Junction Pit
Provides an underground or accessible field infrastructure point for cable connection and maintenance.
View DetailsProtected access point for field cable connection and distribution
Junction boxes for protected airfield lighting cable connections, maintenance access and field electrical infrastructure.
Junction boxes provide protected access points for field cable connection and distribution within an Airfield Ground Lighting (AGL) installation.
They provide a controlled enclosure for cable terminations, connections and equipment interfaces while helping protect electrical components from environmental and mechanical conditions.
Precision AGL Solutions supplies junction-box configurations selected according to cable type, connection requirements, enclosure conditions, mounting arrangement and project-specific installation requirements.
Select the appropriate junction-box configuration according to the electrical circuit and installation environment.
| Parameter | Specification |
|---|---|
| Product Type | AGL junction box |
| Application | Field cable connection and distribution |
| Enclosure Material | Configuration dependent |
| Dimensions | Project/configuration dependent |
| Cable Entries | Number and size as specified |
| Terminal Arrangement | Project/circuit dependent |
| Sealing | Configuration dependent |
| Ingress Protection | As specified for installation |
| Mounting | Surface, structure or other approved arrangement |
| Cable Compatibility | Primary/secondary cable as applicable |
| Operating Environment | Airfield and outdoor installation conditions |
Exact enclosure dimensions, cable-entry sizes, terminal configuration and ingress-protection rating should be confirmed for the selected model and project application.
The enclosure construction should be appropriate for its intended location and exposure conditions.
Cable-entry positions should provide sufficient clearance for installation, termination and future maintenance.
Configure the internal terminal arrangement according to the intended electrical function, and clearly identify it in coordination with the approved electrical drawings.
Where used within an AGL primary circuit, select the junction box for compatibility with the circuit arrangement and cable system. Considerations:
For high-voltage AGL primary circuits, review the complete connection arrangement as a system rather than selecting the enclosure independently. Primary series-circuit connections are normally made with approved splice or L-823 connector assemblies rather than general-purpose terminal blocks, and the enclosure must never be opened while the series circuit is energised.
Junction boxes may also be used for selected secondary cable and equipment-interface applications. Selection should consider:
The arrangement should be compatible with the associated isolating transformer, fixture lead or field equipment.
Determine the required ingress-protection level from the installation location and project specification.
The mounting method should provide adequate mechanical support while maintaining access for cable installation and maintenance. Within the movement area or runway strip, boxes must not become an obstacle: use below-grade installation (for example in a pit) or a frangible arrangement, as the aerodrome design requires.
Consider access during the initial installation rather than after the box has been permanently positioned.
The installation should follow the approved electrical drawings and project installation procedures.
Carry out any electrical testing using the applicable project commissioning and safety procedures.
This helps determine whether the replacement can use the existing installation arrangement or requires modification.
WARNING — never open a live series circuit. An open series circuit driven by a constant-current regulator can produce dangerously high voltage. Opening, cutting or disconnecting any part of an energised circuit can cause serious injury or death and damage equipment.
Use the edition current at the time of your project.
Applicable requirements depend on the electrical circuit, enclosure location, cable system and project specification. Coordinate junction-box selection with the applicable AGL electrical requirements, cable and connector specifications, enclosure requirements and approved project documentation.
An AGL junction box is a protected enclosure that gives an access point for field cable connection and distribution within an Airfield Ground Lighting installation. It provides a controlled enclosure for cable terminations, connections and equipment interfaces while protecting electrical components from environmental and mechanical conditions.
They are used for primary and secondary field cable connections, field cable distribution, equipment interfaces, connection points within lighting systems, cable transition points, maintenance and inspection installations, new AGL infrastructure and rehabilitation projects.
A junction box provides protected above-ground or equipment-level field cable connections, whereas a junction pit provides underground access to cable joints, connectors and field electrical equipment. See the AGL junction pit page for the underground option.
Where used within a primary circuit, select it for compatibility with the series-circuit arrangement, cable construction, operating current, connector system and insulation requirements, and review the complete connection arrangement as a system. Primary series-circuit connections are normally made with approved splice or L-823 connector assemblies rather than general-purpose terminal blocks, and the enclosure must never be opened while the series circuit is energised.
Coordinate the cable diameter, the number of incoming and outgoing cables, glands or other entry arrangements, connector dimensions, bend radius, cable support and sealing around the entries. Entry positions should leave clearance for installation, termination and future maintenance. The internal terminal arrangement should match the electrical function, with earthing and bonding of metallic enclosures per the approved design, and be identified in coordination with the approved electrical drawings.
The enclosure and cable entries should protect against rain and water ingress, dust and contaminants, moisture and condensation, corrosive conditions, temperature variation and mechanical exposure. Determine the required ingress-protection level from the installation location and project specification, with IEC 60529 as the reference for IP ratings.
Options include surface mounting, equipment mounting structures, service-area mounting, junction-pit interfaces and other approved field mounting arrangements. The method should give adequate mechanical support while keeping access for cable installation and maintenance. Within the movement area or runway strip, boxes must not become an obstacle: use below-grade installation, for example in a pit, or a frangible arrangement, as the aerodrome design requires.
The box should let technicians inspect cable entries, check terminal connections, identify circuits, inspect sealing, check for moisture or contamination, verify cable condition and perform approved electrical tests. Consider access during the initial installation rather than after the box has been permanently positioned.
Before installation, verify the dimensions, cable types and quantities, cable-entry positions, terminal arrangement, enclosure material, ingress-protection requirement, mounting method, accessibility and identification requirements. At commissioning, inspect cable routing, terminations, circuit identification, cable-entry sealing, enclosure integrity, mounting, visible damage and electrical continuity where applicable.
Principal references are FAA AC 150/5345-42K (airport light bases, transformer housings, junction boxes and accessories), AC 150/5340-30J, ICAO Doc 9157 Part 5, IEC 60529, and DGCA India CAR Section 4 together with airport authority specifications. Use the edition current at the time of your project.
No. An open series circuit driven by a constant-current regulator can produce dangerously high voltage, and opening, cutting or disconnecting any part of an energised circuit can cause serious injury or death. De-energise the circuit at the regulator, apply the site lock-out / tag-out procedure, verify the circuit is de-energised and work under the permit-to-work system. See the electrical safety warning on this page.
Provide the existing junction-box dimensions, cable types and sizes, number of cable entries, existing terminal arrangement, mounting arrangement, environmental conditions, available installation space and photographs or drawings. This helps determine whether the replacement can use the existing installation arrangement or needs modification.
Indian public tenders commonly ask for the documents below. State which ones your tender requires when you send the enquiry, so they are covered in the quotation.
For junction-box selection, provide the application, cable type, cable quantity, cable dimensions, connection arrangement, installation location and required mounting configuration. Precision AGL Solutions can review the field connection requirements and help identify a suitable AGL junction box and associated cable-entry and termination arrangement.
Exact enclosure dimensions, cable-entry sizes, terminal configuration and ingress-protection rating should be confirmed for the selected model and project application. Coordinate junction-box selection with the applicable AGL electrical requirements, cable and connector specifications, enclosure requirements and approved project documentation.
Product availability, configuration, dimensions, electrical characteristics, photometric performance, certifications and compliance status depend on the selected manufacturer and project specification. The technical values published on this page should not be treated as a substitute for the manufacturer's current approved Technical Data Sheet.
Final selection shall be based on the approved project specification, applicable aviation standards, authority requirements, manufacturer documentation and site conditions. Use of this page is also subject to the Legal Notice, Disclaimer & Terms of Use.
Standards and editions referenced on this site are listed on the Standards Reference page.