How is the secondary cable routed?

A short, low-voltage run from the isolation transformer to the light. It is protected in a sleeve, kept apart from the primary loop, and joined by plug-in connectors with slack so the fixture can be removed.

ELEVATED LIGHT OR SIGNtransformer in a can beside the fixture FRANGIBLE COUPLING XFMR PRIMARY LOOP (LONG RUN) SLEEVE / CONDUIT SECONDARY CABLE (SHORT) 1 2 3 4 5 INSET LIGHTtransformer in the base can below the fixture XFMR PRIMARY LOOP SECONDARY LEADstays inside the base can CONNECTOR AT EACH END 1 3
secondary cable (short)
primary loop (long run)
can, sleeve, conduit
plug-in connector
The Fact Installation practice

The secondary cable is the last short link in the circuit. It runs from the isolation transformer’s secondary terminals to the lamp or LED load in the fixture, and it is electrically isolated from the primary series loop. Because it carries the lamp load at low voltage, it is kept as short as practical; the long run is the primary cable.

For an elevated light or a sign, it leaves the can through a short sleeve or conduit, rises through the base and frangible coupling and reaches the fitting. For an inset light it normally stays inside the base can and rises straight to the fixture. Plug-in connectors at each end and a slack loop let the fixture or transformer be removed without disturbing the loop. Keep it clear of the primary cable, record connector and cable details on the as-built drawings, and treat the circuit as live until it has been isolated and made safe.

1 · From the Transformer
The secondary cable leaves the transformer’s secondary terminals through a plug-in connector.
2 · Sleeve or Conduit
Where it leaves the can and runs to the fixture, it is protected in a sleeve or conduit, apart from the primary cable.
3 · Connector at the Fixture
A plug-in connector at the fixture lets the light be removed and replaced without cutting the cable.
4 · Entry to the Fitting
Up through the base and frangible coupling of an elevated light, or straight up into an inset fixture.
5 · Short, with Slack
As short as practical to limit voltage drop, with a slack loop so the fixture or transformer can be lifted out.
FunctionFeeds the lamp or LED load from the transformer secondary
LengthAs short as practical
ConnectionsPlug-in connectors at both ends
ReferenceFAA AC 150/5345-7 · AC 150/5340-30 · ICAO Doc 9157 Part 5
Diagrams are schematic cross-sections and not to scale; moving dots show a reference direction only, because the current is alternating. Secondary cable type, maximum length, sleeve arrangement and connector type vary by transformer, fixture and manufacturer; follow the design drawings and the manufacturer’s data.
Entry 25 · Primary cable routing Entry 27 · Connector locations

Frequently Asked Questions

Q1What is the secondary cable in an AGL circuit?

The secondary cable is the short, low-voltage cable that runs from the isolation transformer’s secondary terminals to the lamp or LED load in the fixture. It is electrically isolated from the primary series loop, which is the long run.

Q2Why is the secondary cable kept short?

It carries the lamp load at low voltage, so every extra metre adds voltage drop and wasted power. It is kept as short as practical, and the maximum length is set by the transformer and fixture data.

Q3How is the secondary cable routed to an elevated light or sign?

From the can beside the fixture it goes through a short sleeve or conduit to the base, then up through the frangible coupling to the fitting. Plug-in connectors at each end, and slack, let the fixture be removed without disturbing the loop.

Q4How is it routed to an inset light?

Directly up from the transformer in the base can to the fixture, usually staying inside the can, with a connector at each end and enough slack to lift the fixture out.

Q5Is it safe to work on the secondary side of a live circuit?

Treat the circuit as live until it has been isolated and made safe under site procedures. An energised series transformer with an open secondary can present a hazardous voltage, so never open or disconnect the secondary on a live loop, and clear any open secondary found in service, such as a failed lamp, promptly.

Precision AGL Academy

See It. Understand It. Then Learn How to Engineer It.

Recognising an AGL system visually is the first step. The next step is knowing how to design, install, test, commission and maintain them correctly.

Build Practical AGL Engineering Skills

Go deeper with structured training from Precision AGL Academy, covering:

AGL Fundamentals Design & Electrical Engineering Approach Lighting Photometry Installation & Commissioning Maintenance & Troubleshooting

Learn how each light, sign and circuit works as part of a complete airport lighting system, not just as an isolated diagram.

See. Understand. Apply. Engineer.