AGL Photometry Comparison

NEW FIXTURE PHOTOMETRY VS IN-SERVICE PHOTOMETRY

Baseline vs Actual Performance — new fixture photometry evaluates an AGL light when it is new and in its specified test condition, establishing the baseline/design performance. In-service photometry evaluates the photometric performance of a fixture that has been installed and operated over time, revealing its actual performance after operational exposure.

At a Glance

Feature New Fixture Photometry In-Service Photometry
Fixture conditionNewInstalled and used
Main purposeEstablish initial performanceAssess current performance
Ageing effectsAbsent or minimalIncluded
Dirt/contaminationNormally controlled/minimizedMay be present
Optical degradationNormally absentMay be present
Baseline comparisonYesCompared with baseline/specification
Installation effectsUsually excluded in fixture testingMay be included
Main question"How does a new fixture perform?""How is the fixture performing now?"
NEW
Baseline / Design Performance
IN-SERVICE
Actual Performance After Exposure

Establishing the Baseline

New Fixture Photometry

New fixture photometry establishes the initial optical performance of the AGL fixture. Typical characteristics assessed may include luminous intensity, peak intensity, beam distribution, horizontal coverage, vertical coverage, beam spread, and colour characteristics where applicable.

It essentially answers: "Does this new fixture provide the required photometric performance?"

New AGL Fixture
Photometric Test
Baseline Performance

Assessing Actual Performance

In-Service Photometry

In-service photometry assesses a fixture after it has been operating in the airfield environment. It answers: "Does the fixture still provide adequate photometric performance during service?"

Installed AGL Light
Operational Exposure
Dirt · Ageing · Wear
Photometric Test

What Started vs What It Delivers Now

Easy memory: New = what the fixture started with. In-service = what the fixture delivers now.

INITIAL
New Fixture → Baseline Performance
CURRENT
In-Service Fixture → Actual Performance

How Output Can Change Over Time

A new fixture may initially provide a specified peak intensity. After a period of operation, factors such as ageing may affect its output. The actual amount and cause of any change must be determined by measurement and should not simply be assumed.

New Fixture
10,000 cd
Peak intensity at baseline
In-Service Fixture
?
Current measured value

What Can Affect a Fixture in Service

An AGL fixture in service may experience a number of factors that can potentially affect its actual photometric performance:

How the Comparison Is Structured

This comparison can help identify whether photometric performance has changed during service:

New Fixture
Baseline / Reference Performance
In-Service Fixture
Current Photometry
Performance Comparison

Comparing Measured Intensity

Suppose a new AGL fixture has a measured centre-beam intensity of 10,000 cd. After a period in service, this is measured at 8,000 cd.

10,000 − 8,000 = 2,000 cd

Difference between the new and in-service measured intensity

2,000 / 10,000 × 100 = 20%

Percentage change from the new measured value

Therefore, the measured intensity has decreased by 20% relative to that baseline. Whether the fixture remains acceptable depends on the applicable specification, maintenance criteria, and measurement method.

Clean Baseline vs Actual Condition

New Fixture

Testing generally seeks to characterize the fixture under its defined test condition — clean, unweathered, as-manufactured.

In-Service Fixture

Its measurement can reflect its actual operational condition — dust, wear — unless the test procedure requires cleaning, removal, or other preparation before testing.

The test condition must always be defined before comparing new and in-service photometric results.

Fixture-Only Testing vs As-Installed Testing

New Fixture

New fixture photometry often focuses on the fixture itself, tested independently of its final installation.

In-Service Fixture

In-service photometry may involve the fixture as installed, so results may potentially include effects from alignment, mounting condition, installation geometry, electrical operating condition, and actual optical condition, depending on the measurement method.

Where Each Applies

Application Better Fit
Product developmentNew fixture photometry
Type testingNew fixture photometry
Initial qualificationNew fixture photometry
Establishing baseline performanceNew fixture photometry
Maintenance assessmentIn-service photometry
Detecting degradationIn-service photometry
Assessing operational conditionIn-service photometry
Comparing current vs initial performanceBoth

A Conceptual Illustration

NEW
Baseline performance
IN-SERVICE
Performance over time

This is only a conceptual illustration. Real fixtures may maintain stable performance, degrade gradually, or change differently depending on their technology, maintenance, and operating environment.

Comparable Conditions Are Essential

A meaningful comparison requires comparable conditions. Otherwise, a difference in results may be caused by the test setup rather than actual fixture degradation.

1

Same measurement geometry? Confirm the test setup matches between new and in-service measurements.

2

Same operating condition? Confirm the fixture is powered and operated equivalently.

3

Same measurement method? Confirm the instrument and procedure are consistent.

4

Comparable results. Only then can a difference be reasonably attributed to the fixture itself.

Full Engineering Parameters

Parameter New Fixture Photometry In-Service Photometry
Fixture ageNewOperational
Primary objectiveEstablish initial performanceVerify current performance
Baseline valueProvides itUses it for comparison
AgeingMinimalPotentially present
ContaminationUsually controlledMay reflect actual condition
WearMinimalPotentially present
Installation influenceOften excludedMay be included
Maintenance assessmentLimitedHighly useful
Degradation detectionReference pointPrimary application

Two Different Dimensions

These comparisons describe different dimensions. For example, you could have a new fixture tested in a laboratory, a new fixture verified in the field, an in-service fixture retested in a laboratory, or an in-service fixture tested in the field.

Test Location

Laboratory vs field describes where/how the measurement is performed.

Fixture Condition

New vs in-service describes the condition and service history of the fixture being measured.

New Fixture vs In-Service Photometry

Engineering Verdict

New fixture photometry establishes the initial/baseline optical performance. In-service photometry measures the current performance after operational use.

For AGL maintenance and lifecycle assessment, new-fixture photometry provides the reference performance, while in-service photometry reveals the fixture's actual optical performance after exposure to real operating conditions.

NewBaseline → "How good was it?"
In-ServiceCurrent test → "How good is it now?"

Engineering & Expert Notes

Keep the New-Fixture Data as the Baseline
Baseline

It makes in-service results meaningful.

Record Condition Before and After Cleaning
Preparation

This shows how much loss is reversible.

Match Settings and Geometry
Repeatability

Use the same step and positions.

Set Test Intervals From Trends
Planning

Adjust frequency by observed decline.

Frequently Asked Questions

What is the simplest way to remember the difference?

New fixture photometry → BASELINE (how good the fixture started out). In-service photometry → CURRENT (how good the fixture is performing now).

Does a lower in-service reading always mean the fixture has failed?

Not necessarily. Whether a measured difference is acceptable depends on the applicable specification, maintenance criteria, and measurement method — the amount and cause of any change should be determined by measurement, not assumed.

Should an in-service fixture be cleaned before testing?

That depends on the defined test procedure. The test condition must always be defined before comparing new and in-service photometric results, since an uncleaned fixture reflects actual operational condition while a cleaned one may not.

Can in-service results be affected by something other than the fixture itself?

Yes. As-installed measurements may include effects from alignment, mounting condition, installation geometry, and electrical operating condition, not just the optical condition of the fixture.

Is new-vs-in-service the same comparison as laboratory-vs-field photometry?

No. Laboratory vs field describes where/how a measurement is performed. New vs in-service describes the condition and service history of the fixture being measured — the two dimensions can be combined in different ways.

What causes in-service photometric performance to change?

Typical influences include dirt accumulation, lens contamination, optical ageing, LED ageing, lamp degradation, mechanical wear, vibration, and environmental exposure.

Governing Documents

For an actual project design, always verify the current edition of the applicable documents.

FAA AC 150/5345-46

Specification for Runway, Taxiway, Heliport, and Vertiport Light Fixtures — the actual fixture equipment specification, including the isocandela/photometric performance requirements a new fixture must meet at type approval.

FAA AC 150/5340-30

Design and Installation Details for Airport Visual Aids — photometric requirements relevant to interpreting new and in-service AGL performance.

ICAO Annex 14, Volume I

Aerodrome Design and Operations — photometric characteristics of aeronautical ground lights, including maintenance-related performance considerations.

CIE Photometry Standards

International Commission on Illumination definitions and measurement methods for luminous intensity and related photometric quantities.

Final Engineering Note

Do not compare new and in-service photometric results without first confirming the test condition, geometry, and method are comparable between the two measurements.

New fixture photometry is not in-service photometry — one describes the design baseline, the other describes what the fixture actually delivers in the field.

Precision AGL Academy

Compare the Systems. Then Learn How to Engineer Them.

Understanding the difference between AGL systems is the first step. The next step is knowing how to design, install, test, commission and maintain them correctly.

Build Practical AGL Engineering Skills

Go deeper with structured training from Precision AGL Academy, covering:

AGL Fundamentals Design & Electrical Engineering Approach Lighting Photometry Installation & Commissioning Maintenance & Troubleshooting

Learn how AGL systems work as part of a complete airport lighting system, not just as individual components or configurations.

Compare. Understand. Apply. Engineer.