Division 01 · PRV · Calendar / Interval Strategy

Preventive Maintenance

The routine, calendar-driven backbone of the handbook. Preventive maintenance is scheduled work performed regardless of condition — cleaning, tightening, alignment, and functional checks — carried out to prevent avoidable failure, detect deterioration early, and keep every AGL asset in reliable operating condition.

Philosophy: preventive maintenance is not simply "cleaning equipment." It addresses five asset conditions — electrical, mechanical, optical, environmental, and functional — and follows a fixed sequence from planning through to record and monitor, on every fixture, cable, connector, and control system in the system.

40
Topics in Division
04
Asset Groups (A–D)
05
Asset Conditions Assessed
10
Step PM Sequence

PM Philosophy

Every preventive-maintenance task in this division follows the same underlying sequence, regardless of asset type — and is judged against the same five conditions.

Plan
Isolate
Inspect
Clean
Adjust
Tighten
Test
Restore
Record
Monitor
Electrical condition Mechanical condition Optical condition Environmental condition Functional condition

PM Frequency

Exact frequency is set by the airport's approved maintenance programme, equipment requirements, and operational criticality. A typical planning structure looks like this.

FrequencyTypical PM Scope
Daily / ShiftOperational condition and obvious defects
WeeklyCleaning, visual condition, and minor checks
MonthlyFixture / equipment detailed PM
QuarterlyEquipment and circuit condition checks
Half-yearlyDetailed mechanical / electrical PM
AnnualComprehensive PM and condition assessment
Event-basedAfter failure, lightning, flooding, construction, severe weather, or major maintenance

Pre-Maintenance Requirements

Before any preventive-maintenance task begins, four requirement groups must be closed out.

Work Planning

  • Identify equipment/asset and location
  • Identify circuit
  • Review previous maintenance history and defects
  • Confirm task, tools, spares, PPE, and test instruments

Operational Coordination

  • Obtain required work authorization
  • Coordinate with ATC / airport operations where applicable
  • Coordinate airside access
  • Establish work limits and communication arrangements

Safety

  • Identify electrical, movement, and FOD hazards
  • Identify excavation / pit hazards where applicable
  • Apply isolation / LOTO requirements where required
  • Verify equipment is safe to work on

Documentation

  • Date, time, asset ID, circuit ID, location
  • Maintenance team and work order / reference
  • Previous condition
  • Maintenance activity and parts used

The 40 Topics

Grouped by asset type — click any topic to expand its maintenance activities and acceptance condition.

A

Runway Lighting

12 topics
MNT-PRV-001Runway Edge Light Preventive Maintenance
Maintenance Activities
  • Visually inspect fixture
  • Clean lens / prism
  • Remove dirt and contamination
  • Inspect housing
  • Check mounting and fasteners
  • Verify orientation and elevation
  • Inspect frangible arrangement
  • Inspect cable entry, secondary lead, connector
  • Check moisture ingress and corrosion
  • Check optical condition and illumination
  • Replace defective components
  • Restore fixture and record maintenance
Acceptance / Record

Acceptance: clean, secure, correctly oriented, free from unacceptable damage, properly connected, free from unacceptable moisture ingress, and operational.

MNT-PRV-002Runway Threshold Light Preventive Maintenance
Maintenance Activities
  • Clean optical surfaces
  • Inspect fixture housing
  • Inspect lens / prism and colour appearance
  • Verify orientation
  • Check mounting
  • Check cable and connector
  • Check moisture ingress
  • Check illumination
  • Inspect frangible components
  • Replace defective optical / electrical components
Acceptance / Record

Record: condition captured against the standard maintenance record on completion.

MNT-PRV-003Runway End Light Preventive Maintenance
Maintenance Activities
  • Fixture cleaning
  • Optical inspection
  • Housing inspection
  • Mounting inspection
  • Alignment verification
  • Connector inspection
  • Cable inspection
  • Moisture inspection
  • Functional check
  • Illumination verification
Acceptance / Record

Close-out: defect recording against the asset before sign-off.

MNT-PRV-004Runway Centreline Light Preventive Maintenance
Particular Attention
  • Fixture cleanliness
  • Optical condition
  • Fixture orientation
  • Mounting
  • Mechanical damage
  • Cable connection and connector condition
  • Moisture ingress
  • Illumination
  • Fixture identification
MNT-PRV-005Touchdown Zone Light Preventive Maintenance
Maintenance Activities
  • Clean optical components
  • Inspect fixture body
  • Verify fixture orientation
  • Inspect mounting
  • Check cable entry and connector
  • Check moisture ingress
  • Verify illumination
  • Check mechanical condition
  • Record defects
MNT-PRV-006Runway Guard Light Preventive Maintenance
Maintenance Activities
  • Fixture cleaning
  • Housing and lens inspection
  • Alignment verification
  • Mounting inspection
  • Cable and connector inspection
  • Functional operation check
  • Flashing operation check where applicable
  • Environmental-condition inspection
MNT-PRV-007Runway Fixture Cleaning
Cleaning Scope
  • Lens, prism, optical window
  • Housing and external surfaces
  • Mounting area
  • Base-can interface where applicable
Acceptance / Record

Removes: dust, mud, oil, dirt, organic contamination, and other deposits affecting optical performance — without damaging optical surfaces.

MNT-PRV-008Runway Fixture Alignment Verification
Verify
  • Correct orientation and directional alignment
  • Fixture position and elevation where applicable
  • Mechanical stability
  • Alignment relative to installation geometry
Acceptance / Record

Out of tolerance: corrective adjustment is performed and recorded.

MNT-PRV-009Runway Fixture Mounting Inspection
Check
  • Mounting bolts, nuts, washers
  • Base and frangible coupling
  • Mechanical stability and fixture seating
  • Foundation / interface condition
Acceptance / Record

Correct: any loose or damaged hardware found.

MNT-PRV-010Runway Fixture Fastener Tightening
Sequence
  • Confirm correct hardware
  • Inspect threads for corrosion / damage
  • Tighten using approved method
  • Apply specified torque where required
  • Avoid overtightening
  • Verify alignment after tightening
Acceptance / Record

Record: corrective action taken.

MNT-PRV-011Runway Optical-Component Cleaning
Scope
  • Lenses and prisms
  • Optical windows
  • Reflectors / optical surfaces where applicable
Acceptance / Record

Sequence: Clean → Inspect → Reassemble → Functional Check → Record.

MNT-PRV-012Runway Cable / Connector Inspection
Check
  • Cable condition and cable entry
  • Secondary lead
  • Connector body, locking, and sealing
  • Contact condition
  • Corrosion and moisture
  • Mechanical damage
Acceptance / Record

Deteriorated connectors: assessed for replacement or corrective maintenance.

B

Taxiway Lighting

8 topics
MNT-PRV-013Taxiway Edge Light Preventive Maintenance
Perform
  • Cleaning
  • Lens and housing inspection
  • Alignment verification
  • Mounting and fastener inspection
  • Cable and connector inspection
  • Moisture inspection
  • Functional check
MNT-PRV-014Taxiway Centreline Light Preventive Maintenance
Check
  • Optical cleanliness
  • Fixture condition
  • Alignment and mounting
  • Connector and cable
  • Moisture
  • Illumination and mechanical condition
MNT-PRV-015Taxiway Clearance Bar Maintenance
Perform
  • Fixture cleaning
  • Optical inspection
  • Mounting inspection
  • Alignment verification
  • Cable and connector inspection
  • Illumination verification
  • Functional testing
MNT-PRV-016Taxiway Exit Light Maintenance
Check
  • Fixture condition
  • Optical components
  • Alignment and mounting
  • Cable and connector
  • Illumination
  • Identification
MNT-PRV-017Rapid Exit Taxiway Light Maintenance
Particular Attention
  • Fixture alignment
  • Optical cleanliness
  • Mounting
  • Cable / connector condition
  • Mechanical stability
  • Illumination
  • Environmental contamination
MNT-PRV-018Taxiway Fixture Cleaning
Scope
  • Lens and prism
  • Housing
  • External surfaces
  • Surrounding fixture area
Acceptance / Record

Care: cleaning must not compromise seals or optical components.

MNT-PRV-019Taxiway Alignment Verification
Verify
  • Orientation and position
  • Height
  • Stability
  • Correct installation geometry
MNT-PRV-020Taxiway Mounting Inspection
Inspect
  • Mounting hardware and base
  • Frangible components
  • Mechanical stability
  • Corrosion
  • Foundation / interface
C

Other AGL Equipment

12 topics
MNT-PRV-021PAPI / APAPI Preventive Maintenance
Maintenance Activities
  • Clean optical windows
  • Inspect housing, mounting, foundation
  • Verify azimuth alignment
  • Verify elevation setting and beam setting
  • Inspect cable entry and connector
  • Check environmental condition
  • Verify illumination and identification
  • Verify calibration status where applicable
Acceptance / Record

Record: results against the asset once verified.

MNT-PRV-022Airfield Sign Preventive Maintenance
Perform
  • Face and housing cleaning
  • Message / identification verification
  • LED / module and driver inspection
  • Internal wiring inspection
  • Cable and connector inspection
  • Mounting and foundation inspection
  • Water-ingress inspection
  • Illumination and colour / visibility verification
MNT-PRV-023CCR Preventive Maintenance
External
  • Clean cabinet
  • Check labels and ventilation openings
  • Inspect cooling arrangement and fans
  • Inspect doors and locks
MNT-PRV-024Isolation Transformer Preventive Maintenance
Inspect
  • Nameplate and rating
  • Housing and sealing
  • Cable leads and connector
  • Primary / secondary connection
  • Mechanical condition, corrosion, moisture
  • Pit condition and position / mounting
Acceptance / Record

Record: any deterioration identified.

MNT-PRV-025Primary Cable Preventive Maintenance
Focus Areas
  • Cable route, identification, markers
  • Accessible termination points
  • Cable-joint condition
  • Signs of damage or water entry
  • Duct / trench condition
  • Cable sealing and separation / protection
Acceptance / Record

Testing: where required, follow the approved test procedure separately.

MNT-PRV-026Connector Preventive Maintenance
Check
  • Plug and receptacle
  • Contacts and locking mechanism
  • Sealing and crimp
  • Cable lead
  • Corrosion and heating
  • Moisture and identification
MNT-PRV-027Earthing-System Preventive Maintenance
Inspect
  • Earth electrode and pit
  • Earth conductor and bonding conductors
  • Equipment / base-can / transformer bonding
  • CCR and sign earth
  • Earth continuity
  • Lightning-protection connections and SPD condition
Acceptance / Record

Testing: electrical testing follows the applicable approved procedure.

MNT-PRV-028ALCMS Preventive Maintenance
Check
  • HMI, displays, commands, feedback
  • Alarms and event logs
  • Communication and PLC / interface
  • Network equipment and remote status
  • Control cabinets
  • System time / date and data logging
Acceptance / Record

Verify: commands result in the expected system response.

MNT-PRV-029Approach Lighting Preventive Maintenance
Perform
  • Fixture cleaning
  • Alignment verification
  • Structure, pole, crossbar inspection
  • Foundation inspection
  • Cable and transformer inspection
  • Connector inspection
  • Colour / illumination verification
  • Corrosion inspection and vegetation clearance
MNT-PRV-030Stop Bar Preventive Maintenance
Check
  • Fixture condition and alignment
  • Illumination
  • Mounting and cable entry
  • Connector
  • Optical cleanliness
  • Functional operation
MNT-PRV-031Runway Guard Light Preventive Maintenance (Circuit-Level)
Perform
  • Cleaning and alignment
  • Mounting check
  • Cable and connector check
  • Flashing operation check where applicable
  • Illumination check
  • Environmental and mechanical inspection
Acceptance / Record

Note: complements Topic 06 with the circuit / equipment-level checks under Group C.

MNT-PRV-032Base-Can Preventive Maintenance
Check
  • Base-can condition and level
  • Alignment and foundation
  • Grouting and drainage
  • Cover and bolts
  • Frangible coupling and cable entry
  • Pavement interface, water accumulation, corrosion
D

Routine Maintenance Activities

8 topics
MNT-PRV-033Cleaning
Applies To
  • Fixtures, lenses, prisms
  • Signs
  • PAPI optical windows
  • CCR cabinets
  • Equipment enclosures
  • Accessible pits and relevant surfaces
MNT-PRV-034Tightening
Applies To
  • Fixture fasteners and mounting bolts
  • Connector locking arrangements
  • Equipment mounting
  • Accessible terminals
  • Structural fasteners
Acceptance / Record

Standard: use approved torque requirements where specified.

MNT-PRV-035Alignment
Verify
  • Fixture orientation, position, elevation
  • PAPI alignment
  • Approach-light alignment
  • Sign orientation
  • Other alignment-critical equipment
MNT-PRV-036Functional Checking
May Include
  • Light ON/OFF and intensity-step operation
  • Flashing operation where applicable
  • Sign illumination and PAPI operation
  • CCR operation and ALCMS commands
  • Alarm operation
  • Remote control and equipment feedback
MNT-PRV-037Visual Inspection
Should Identify
  • Damage, corrosion, cracks
  • Loose components
  • Water ingress and contamination
  • Missing hardware
  • Cable damage and connector deterioration
  • Structural and environmental deterioration
MNT-PRV-038Lubrication Where Applicable
Performed Only Where
  • Manufacturer permits it
  • Component requires lubrication
  • Correct lubricant is specified
  • Won't contaminate optical / electrical components
Acceptance / Record

Never apply lubricant indiscriminately to AGL equipment.

MNT-PRV-039Component Condition Assessment
Classification
  • Critical
  • Major
  • Minor
  • Observation
Acceptance / Record

Use: the airport's approved defect/condition classification consistently across every asset.

MNT-PRV-040Maintenance Record Completion
Record Should Include
  • Asset ID, equipment type, location, circuit
  • Date, frequency, technician, supervisor
  • Initial and final condition
  • Work performed and parts replaced
  • Test / functional result
  • Defects found and classification
  • Corrective action and photographic evidence
  • Next PM due date, remarks, sign-off

Defect Handling During PM

When a defect is discovered mid-task, the same seven-step handling sequence applies across every topic in this division.

1
Identify

Determine the exact asset and defect.

2
Classify

Critical / Major / Minor / Observation.

3
Assess Impact

Safety, availability, function, photometry, mechanical or electrical integrity.

4
Correct

Repair or replace where authorized.

5
Verify

Confirm restoration.

6
Record

Update the maintenance record.

7
Escalate

Unresolved significant defects enter the corrective-maintenance process.

Frequently Asked Questions

Quick answers about preventive maintenance of AGL systems, based on the topics in this division.

12 QUESTIONS
Q1What is preventive maintenance in Airfield Ground Lighting (AGL)?

Preventive maintenance is scheduled, calendar-driven work performed regardless of asset condition. It covers cleaning, tightening, alignment and functional checks, and is carried out to prevent avoidable failure, detect deterioration early and keep every AGL asset in reliable operating condition.

Q2What does Division 01 of the AGL Maintenance Handbook cover?

Division 01 contains 40 preventive-maintenance topics in four asset groups: Group A Runway Lighting (12 topics), Group B Taxiway Lighting (8 topics), Group C Other AGL Equipment (12 topics) and Group D Routine Maintenance Activities (8 topics). Group C includes PAPI / APAPI, airfield signs, CCRs, isolation transformers, primary cable, connectors, earthing, ALCMS, approach lighting, stop bars and base-cans.

Q3Is AGL preventive maintenance just cleaning the fixtures?

No. Preventive maintenance is not simply cleaning equipment. Each task is judged against five asset conditions: electrical, mechanical, optical, environmental and functional. It is applied to every fixture, cable, connector and control system in the AGL system.

Q4What is the standard sequence for an AGL preventive-maintenance task?

Every task follows the same ten-step sequence regardless of asset type: Plan, Isolate, Inspect, Clean, Adjust, Tighten, Test, Restore, Record and Monitor.

Q5How often should AGL preventive maintenance be performed?

The exact frequency is set by the airport's approved maintenance programme, the equipment requirements and operational criticality. A typical planning structure is daily or shift checks for operational condition and obvious defects, weekly cleaning and visual checks, monthly detailed fixture PM, quarterly circuit and equipment condition checks, half-yearly detailed mechanical and electrical PM, and an annual comprehensive PM and condition assessment. Event-based PM is also carried out after failure, lightning, flooding, construction, severe weather or major maintenance.

Q6What must be completed before starting AGL preventive maintenance?

Four requirement groups must be closed out first. Work planning covers identifying the asset, location and circuit, reviewing maintenance history, and confirming tools, spares, PPE and test instruments. Operational coordination covers work authorization, ATC or airport operations coordination, airside access, work limits and communications. Safety covers electrical, movement, FOD and pit hazards, plus isolation or LOTO where required. Documentation covers the date, time, asset ID, circuit ID, location, team, work order reference and previous condition.

Q7What does preventive maintenance of a runway edge light include?

It includes visually inspecting the fixture, cleaning the lens or prism, removing dirt and contamination, inspecting the housing, checking mounting and fasteners, verifying orientation and elevation, inspecting the frangible arrangement, checking the cable entry, secondary lead and connector, checking for moisture ingress and corrosion, checking optical condition and illumination, replacing defective components, and restoring the fixture and recording the work. The fixture is accepted when it is clean, secure, correctly oriented, free from unacceptable damage, properly connected, free from unacceptable moisture ingress and operational.

Q8Can lubricant be applied to AGL equipment during preventive maintenance?

Only where the manufacturer permits it, the component requires lubrication, the correct lubricant is specified and it will not contaminate optical or electrical components. Lubricant must never be applied indiscriminately to AGL equipment.

Q9How should fasteners be tightened during AGL preventive maintenance?

Confirm the correct hardware, inspect threads for corrosion or damage, tighten using the approved method, apply the specified torque where required, avoid overtightening and verify alignment after tightening. Any corrective action taken is recorded.

Q10How are defects found during preventive maintenance handled?

A seven-step sequence applies across every topic: identify the asset and defect, classify it as Critical, Major, Minor or Observation, assess the impact on safety, availability, function, photometry and mechanical or electrical integrity, correct it by repair or replacement where authorized, verify restoration, update the maintenance record, and escalate. Unresolved significant defects enter the corrective-maintenance process.

Q11What should an AGL preventive-maintenance record include?

The record should include the asset ID, equipment type, location and circuit; date, frequency, technician and supervisor; initial and final condition; work performed and parts replaced; test or functional result; defects found and their classification; corrective action and photographic evidence; and the next PM due date, remarks and sign-off.

Q12When does preventive maintenance lead to testing or corrective maintenance?

Preventive maintenance is mainly inspection, cleaning, tightening, alignment and functional checking. Where electrical testing is required, for example on primary cable or the earthing system, it follows the applicable approved test procedure separately. Deteriorated components, such as connectors, are assessed for replacement or corrective maintenance, and unresolved significant defects are escalated to the corrective-maintenance process.

Go Further

Don't Just Maintain the AGL System. Understand It.

Preventive maintenance is more than scheduled cleaning and inspection.

Build the technical knowledge to understand how AGL assets behave, what conditions cause deterioration, how maintenance activities affect system performance, and when inspection must lead to testing, troubleshooting or corrective action.

Maintain with purpose. Understand the system. Build technical capability.

Build Practical AGL Maintenance Capability
AGL Fundamentals Components Electrical Systems Preventive Maintenance Inspection Testing Photometry Troubleshooting Commissioning

Talk to Precision AGL Academy

Follow the Academy