The final gate of the entire AGL commissioning process. Division 23 does not generate new field evidence — it converts the technical evidence produced across Divisions 01–22 into a formal handover and project-closure decision: the installed system, test evidence, photometric results, documentation, assets, spares, training, regulatory requirements and outstanding actions are reviewed, and the system is either accepted, conditionally accepted, or held pending closure.
Philosophy: final acceptance is not based on a single successful test. It is based on demonstrated completion of the installation, successful testing and performance verification, closure of deficiencies, completion of documentation, verification of assets and spares, completion of training, satisfaction of applicable regulatory requirements, and formal acceptance by the authorized parties.
Every topic in this division follows the same underlying sequence, whatever the evidence being reviewed — and is checked against the same four acceptance domains before the project is signed off.
Division 23 runs as a staged gate rather than a single pass — each stage below builds on the one before it, and the division closes only once every stage is signed off.
| Stage | What It Confirms |
|---|---|
| Physical & Test Review | Final installation, testing, and photometric evidence generated across Divisions 01–22 are complete and accepted |
| Deficiency Closure | Outstanding punch-list and snag items are closed or formally dispositioned |
| Documentation Review | Test reports, calibration records, as-built drawings, and O&M documentation are complete and correspond to the actual installation |
| Assets & Spares | The asset register is verified and project-supplied spare parts are formally handed over |
| People Readiness | Required operator/maintenance training and client witness points are complete |
| Compliance & Final Testing | Applicable regulatory requirements are satisfied and final acceptance testing is completed |
| Operational Acceptance | A formal decision is made on readiness for operational use |
| Handover Package | The handover package, certificate, and final commissioning report are compiled and issued |
| Closure | Every technical and administrative condition is satisfied and the project is formally closed |
Two requirement groups should be closed out before the division-23 team starts working through the topic list.
Grouped by acceptance focus, in the order the gate is normally worked — click any topic to expand its verification checks and acceptance criteria.
Acceptance Criteria: the final installation matches the approved design, approved changes, and actual as-built condition, with no unresolved safety condition.
Acceptance Criteria: every applicable commissioning test across Divisions 01–22 is reported, accepted, and closed, with no open retest.
Acceptance Criteria: measured photometric results are checked against the applicable requirement for every location, with full compliance or formally dispositioned exceptions.
Hold Point: no critical operational or safety-related punch-list item remains open without a formally approved disposition.
Acceptance Criteria: every remaining snag is classified, and any item not fully closed carries a documented disposition and owner.
Acceptance Criteria: test reports are complete, correctly referenced, and verified to correspond to the actual installed equipment and final configuration.
Hold Point: calibration status must be shown valid at the time each relevant measurement was performed — any gap is investigated before final acceptance.
Acceptance Criteria: final drawings represent the actual commissioned installation, confirmed by drawing-to-field and field-to-drawing verification.
Acceptance Criteria: O&M documentation is complete and reflects the actual installed equipment and configuration.
Acceptance Criteria: every commissioned asset is correctly and completely entered in the asset register, cross-checked against the equipment schedule.
Acceptance Criteria: project-supplied spare parts are verified against the register and formally handed over with storage and replacement instructions.
Acceptance Criteria: required operator and maintenance training is complete, with attendance, material, and competency assessment on record.
Acceptance Criteria: all contractually required client/consultant witness points are completed or formally dispositioned, with signed records.
Hold Point: applicable regulatory/authority requirements are confirmed satisfied, using only the requirements relevant to this specific airport/project.
Acceptance Criteria: final acceptance tests confirm the system performs correctly in its final installed, configured, and documented condition.
Acceptance Criteria: the system is formally declared Ready for Operation, Not Ready for Operation, or Conditionally Accepted, with any conditions formally documented.
Acceptance Criteria: the handover package is compiled per the recommended structure, with every section populated and cross-referenced.
Acceptance Criteria: the handover certificate is completed, signed, and correctly records scope, status, and any outstanding conditions per the contract terminology.
Acceptance Criteria: the final consolidated commissioning report is complete per the recommended structure and formally approved.
Acceptance Criteria: every technical and administrative closure condition is satisfied, the handover is complete, and the final dossier is formally archived — closing Division 23 and the project.
When final review finds a gap or deviation mid-check, the same sequence applies across every topic in this division.
Determine exactly what evidence, document, or condition is missing or non-conforming.
Safety/operational-critical, contractual/regulatory, or administrative/minor.
Does it block operational acceptance and handover, or can it be tracked as a residual condition?
Add to the punch-list, snag-list, or NCR register with owner and target date.
Rectify, retest, or complete the missing documentation or action.
Confirm closure against the same acceptance criteria.
Update the master review tables, punch-list, and handover certificate before sign-off.
Unresolved safety-critical or regulatory items withhold final operational acceptance and handover certification.
Quick answers about Division 23 — Handover & Final Acceptance in the AGL Testing & Commissioning Manual.
Division 23 of the AGL Testing & Commissioning Manual covers Handover & Final Acceptance. The final gate of the entire AGL commissioning process. Division 23 does not generate new field evidence — it converts the technical evidence produced across Divisions 01–22 into a formal handover and project-closure decision: the installed system, test evidence, photometric results, documentation, assets, spares, training, regulatory requirements and outstanding actions are reviewed, and the system is either accepted, conditionally accepted, or held pending closure. It contains 20 topics (TC-HFA-001 to TC-HFA-020) organised into 9 groups (A–I), each topic with its own verification checks.
Final acceptance is not based on a single successful test. It is based on demonstrated completion of the installation, successful testing and performance verification, closure of deficiencies, completion of documentation, verification of assets and spares, completion of training, satisfaction of applicable regulatory requirements, and formal acceptance by the authorized parties.
Every topic in this division follows the same underlying sequence, whatever the evidence being reviewed — and is checked against the same four acceptance domains before the project is signed off. Steps: Compile Evidence → Review Against Requirement → Identify Gap or Deviation → Close or Disposition → Re-Verify → Record & Sign Off. Focus areas: Installation & test completeness; Documentation & asset readiness; People & compliance readiness; Formal acceptance & closure.
Division 23 has 20 topics in 9 groups. A — Physical & Test Review: Final Installation Inspection, Final Testing Review, Final Photometry Review. B — Deficiency Closure: Outstanding Punch-List Review, Outstanding Snag Review. C — Documentation Review: Test-Report Review, Calibration-Document Review, As-Built Drawing Review, O&M-Document Review. D — Assets & Spares: Asset-Register Verification, Spare-Parts Handover. E — People Readiness: Training Completion Verification, Client Witness Completion. F — Compliance & Final Testing: Regulatory Verification, Final Acceptance Testing. G — Operational Acceptance: Final Operational Acceptance. H — Handover Package: Handover Package Preparation, Handover Certificate, Final Commissioning Report. I — Closure: Project Closure.
Division 23 runs as a staged gate rather than a single pass — each stage below builds on the one before it, and the division closes only once every stage is signed off. Physical & Test Review: Final installation, testing, and photometric evidence generated across Divisions 01–22 are complete and accepted; Deficiency Closure: Outstanding punch-list and snag items are closed or formally dispositioned; Documentation Review: Test reports, calibration records, as-built drawings, and O&M documentation are complete and correspond to the actual installation; Assets & Spares: The asset register is verified and project-supplied spare parts are formally handed over; People Readiness: Required operator/maintenance training and client witness points are complete; Compliance & Final Testing: Applicable regulatory requirements are satisfied and final acceptance testing is completed; Operational Acceptance: A formal decision is made on readiness for operational use; Handover Package: The handover package, certificate, and final commissioning report are compiled and issued; Closure: Every technical and administrative condition is satisfied and the project is formally closed.
Two requirement groups should be closed out before the division-23 team starts working through the topic list. Evidence Package: Complete Division 01–22 test reports, results, and calibration references; Approved as-built drawings and equipment/cable schedules; O&M manuals, asset register, and spare-parts documentation; Training records, attendance registers, and competency assessments; Applicable regulatory/authority requirements for this specific project. Review Team & Access: Confirm client, consultant, and airport-authority representation is available for witnessing; Confirm access to the completed installation for the final physical inspection; Confirm outstanding NCRs and corrective actions from earlier divisions are visible to the review team; Do not begin formal final acceptance review until Divisions 01–22 evidence is substantially complete.
When final review finds a gap or deviation mid-check, the same sequence applies across every topic in this division. (1) Identify — Determine exactly what evidence, document, or condition is missing or non-conforming; (2) Classify — Safety/operational-critical, contractual/regulatory, or administrative/minor; (3) Assess Impact — Does it block operational acceptance and handover, or can it be tracked as a residual condition?; (4) Log — Add to the punch-list, snag-list, or NCR register with owner and target date; (5) Correct — Rectify, retest, or complete the missing documentation or action; (6) Re-Verify — Confirm closure against the same acceptance criteria; (7) Record — Update the master review tables, punch-list, and handover certificate before sign-off; (8) Escalate — Unresolved safety-critical or regulatory items withhold final operational acceptance and handover certification.
Handover and final acceptance is where commissioning responsibility formally transfers to the operator.
Build the technical knowledge to understand acceptance criteria, outstanding-item management, and how a properly structured handover protects both the contractor and the operator long after the project closes.
Hand over with precision. Accept with confidence. Operate with certainty.
Please read before relying on any content on this page or on any record downloaded from it.