What is a pavement temperature sensor?

The probe or infrared sensor that measures the temperature of the runway and taxiway surface — and why the pavement can be below freezing while the air is not, and how the sensor shares the pavement with the lighting.

HOW IT MEASURES probe in the surface, or infrared WHY IT MATTERS a clear night, air versus pavement WHERE IT SITS in the pavement, runway plan view flush probe infrared sensor sub-surface probe measures the surface, not the air probe flush, cable in a duct 0 °C TEMP air temperature pavement temperature frost or ice time, evening to dawn air stays above 0, pavement falls below ice can form while the air looks safe cabinet LANDING DIRECTION TDZ MID STOP END shares the pavement with the centreline lights and their cables SIGNAL CHAIN Pavement probes + infrared sensor Surge protection + junction box Surface weather unit / AWOS Ops · ATC display + winter alerts
landing direction and cable run
air and pavement temperature
signal flow to the users
The Fact ICAO Annex 14 · Doc 9981 · winter operations

A pavement temperature sensor measures the temperature of the runway or taxiway surface, and often of the layer below it. It is either a probe set flush in the pavement or an infrared sensor on a pole that looks at a spot on the surface. Some units also report whether the surface is dry, wet, icy or treated. The pavement can be below 0 °C while the air is still above it.

On clear, calm nights the pavement loses heat by radiation and can cool faster than the air. When the surface is below 0 °C and at or below the dew point, frost or ice can form; a wet surface below 0 °C can also freeze whatever the dew point. Winter operations teams use the readings, with the air temperature and dew point from the weather station, to decide on anti-icing, de-icing and runway condition action.

The sensor shares the pavement with the in-pavement lights, base cans and ducts, and frost and ice also affect the lights themselves. A probe that is not flush, or a cracked seal, is a hazard to aircraft tyres and lets water in, so installation is coordinated with the lighting and civil works. The air temperature probe is entry 15 of the weather-sensing division.

MeasuresPavement surface temperature, often sub-surface too
Sensor typesEmbedded contact probe or infrared sensor
PlacementIn the pavement at representative positions, flush with the surface
ReportsTemperature in °C; some units also surface condition
Used forFrost and ice warning, anti-icing and de-icing decisions
LinkWeather station and winter operations
InstallationSealed, cable in conduit, kept apart from AGL series cable
MaintenanceCheck seal and surface; reinstate after resurfacing
Schematic; not to scale, and the curves show the trend only. A pole-mounted infrared sensor beside the pavement must be frangible and sited to meet the obstacle-limitation and runway-strip requirements of ICAO Annex 14 Vol. I. Positions, sensor type, calibration and use of readings follow the aerodrome’s winter operations procedures, the current ICAO Annex 14 and Doc 9981, and the manufacturer’s instructions.
Surface temperature
Temperature of the pavement top; the key value for frost and ice.
Sub-surface temperature
A probe below the surface shows how fast the pavement is cooling.
Frost risk
Surface below 0 °C and at or below the dew point.
Not air temperature
The air probe is entry 15 of the weather-sensing division.
Entry 12 · Lightning detector Full Index · Division 27

Frequently Asked Questions

Q1What does a pavement temperature sensor measure?

It measures the temperature of the runway or taxiway surface, and often of the pavement a few centimetres below it. Some units also report the surface condition, such as dry, wet, icy or treated with chemicals. It is a different instrument from the air temperature probe, because the pavement and the air can be at quite different temperatures.

Q2How do contact and infrared sensors differ?

A contact sensor is a probe set flush in the pavement, sealed in, with its cable in a duct. It measures the pavement it sits in. An infrared sensor is mounted on a pole beside the pavement and looks at a spot on the surface without touching it, so it needs no pavement cutting but needs a clear line of sight and a clean lens. Many aerodromes use embedded probes, sometimes with an infrared unit as a cross-check.

Q3Why not just use the air temperature?

On clear, calm nights the pavement loses heat by radiation and can fall below 0 degrees Celsius while the air a metre above it is still above freezing. Frost or ice can then form on the surface even when the air temperature looks safe. The pavement temperature, together with the dew point from the weather station, tells winter operations teams whether frost or ice is likely.

Q4Where are the sensors placed?

In the runway and taxiway pavement at representative positions, often at the touchdown zone, the mid-point and the stop end, and on key taxiways. The aerodrome and the meteorological authority decide the positions. Probes are placed where they represent the pavement but where wheel loads and snow clearing will not damage them, and they must sit flush with the surface.

Q5How does it connect to the AGL system?

It shares the pavement with the in-pavement lights, base cans and ducts, so the installation is coordinated with the lighting. It is not part of the series circuit, and its cable must be kept separate and recorded like any other airfield cable. Ice and frost on the surface also affect the lights themselves, which is one reason the readings are useful to the lighting maintenance team.

Q6What goes wrong?

Typical faults are a probe that is not flush or has a cracked seal, water in the cable or connector, damage during resurfacing or snow clearing, a dirty or iced infrared lens, calibration drift and a wrong position that does not represent the pavement. A probe left standing above the surface is also a hazard to aircraft tyres and a damage risk, so it needs the same care as an inset light.

Q7Is it safe to work on?

Work in the pavement needs the aerodrome's permit-to-work and aircraft-movement controls, and usually a runway or taxiway closure. Before cutting or drilling, locate and mark the AGL cables and ducts so they are not damaged. Because the readings affect winter operations decisions, tell the airside operations team and the meteorological authority before taking a sensor out of service.

Precision AGL Academy

See It. Understand It. Then Learn How to Engineer It.

Recognising an AGL system visually is the first step. The next step is knowing how to design, install, test, commission and maintain them correctly.

Build Practical AGL Engineering Skills

Go deeper with structured training from Precision AGL Academy, covering:

AGL Fundamentals Design & Electrical Engineering Approach Lighting Photometry Installation & Commissioning Maintenance & Troubleshooting

Learn how each light, sign and circuit works as part of a complete airport lighting system, not just as an isolated diagram.

See. Understand. Apply. Engineer.