CAT II Approach Lighting

A high‑integrity approach lighting system for Category II precision operations, featuring an enhanced configuration with additional barrettes, centreline lights, and red side‑row bars. It provides exceptional visual guidance for approaches down to a 100ft decision height and 300m RVR (or 350m depending on local regulations), enabling safe operations in challenging weather conditions.

CAT II Approach Lighting System

Image disclaimer: For identification and illustration only. It may show a product by another manufacturer and may not depict the exact item described; it is not a statement of any product’s quality, approval or performance. Third-party image and trademark rights belong to their owners. See full notice.

Overview

What Is It?

CAT II Approach Lighting is a precision approach lighting system designed to support Category II instrument approaches. It typically consists of a full 900‑metre configuration of barrettes, sequenced flashing lights, and additional red side‑row bars in the final approach segment. The system provides enhanced visual cues compared to CAT I, with extra centreline lights and barrettes to help pilots maintain precise alignment and glide slope during low‑visibility approaches. CAT II systems support operations with a decision height of 100 feet and RVR down to 300 metres (or 350 metres in some regions). They are essential for airports that experience frequent fog, rain, or snow.

Purpose

Purpose & Function

CAT II approach lighting exists to push the decision height down to 100 feet and the RVR minimum down to roughly 300 metres, a regime where the pilot has meaningfully less time and visual distance to confirm the runway environment than under CAT I, so the system compensates with extra centreline lights, barrettes, and red side-row bars in the final segment to concentrate visual information exactly where the pilot needs it most. The red side-row bars specifically exist to mark the final approach segment distinctly from the earlier portion of the approach, giving the pilot an unambiguous cue that they are entering the most visually critical final stretch before the decision point. Its purpose sits between CAT I's routine low-visibility support and CAT III's near-zero-visibility redundancy, calibrated to airports that need reliable operations through frequent fog, rain, or snow without requiring the most extreme (and expensive) level of system redundancy.

Application

Where Is It Used?

CAT II approach lighting systems are installed at airports that support Category II precision approaches. They are typically used on:

  • Precision approach runways with CAT II capability (100ft DH, 300m RVR minimum)
  • Major international hub airports with high traffic volumes and frequent low‑visibility conditions
  • Airports in regions with adverse weather (fog, heavy rain, snow)
  • Military airbases requiring all‑weather operational capability
  • Runways that serve as diversion airports for CAT II/III‑equipped aircraft
Placement

Installation & Location

Fixtures are set out along the extended runway centreline for the full 900 m length, on frangible stands graded to the approach slope; structures crossing roads, water, or depressions are elevated on piers or catwalks to keep the array on a consistent plane. The red side-row bars in the final 300 m are tied into the runway's own lighting so the transition from approach to runway reads as one continuous system. Because CAT II operations demand higher reliability, stands and cabling are typically arranged on independently fed circuits so a single fault cannot extinguish the full array, with cable runs in duct back to redundant constant current regulators. Setting-out follows the extended centreline and threshold survey to the same tolerance as the runway lighting it feeds into.

Function

How Does It Work?

The CAT II approach lighting system builds on CAT I with enhanced features for lower visibility:

  • Barrettes: A series of light bars (typically 3 to 5 lights per bar) positioned at 30m/100 ft intervals along the full 731m/914m (2,400 ft/3,000 ft) approach path, providing distance and lateral guidance.
  • Sequenced Flashing Lights (SFL): High‑intensity lights that flash in sequence from the outer end toward the threshold, creating a "rolling" effect that indicates the approach direction and helps pilots maintain the correct glide slope. The SFL in CAT II has higher intensity and faster flash rate for better visibility in fog.
  • Red Side‑Row Bars: Additional red lights installed on both sides of the approach path in the final 300m segment. These provide a visual warning if the aircraft deviates laterally from the centreline and help define the approach corridor.
  • Centreline Barrette: A short row of lights on the approach centreline, providing precise lateral guidance and helping pilots align with the runway.
  • Decision Bar: A row of lights at the decision height point, providing a visual reference for the pilot's go/no‑go decision.
  • Intensity Control: The entire system is controlled by CCRs with multiple intensity steps (typically 5 steps), with higher intensities used during low‑visibility conditions. The system may also include automatic dimming based on RVR data.
Architecture

System Architecture & Control Logic

As with CAT I, a CAT II installation runs two electrically independent control paths across the same 731m/914m corridor. Steady-burning elements — barrettes, red side-row bars, and centreline barrette — sit on a constant current series circuit: the ALCMS selects the intensity step based on RVR, ATC instruction, or automatic visibility-linked logic, the CCR regulates the whole loop to a single fixed current, and every steady fixture on that loop burns at the same brightness via its own isolating transformer. The sequenced flashing lights and decision bar are driven separately by a flasher/sequencer controller that discharges through each SFL lamp in strict outer-to-threshold order; in CAT II this sequencer runs at a higher flash rate and higher peak intensity than CAT I for better fog penetration. The ALCMS commands both subsystems in step together, but a fault in one does not propagate to the other, and each is fault-monitored independently by its own controller.

ALCMS commands both the steady CCR loop and the high-intensity SFL sequencer in step

AIRFIELD LIGHTING CONTROL SYSTEM (ALCMS) RVR-linked step selection, drives both subsystems together CONSTANT CURRENT REGULATOR Converts step command to fixed loop current STEADY-FIXTURE SERIES CIRCUIT LOOP Feeds barrettes, red side-rows & centreline together ISOLATING TRANSFORMER (PER FIXTURE) Taps fixed loop current to each steady fixture HIGH-RATE SFL FLASHER / SEQUENCER Capacitor-discharge, faster rate & higher peak than CAT I BARRETTES / SIDE-ROWS / CENTRELINE Steady-burning — all fixtures at one intensity SEQUENCED FLASHING LIGHTS + DECISION BAR Outer lamp to threshold, tuned for fog penetration APPROACH LIGHT PATTERN TO PILOT Steady bars and rolling flash combine into one visual cue TWO INDEPENDENT SUBSYSTEMS, RVR-LINKED IN STEP
Layout Logic

731m/914m Approach — Element Layout to Threshold

731m/914m 600m 300m Threshold Centreline Barrettes — 30m/100 ft Spacing, Full 731m/914m Length Red Side-Row Bars — Final 300m Decision Bar 100ft DH SFL — Sequenced Flashing "Rolls" Toward Threshold Runway CCR — 5-Step Control
Centreline barrettes / circuit
Red side-row bars
Decision bar
Runway threshold
Construction

Physical Construction

Barrette stands are frangible structures carrying multiple lamp housings on a rigid bar, graded in height to keep the array on the approach slope; die-cast aluminium housings behind toughened, gasket-sealed lenses achieve an IP67/IP68 rating on each lamp. The sequenced flashing heads use high-intensity xenon strobe tubes and trigger electronics housed in weatherproof domes, backed by capacitor banks at the base of each stand sized for the faster CAT II flash sequence. Red side-row bar fixtures in the final 300 m share the same die-cast, gasket-sealed construction as the runway's own edge lighting, so the approach hardware ties directly into the runway lighting system at the threshold. Where the approach crosses roads, water, or depressions, stands are raised on piers or catwalks engineered to keep the array coplanar, and because CAT II operations demand higher reliability, circuits are built with independent cabling and redundant isolating transformers so a single fault cannot take down the full array. Stainless-steel fasteners and corrosion-resistant finishes are used throughout.

Specification

Technical Parameters

ParameterTypical Value
System TypeCAT II precision approach lighting
Light SourceLED array or halogen (100W – 200W, high‑intensity)
ColourWhite (steady and flashing), Red (side‑row bars)
Configuration Length731 metres / 2,400 ft (standard) – 914 metres / 3,000 ft (shallow-slope sites)
Barrette Spacing30m/100 ft intervals along full length
Sequenced Flashing LightsHigh‑intensity, fast sequence (flashing toward threshold)
Side‑Row BarsRed lights on both sides of the final 300m segment
Decision BarPresent at decision height point
Intensity Steps5‑step (2.8A – 6.6A) CCR controlled, with automatic dimming capability
Beam PatternUni‑directional towards approach, narrow beam for high intensity
Mounting TypeElevated or flush‑mounted (inset)
Isolating Transformer100W – 200W (6.6A series circuit)
Protection ClassIP67 / IP68 (submersible)
SupportCAT II precision approach (100ft DH, 300m RVR typical)
Power Supply

Electrical Requirements

RequirementTypical Value
Circuit TypeIndependent series circuits (CCR fed) for centreline barrettes, red side-row bars, and SFL/strobe array
Rated Series Current6.6A per circuit (5-step: 2.8A / 3.4A / 4.1A / 5.2A / 6.6A)
IsolationDedicated isolating transformer (100W – 200W) per fixture; SFL heads fed from dedicated capacitor-discharge units
Transformer SecondaryMatched to fixture wattage; sized to series circuit rating
SFL Power SupplyHigh-output capacitor-discharge trigger units driving xenon strobes, synchronised by a flasher controller for the faster CAT II sequence rate
Cable TypeL-824 single-conductor, direct-burial rated, 5kV per circuit; shielded trigger cable for SFL synchronisation
ConnectorL-823 primary connector, submersible-rated splice
Insulation Resistance≥ 50 MΩ (megger test, cable-to-ground)
Earthing/GroundingFixture body, stands, and base cans bonded to airfield earth grid
Fault ProtectionCCR-level ground fault and open-circuit detection per circuit sector; SFL controller health monitoring
RedundancyIndependent cabling and duplicate isolating transformers per circuit sector to limit the effect of a single fault
Power SourceCCR output per circuit, regulated per ICAO/FAA RVR-based intensity step schedule, with automatic dimming
Optical Performance

Photometric Requirements

ParameterTypical Value
Centreline Barrette Intensity10,000 – 20,000 cd (white), 5-step: 100% / 30% / 10% / 3% / 1%
Red Side-Row Bar Intensity≥ 2,000 cd (red) over the last 1,000 ft to touchdown
SFL Peak Effective Intensity≥ 20,000 effective cd (white xenon strobe)
SFL Flash RateFast sequence rate synchronised outward-to-threshold along the centreline, per CAT II schedule
Vertical Beam SpreadMain beam 1°–12° above horizontal (peak ~2°–3°)
Horizontal Beam Spread± 4.5° either side of runway centreline extended, plus red side-row spread
ChromaticityWhite (centreline/SFL) and red (side-row bars) within ICAO Annex 14 boundaries
RVR-Based Intensity ControlAutomatic step selection tied to reported RVR, per ICAO Annex 14 CAT II tables
Isocandela DistributionPer ICAO Annex 14 Attachment A / FAA AC 150/5340-30 CAT II configuration figures
Compliance

Applicable Standards

ICAO Annex 14

CAT II approach lighting configuration, spacing, colour, and photometric requirements

FAA AC 150/5345-46

Specification for CAT II approach lighting components

IEC 61827

Electrical and photometric performance for AGL luminaires

FAA Engineering Brief #67

LED CAT II component performance requirements

Prerequisites

Installation Requirements

Frangible Stand Footing & Slope Grading
Civil

Set each stand footing along the full 900 m run to the design height so the array follows the approach slope, holding tolerance through to the threshold.

Elevated Piers & Catwalks Over Obstacles
Civil

Install piled structures or catwalks wherever the approach crosses roads, water, or depressions, engineered to keep the array coplanar.

Duct & Redundant Cable Routes
Electrical

Lay independently routed duct runs for the steady, high-intensity SFL, and red side-row bar circuits, keeping each on its own feeder so a single fault cannot extinguish the full array.

L-823 Connector Termination
Electrical

Terminate and seal primary connectors on every circuit per manufacturer procedure, keeping each splice fully submersible-rated before backfill.

Redundant Isolating Transformer Matching
Electrical

Confirm isolating transformer wattage and ratio match each circuit's rated current step, with steady, SFL, and side-row transformers kept on their independently fed loops.

Barrette, SFL & Side-Row Assembly
Mechanical

Fix lamp housings to barrette bars, mount SFL heads on their stands, and install red side-row bar fixtures in the final 300 m, torquing all frangible fittings to spec.

Setting-Out & Runway Transition
Mechanical

Tie stand positions to the extended centreline and threshold survey to the same tolerance as the runway lighting it feeds into, keeping the approach-to-runway transition continuous.

Pre-Energisation Sign-off
Documentation

Record stand positions, redundant cable routes, connector seals, and torque values as-built for every circuit before backfill, since these are not inspectable once the site is closed.

Verification

Testing & Commissioning

Insulation Resistance (Megger) Test
Pre-Energisation

Megger-test the steady circuit, the high-intensity SFL circuit, and the red side-row bar circuit separately before backfill, confirming each clears the acceptable minimum.

Loop Continuity & Resistance Test
Pre-Energisation

Verify series loop continuity and record total loop resistance for the full 731m/914m run, including the side-row bars, before first energisation.

Primary/Secondary Voltage Verification
Energisation

With the CCR energised, confirm secondary voltage at each barrette and side-row bar transformer matches the rated ratio at the commissioned current step.

Automatic RVR-Linked Dimming Verification
Energisation

Simulate a range of RVR inputs to the ALCMS and confirm the CCR automatically adjusts intensity in line with CAT II visibility-linked control logic.

Sequenced Flashing & Decision Bar Response
Energisation

Confirm the high-intensity SFL sequence fires correctly toward the threshold and that the decision bar illuminates and aligns with the decision-height reference point.

Side-Row Bar & Barrette Alignment Verification
Final Acceptance

Check elevation, azimuth, and colour segregation of every barrette and red side-row light against the design aiming diagram, correcting any deviation before sign-off.

Photometric Commissioning Test
Final Acceptance

Measure beam intensity and colour of white and red elements with a calibrated photometer against ICAO/FAA CAT II commissioning tolerances.

Documentation & As-Built Sign-off
Final Acceptance

Record insulation, continuity, voltage, dimming-response, and photometric readings alongside as-built positions in the commissioning dossier for handover.

Upkeep

Inspection & Maintenance

Photometric Intensity Check
Annual

Verify barrette, side-row bar, and centreline beam intensity against ICAO / FAA thresholds using a calibrated photometer across the full 731m/914m high-intensity configuration.

Barrette & Side-Row Lens Cleaning
Quarterly

Clear dust, insect residue, and weathering film from barrette, side-row, and centreline lenses so beam output stays within spec at CAT II intensity levels.

Sequenced Flasher Timing Test
Semi-annual

Confirm the high-intensity sequenced flashers fire in the correct rapid outer-to-threshold order, since a stuck or mistimed flasher undermines the approach cue at reduced visibility.

Decision Bar Function Check
Semi-annual

Verify the decision bar at the decision height point illuminates correctly and at the specified intensity, since this is the critical go/no-go visual reference for the crew.

Automatic Dimming / CCR Step Verification
Semi-annual

Confirm the CCR delivers the correct current at each of its 5 intensity steps and that automatic dimming responds correctly to commanded settings.

Seal & Gasket Inspection
Annual

Check top-cap O-rings and gaskets across elevated and inset fixtures for cracking or compression set, and re-torque fasteners to keep each unit watertight.

Insulation Resistance Test
Annual

Megger-test the isolation transformers and series circuit feeding the configuration to confirm resistance stays above minimum, flagging moisture ingress before it causes a circuit-wide fault.

Cable & Connector Inspection
Annual

Examine primary and secondary cable connections across the array for corrosion or loose crimps, a common source of intermittent series-circuit faults over a run this long.

Field Notes

Common Field Issues

Lens Contamination

CAT II components are exposed to severe environmental conditions, including fog, rain, snow, and de‑icing chemicals. Regular cleaning with approved solvents and soft brushes is essential to maintain light output and visibility, especially for the critical side‑row bars and SFL.

SFL Synchronisation Drift

The SFL system relies on precise timing. Control units can drift over time, causing the sequence to become irregular or out of sync. Regular calibration and testing of the SFL system is critical for CAT II operations.

Misalignment of Elevated Fixtures

Elevated approach lights can be knocked out of alignment by wind, wildlife, or maintenance vehicles. Regular alignment checks using a theodolite or laser alignment system are essential, especially for the side‑row bars which must be precisely positioned.

Red Filter Degradation

The red side‑row bars use colour filters that can degrade over time due to UV exposure and thermal stress. The red colour may fade or shift toward orange, reducing the effectiveness of the visual cue. Regular photometric testing and filter replacement are essential.

CCR and Power Supply Issues

CAT II systems draw significant power and require precise current regulation. Voltage fluctuations, CCR faults, or cable damage can cause inconsistent brightness or total failure. Regular power quality monitoring and cable testing are recommended.

Diagnostics

Troubleshooting Guide

Single Light/Bar Dark, Rest of Array Normal
Likely Cause
Failed lamp/LED source, or an open isolating transformer at that fixture (blown primary link or failed secondary winding).
Diagnostic Steps
Confirm series loop continuity through the fixture's transformer primary; megger the transformer; check secondary voltage at the connector with the CCR energised.
Corrective Action
Replace the lamp/LED source if the transformer checks healthy; otherwise swap the isolating transformer and re-seal the L-823 connectors before backfill.
Entire Array Dark / CCR Will Not Regulate
Likely Cause
Open-circuit fault in the series loop feeding the approach lights (severed cable, corroded splice, or a failed transformer acting as an open point).
Diagnostic Steps
Check the CCR fault/open-circuit indication first; loop-resistance test from the CCR output to isolate the faulted segment; sectionalise and megger cable runs along the approach centreline to narrow down the break.
Corrective Action
Excavate and repair or replace the faulted cable section and connector; re-test insulation resistance before reinstating the circuit.
SFL Sequence Irregular or Out of Step
Likely Cause
Timing drift in the sequenced flashing light controller, or a failed flasher unit, has broken the rolling flash pattern.
Diagnostic Steps
Verify controller timing against the specified sequence rate; check each flasher head in turn for correct firing order; inspect flasher control cabling for damage.
Corrective Action
Recalibrate or replace the SFL controller, or replace the faulty flasher head; confirm the rolling sequence is restored end to end.
Red Side-Row Bar Faded or Shifted Toward Orange
Likely Cause
UV exposure and thermal stress have degraded the red colour filter on a side-row bar, shifting its chromaticity out of tolerance.
Diagnostic Steps
Run a photometric/chromaticity check against ICAO colour limits for red; visually compare the suspect bar to a known-good reference fixture.
Corrective Action
Replace the red filter or lens assembly; re-verify chromaticity with a follow-up test before returning the bar to service.
CCR Trips on Overcurrent or Ground Fault
Likely Cause
Moisture ingress at a fixture or connector has degraded insulation resistance, creating a short or a partial ground fault on the series loop.
Diagnostic Steps
Megger the full circuit to identify the low-resistance segment; visually inspect suspect fixtures for cracked gaskets, condensation, or damaged secondary cable jackets.
Corrective Action
Dry out or replace the affected fixture/connector, renew O-rings and gaskets, and confirm insulation resistance is back above the acceptable minimum before re-energising.
Elevated / Side-Row Fixture Misaligned
Likely Cause
Wind loading, wildlife strike, or vehicle contact has knocked an elevated fixture or side-row bar off tolerance; side-row bars are especially sensitive since they must sit precisely relative to the centreline for CAT II operations.
Diagnostic Steps
Re-check fixture aim with a theodolite or laser alignment system against the approach centreline; inspect the frangible coupling and mounting stake for cracking or play.
Corrective Action
Re-level and re-aim the fixture, replace the frangible coupling if fatigued, and address any base or subgrade settlement to prevent recurrence.
Reliability

Failure Modes & Root Causes

Light Source (Lamp/LED) Failure
High Severity
Root Cause
Solder-joint fatigue from repeated thermal cycling, moisture ingress through a compromised fixture seal, or ordinary end-of-life lumen depreciation.
Effect
Single light or bar within the approach or side-row array goes dark or drops below minimum intensity while the rest of the array continues to operate normally.
Detection Method
Nighttime visual patrol along the approach centreline, periodic photometric intensity survey, and continuity/secondary-voltage checks at the fixture connector.
Isolating Transformer Winding Failure
High Severity
Root Cause
Moisture ingress leading to insulation breakdown, a manufacturing defect in the winding, or a blown primary fuse-wire link from a transient surge.
Effect
Open-circuit point in the series loop; can darken the single fixture or, if the open extends to the loop itself, take down the entire array or side-row circuit.
Detection Method
Megger test of the transformer, secondary voltage check with the CCR energised, and loop-resistance testing from the CCR output.
L-823 Connector / Splice Degradation
Medium Severity
Root Cause
Improper seating or crimping during installation, gasket failure allowing groundwater ingress, or corrosion building up on the pins over time.
Effect
Intermittent operation, flickering, or a partial ground fault that degrades circuit insulation resistance.
Detection Method
Insulation resistance (megger) testing of the circuit and visual inspection of connectors at each fixture base can during maintenance.
Series Cable Insulation Breakdown
High Severity
Root Cause
Cable jacket damage from nearby excavation or wildlife activity, age-related insulation degradation, or prolonged standing water in the duct run.
Effect
Ground fault or short circuit that trips the CCR or darkens the entire series loop feeding the approach, side-row, or decision bar circuits.
Detection Method
Full-circuit megger test to flag the low-resistance segment, followed by sectionalised testing or time-domain reflectometry to pinpoint the fault location.
Elevated / Side-Row Fixture Frangible Coupling Fatigue
Medium Severity
Root Cause
Cyclic wind loading, wildlife strike, or contact from a maintenance vehicle, combined with ordinary material fatigue over the service interval.
Effect
Fixture leans, loosens, or separates from its mounting stake, pulling the light out of aim tolerance and distorting the side-row or decision bar reference required for CAT II minima.
Detection Method
Physical inspection for cracking or play in the coupling, and periodic fixture-aim checks with a theodolite or laser alignment system.
CCR Regulation Fault / Automatic Dimming Step Fault
High Severity
Root Cause
Internal component failure (control board or output stage), a load mismatch after circuit modification, or a fault in the automatic dimming step logic tied to reported visibility.
Effect
Incorrect brightness step for prevailing RVR conditions, failure to hold regulated current across the loop, or nuisance tripping on an otherwise healthy circuit.
Detection Method
CCR self-diagnostic/fault indication, output current verification, and a load-bank test to confirm regulation and correct step selection across all intensity levels.
Red Filter Degradation (Decision Bar & Side-Row Bars)
Low Severity
Root Cause
Prolonged UV exposure and heat cycling causing the red filter material to fade, combined with grime build-up on the outer lens surface.
Effect
Red output on the decision bar or side-row bars fades or shifts toward orange, weakening the decision-height cue the bars are meant to provide under CAT II approach conditions.
Detection Method
Scheduled photometric colour and intensity testing against the required red chromaticity range, and visual inspection of filters during quarterly cleaning.
SFL Synchronisation Drift / Flasher Failure
Medium Severity
Root Cause
Ageing capacitor bank in the condenser discharge unit, a failed trigger transformer, or timing drift in the sequenced flashing light controller.
Effect
Flasher fails to fire or fires out of sequence, weakening or breaking the rolling flash cue that leads pilots down the approach centreline in low-visibility conditions.
Detection Method
Verify controller timing against the specified sequence rate, check each flasher head in firing order, and inspect the condenser discharge unit for capacitor swelling or leakage.
Precautions

Safety & Operational Notes

Series Circuit Isolation
Electrical Safety

Centreline bar, crossbar, and red side row circuits run on constant-current series loops that can carry several kV. De-energise and lock out the associated CCR, then verify zero energy at the tower base or barrette before opening any enclosure.

Sequenced Flasher Capacitor Discharge
Electrical Safety

Condenser discharge units driving the sequenced flashing lights on a CAT II configuration store a high-energy charge even after the master flasher controller is switched off; discharge each unit through its bleed resistor and confirm zero voltage before servicing a flasher head.

Elevated Tower & Off-Runway Access
Personnel Safety

Light bar towers extend along the extended centreline over terrain that may be uneven, waterlogged, or off the paved movement area; use fall protection when climbing frangible towers and assess ground conditions before positioning vehicles or ladders.

Frangibility Not to Be Defeated
Mechanical

Never substitute a frangible coupling or tower base with a rigid fitting, and do not over-torque connections during installation or repair; the structure must still break away cleanly on aircraft impact within the runway safety area.

Low-Visibility Work Coordination
Operational

CAT II operations depend on the full light pattern being available at reduced minima; obtain ATC/airside coordination and issue a NOTAM before any bar, crossbar, or flasher is taken out of service, and keep personnel and vehicles clear of the approach surface during aircraft operations.

FOD Control Along the Approach
Operational

Account for tools, fasteners, and hardware at every tower and barrette worked on, and remove or secure loose material before leaving the site, since debris in the approach area can be ingested or strike an aircraft on short final.

Insulation Test Before Re-Energisation
Electrical Safety

After any cable, connector, or transformer work on a bar, crossbar, or flasher circuit, megger test the affected series loop before restoring power, since a residual fault can trip the CCR or damage healthy fixtures on the same circuit.

Restore to Compliant State
Compliance

Do not leave the system with a bar out of aim tolerance, a dark flasher, or an out-of-sequence discharge pattern; verify photometric output and flasher timing against CAT II requirements before closing out the work and cancelling the associated NOTAM.

Field Insight

Engineering & Expert Notes

Verify Standby Transfer, Not Just Standby Existence
Reliability

CAT II operations depend on the backup power path actually completing a clean transfer within the required time, not merely on a standby generator being present and functional in isolation. Run live transfer tests under load on a defined schedule.

Side-Row Bars Must Be Assessed Relative to the Centreline
Photometric

A red side-row bar that individually meets its intensity minimum can still under-deliver the visual cue CAT II pilots rely on if it's noticeably dimmer than the adjacent centreline barrettes. Compare relative intensity, not just each fixture against its own spec.

Prioritise Alignment Surveys Near the Threshold
Structural

Fixtures closest to the runway threshold have the least angular tolerance for misalignment given the pilot's viewing geometry at 100ft decision height; weight inspection frequency toward that segment rather than treating the full array uniformly.

Isolate Side-Row Faults From Centreline Faults
Electrical

Verify the loop topology keeps a side-row bar fault from being able to also affect centreline barrette operation; a shared fault path undermines the distinct warning function the side-row bars are meant to provide.

Correlate SFL Faults With Weather Events
Troubleshooting

In fog- and snow-prone conditions typical of CAT II operations, moisture-related controller faults tend to cluster around specific weather events. Cross-reference fault logs with weather records to catch a developing ingress problem early.

Keep Survey Records Consistent Across Contractors
Compliance

CAT II category approval is tied to demonstrated system reliability and documented performance; inconsistent survey methodology or logging format between shifts or contractors can create audit gaps independent of the array's actual condition.

Quick Answers

Frequently Asked Questions

Short answers about CAT II approach lighting: minima, red side-row bars, decision bar, standards and maintenance.

Q1What is CAT II approach lighting?

It is a high-integrity precision approach lighting system for Category II operations. It builds on CAT I with extra centreline lights and barrettes, higher-intensity sequenced flashing lights, red side-row bars in the final approach segment and a decision bar.

Q2What operating minima does CAT II approach lighting support?

A decision height of 100 ft with RVR down to about 300 m (350 m in some regions, depending on local regulations). The added lighting concentrates visual information where the pilot needs it most, because there is less time and visual distance to confirm the runway environment than under CAT I.

Q3What are the red side-row bars?

Red lights on both sides of the approach path in the final 300 m segment. They mark the final segment distinctly from the earlier approach, warn of lateral deviation from the centreline and help define the approach corridor.

Q4What is the decision bar?

A row of lights at the decision height point that gives the pilot a visual reference for the go/no-go decision. It should illuminate correctly and at the specified intensity, and is checked semi-annually.

Q5How long is a CAT II system and how are the lights spaced?

The configuration is typically 731 m (2,400 ft) as standard, up to 914 m (3,000 ft) on shallow-slope sites, with barrettes (3 to 5 lights per bar) at 30 m (100 ft) intervals along the full length.

Q6How is CAT II different from CAT I?

CAT II adds red side-row bars in the final 300 m, a decision bar, extra centreline lights and barrettes, and sequenced flashing lights with higher intensity and a faster flash rate for fog. Its power design also adds independent circuits and duplicate isolating transformers per circuit sector to limit the effect of a single fault.

Q7How is CAT II approach lighting powered and controlled?

Independent CCR-fed series circuits serve the centreline barrettes, red side-row bars and the flasher array, with 5-step intensity control (2.8 A to 6.6 A) and possible automatic dimming based on RVR data. Flashers use dedicated capacitor-discharge units driving xenon strobes, and insulation resistance should be at least 50 MΩ.

Q8Which standards apply to CAT II approach lighting?

The main references are ICAO Annex 14 (configuration, spacing, colour and photometric requirements), FAA AC 150/5345-46 (CAT II components), IEC 61827 and FAA Engineering Brief #67 (LED CAT II component performance). Always verify the current edition and your aerodrome's approved requirements.

Q9How often should CAT II approach lighting be maintained?

Typical practice is quarterly lens cleaning, semi-annual sequenced flasher timing tests, decision bar function checks and automatic dimming and CCR step verification, and annual photometric intensity checks, seal and gasket inspection, insulation resistance tests and cable and connector inspection. Your airport's approved maintenance programme takes precedence.

Q10What are the common CAT II approach lighting problems?

Lens contamination in fog, rain, snow and de-icing chemicals, sequenced flasher synchronisation drift, misaligned elevated fixtures, red filter degradation from UV and thermal stress (colour fading toward orange), and CCR or power supply issues affecting brightness.

Go Further

Go Beyond the Component. Understand the Complete AGL System.

You have explored the component. Now understand how it works within the complete Airfield Ground Lighting system.

Learn AGL from fundamentals to design, installation, testing, photometry, commissioning, maintenance and troubleshooting through structured technical training at Precision AGL Academy.

Build practical knowledge. Understand the circuit. Read the standards. Troubleshoot with confidence.