: Isocandela Curve Reference Set
Case Study: Division 25 — Field Case Study Troubleshooting
Symptom — Photometric readings are inconsistent or biased because the photometer’s own measurement frame/mounting rig is not correctly aligned relative to the fixture’s optical axis or the runway/taxiway reference plane.
Photometer mounting frame, tripod, or measurement rig used to position the sensor relative to the fixture under test.
After correcting frame alignment, repeat the affected measurements and confirm results are consistent with a properly aligned setup.
SOP: SOP-PHM-09, SOP-PHM-12 (Measurement Frame Setup and Alignment Procedure)
Standards: ICAO Annex 14 Vol I, IES LM-79
Diagram: Field Photometer Setup Reference
Case Study: Division 25 — Field Case Study Troubleshooting
Symptom — Photometric readings are biased high or low because the actual distance between the photometer sensor and the fixture under test differs from the distance assumed in the test procedure or intensity calculation.
Field photometer and the distance-measurement method (tape, laser rangefinder, or fixed test-station geometry) used during fixture testing.
After correcting the distance and repeating the measurement, confirm the resulting intensity value is consistent with a correctly-distanced test.
SOP: SOP-PHM-01, SOP-PHM-13 (Measurement Distance and Geometry Verification Procedure)
Standards: ICAO Annex 14 Vol I, IES LM-79
Diagram: Field Photometer Setup Reference
Case Study: Division 25 — Field Case Study Troubleshooting
Symptom — Photometric readings are biased because the photometer sensor height above the pavement (or above the fixture’s optical centre) differs from the height specified in the test procedure.
Photometer mounting frame/tripod height setting relative to the fixture under test.
After correcting the height and repeating the measurement, confirm the resulting intensity value is consistent with a correctly-heighted test.
SOP: SOP-PHM-09, SOP-PHM-13
Standards: ICAO Annex 14 Vol I, IES LM-79
Diagram: Field Photometer Setup Reference
Case Study: Division 25 — Field Case Study Troubleshooting
Symptom — Photometric readings are unreliable or inconsistent because the photometer itself is not securely or correctly mounted, independent of frame alignment, distance, or height issues already ruled out.
Photometer body-to-frame mounting hardware and connection.
After correcting the mounting, repeat the affected measurements and confirm results are consistent and stable with a securely mounted instrument.
SOP: SOP-PHM-09, SOP-PHM-12
Standards: ICAO Annex 14 Vol I, IES LM-79
Diagram: Field Photometer Setup Reference
Case Study: Division 25 — Field Case Study Troubleshooting
Symptom — Readings are inconsistent with expected values because the photometer sensor’s rotational orientation (relative to the fixture’s designed horizontal/vertical reference axes) is incorrect, distinct from frame azimuth or mounting seating issues already ruled out.
Photometer sensor orientation relative to the fixture’s defined horizontal and vertical measurement axes.
After correcting orientation, repeat the measurement or full scan and confirm results align with the expected distribution for the fixture’s design axes.
SOP: SOP-PHM-09, SOP-PHM-12
Standards: ICAO Annex 14 Vol I Attachment A, IES LM-79
Diagram: Field Photometer Setup Reference
Case Study: Division 25 — Field Case Study Troubleshooting
Symptom — A specific fixture or fixture type repeatedly fails photometric acceptance testing across multiple visits or replacement attempts, despite individual corrective actions appearing successful at the time.
A recurring-failure fixture, its circuit, and its maintenance/test history.
After addressing the identified systemic cause, monitor the fixture’s photometric performance over the following one to two maintenance cycles and confirm no recurrence of the failure pattern.
SOP: SOP-PHM-01, SOP-PHM-14 (Chronic Fault Escalation Procedure)
Standards: ICAO Annex 14 Vol I, FAA AC 150/5340-30
Diagram: Fixture Maintenance History Log Template
Case Study: Division 25 — Field Case Study Troubleshooting
Symptom — A fixture appears completely normal on visual inspection (correct colour, no visible damage, illuminates as expected) yet fails one or more parameters during formal photometric testing.
Any AGL fixture where visual inspection alone was previously used as the primary field assessment.
Once the specific failed parameter is corrected per its dedicated diagnostic procedure, re-run the full photometric test and confirm the fixture passes on all parameters.
SOP: SOP-PHM-01; cross-reference PHM-451 through PHM-458 and PHM-459 through PHM-467
Standards: ICAO Annex 14 Vol I Attachment A, FAA AC 150/5340-30
Diagram: Isocandela and Colour Box Reference Set
Case Study: Division 25 — Field Case Study Troubleshooting
Symptom — A fixture measures fully within specification on formal photometric testing, yet appears visually abnormal in the field — for example, looking dim, oddly coloured, or unevenly lit compared to neighbouring fixtures under night operating conditions.
A fixture with a passing photometric test result but a reported or observed field appearance discrepancy.
If a genuine discrepancy is found and corrected, re-test under the matched condition and confirm the appearance concern is resolved; if no discrepancy is found, document the investigation and monitor for recurrence.
SOP: SOP-PHM-01; cross-reference PHM-453, PHM-451 through PHM-458
Standards: ICAO Annex 14 Vol I Attachment A, FAA AC 150/5340-30
Diagram: Isocandela Curve Reference Set
Case Study: Division 25 — Field Case Study Troubleshooting
Quick answers about AGL Photometry troubleshooting in the AGL Troubleshooting Atlas.
Division 18 is the AGL Photometry Troubleshooting reference. It publishes 20 diagnostic topics, PHM-451 to PHM-470, for AGL Photometry faults on airfield ground lighting systems.
Every topic follows the same diagnostic record: the symptom, equipment/system, possible causes ranked by likelihood (high, medium or low), required tools, safety precautions, diagnostic procedure, test points, root cause verification, corrective action, preventive action and related references (SOPs, standards, diagrams and case studies).
The 20 topics are PHM-451 to PHM-470: Low Light Intensity; Excessive Light Intensity; Uneven Light Intensity; Beam Misalignment; Beam Spread Incorrect; Incorrect Photometric Distribution; Incorrect Chromaticity; Wrong Light Color; Photometry Measurement Instability; Photometer Calibration Problem; Photometer Zero Error; Photometer Reference Error; Frame Alignment Error; Measurement Distance Error; Measurement Height Error; Instrument Mounting Error; Incorrect Measurement Orientation; Repeated Photometry Failure; Fixture Passes Visual Inspection but Fails Photometry; Fixture Passes Photometry but Field Appearance Abnormal.
Each procedure starts with observation before any intervention. For example, PHM-451 (Low Light Intensity) begins: Confirm the fixture is otherwise operating normally (no flicker, correct colour) and re-verify the isocandela specification and measurement angle applicable to this fixture type and category.
Each topic lists its own precautions. For example, PHM-451 (Low Light Intensity) starts with: Coordinate runway/taxiway closure or NOTAM before conducting field photometry that requires close approach to in-pavement fixtures.
Related references in the topics include SOP-PHM-01 (Field Photometric Test Procedure), SOP-PHM-04 (Lamp/LED Module Replacement Procedure), SOP-CCR-06 (CCR Output Calibration Procedure), SOP-PHM-02 (Circuit Photometric Survey Procedure), SOP-PHM-03 (Fixture Aiming and Alignment Procedure), SOP-PHM-05 (Optical Assembly Inspection and Replacement Procedure), SOP-PHM-06 (Full Distribution Verification Procedure) and SOP-PHM-07 (Chromaticity Verification Procedure), and 7 more.
Where a standard applies, it appears in the topic's Related References. Those cited in this division include ICAO Annex 14 Vol I Attachment A, FAA AC 150/5340-30, FAA AC 150/5345-46, ICAO Annex 14 Vol I and ISO/IEC 17025.
Use the search box at the top of the page to filter the 20 published topics by code, fault name or keyword; matching topics open automatically. Each diagnostic record can also be downloaded as a Word (.doc) file.
A photometric shortfall can come from a dirty lens, a misaligned fixture, an aging LED, or a dozen other causes.
Build the technical knowledge to understand light output degradation, beam pattern anomalies, and how to systematically trace a photometric failure back to its physical or electrical cause.
Diagnose systematically. Understand the circuit. Build real AGL expertise.