Cable Identification Tags
Identification directly associated with cables and field connections.
View DetailsVisible identification of buried AGL services
Marker posts give visible identification of underground cable routes, infrastructure and selected equipment locations, helping maintenance personnel find buried AGL services and field connection points without relying solely on underground drawings or records.
Marker posts identify underground cable routes, infrastructure and selected airfield equipment locations. They are configured for the cable route, identification requirements, site conditions and project specifications.
| Parameter | Specification |
|---|---|
| Height | Project and visibility requirements dependent |
| Material | Selected according to application |
| Colour | Project and identification requirements dependent |
| Marking method | Printed, engraved, labelled or project specific |
| Identification | Cable route, circuit or infrastructure dependent |
| Foundation | Direct installation or suitable fixing arrangement |
| Environmental performance | Selected for outdoor airfield conditions |
| Installation | Route, junction and field infrastructure dependent |
Marker posts help maintenance personnel locate buried infrastructure during inspection, testing and repair. Identification can include relevant cable, circuit or infrastructure references per the project documentation.
Keep the marking arrangement consistent with the project's cable identification system.
Primary AGL series-circuit cables are commonly buried between CCR equipment, field transformers and associated lighting circuits. Markers at selected points indicate buried infrastructure and support maintenance.
Marker posts can identify selected secondary cable routes where route identification is required.
The identification system should correspond with the project's equipment and cable records.
Clear identification can reduce the time needed to locate underground infrastructure during maintenance.
The final legend and marking format should follow the approved project documentation.
Posts may face sunlight, rain, temperature variation, soil contact and routine airfield maintenance activities.
Installation should avoid interference with aircraft, vehicles, maintenance equipment and other airfield operations.
Marker posts give a reference for the approximate location of the crossing and support future maintenance or civil works.
Record the position accurately in the project's as-built documentation.
This creates a consistent identification system across the underground AGL infrastructure.
Replace damaged or missing posts according to the approved identification scheme. Position posts so they do not obstruct aircraft or vehicle operations.
Markers can be added or replaced during rehabilitation projects where existing underground cable identification is inadequate.
Coordinate with available cable drawings, survey information and verified field locations before installing new markers.
Primary AGL cables carry series-circuit current at up to 5,000 V insulation class. A post shows the route only. Before any excavation, follow the airport permit-to-work and cable-locate procedure, and never assume a marked cable is de-energised. Never cut or open an energised series circuit.
Equipment on the operational area must be frangible and mounted as low as its function allows (Annex 14, Vol. I, Chapter 9). Confirm with the airport before placing any post inside a runway or taxiway strip. Posts must not obstruct aircraft, vehicles, signs or lights, and must not be a substitute for accurate as-built records.
Height, material, colour, marking method, foundation and legend follow the site cable-marking system. Record every post in the as-built drawings.
Marker posts give visible identification of underground cable routes, infrastructure and selected equipment locations. They help maintenance personnel find buried AGL services and field connection points without relying solely on underground drawings or records.
Typical locations are primary and secondary cable routes, cable crossings, junction points, junction pits and handholes, cable joints, branch routes and equipment interfaces. The positions come from the approved drawings.
Possible information includes a cable or circuit reference, an equipment reference, route and junction identification, warning or service identification and project-specific coding. The legend and marking method, such as printed, engraved or labelled, should follow the approved project documentation and stay consistent with the project cable identification system.
Material selection should consider weather resistance, UV exposure, mechanical durability, visibility, corrosion resistance where applicable and long-term legibility of the markings. Posts may face sunlight, rain, temperature variation, soil contact and routine airfield maintenance activity, so height, material and colour follow the project and identification requirements.
Equipment on the operational area must be frangible and mounted as low as its function allows, as set out in Annex 14 Volume I Chapter 9. Confirm with the airport before placing any post inside a runway or taxiway strip, and make sure posts do not obstruct aircraft, vehicles, signs or lights.
No. Treat every marked cable as live. Primary AGL cables carry series-circuit current at up to 5,000 V insulation class, and a post shows the route only. Before any excavation, follow the airport permit-to-work and cable-locate procedure, and never cut or open an energised series circuit. See the safety and siting notes on this page.
Installation follows the approved drawings for route, marker-post location, required height, identification legend, material and colour, and the foundation or fixing arrangement. Confirm visibility from the required approach direction, clearance from aircraft and vehicle movement areas, and the position of existing underground services.
Buried cables are not visible after installation, so a post gives a reference for the approximate location of a crossing and supports future maintenance or civil works. Record the position accurately in the as-built documentation, because a post is not a substitute for accurate as-built records.
Check for damage or displacement, loose foundations, faded or illegible markings, corrosion or material deterioration, obstruction by vegetation or soil, and changes to surrounding infrastructure. Replace damaged or missing posts according to the approved identification scheme.
Yes. Markers can be added or replaced during rehabilitation projects where existing underground cable identification is inadequate. Coordinate with available cable drawings, survey information and verified field locations before installing new markers.
References include ICAO Annex 14 Volume I Chapter 9 on siting and frangibility of equipment, ICAO Doc 9157 Parts 5 and 6, FAA AC 150/5340-30J, FAA AC 150/5370-10 (Item L-108) on installation of underground airport power cable, and DGCA India requirements and the airport cable-records system. Height, material, colour, marking method, foundation and legend follow the site cable-marking system, and every post should be recorded in the as-built drawings.
Indian public tenders commonly ask for the documents below. State which ones your tender requires when you send the enquiry, so they are covered in the quotation.
Precision AGL Solutions can support marker-post selection based on cable route, identification requirements, marker dimensions, material, marking method and site installation conditions. Request your cable-marking requirements.
Product availability, configuration, dimensions, electrical characteristics, photometric performance, certifications and compliance status depend on the selected manufacturer and project specification. The technical values published on this page should not be treated as a substitute for the manufacturer's current approved Technical Data Sheet.
Final selection shall be based on the approved project specification, applicable aviation standards, authority requirements, manufacturer documentation and site conditions. Use of this page is also subject to the Legal Notice, Disclaimer & Terms of Use.