The CCR failure modes

A CCR can fail inside the unit, but many apparent CCR faults begin on the supply or in the series circuit. Knowing the pattern saves time.

CCR FAILURE MODES WHERE A CCR PROBLEM CAN START SUPPLY Loss, out of range CCR UNIT Control, power, cooling OUTPUT Open, overcurrent CIRCUIT Open, earth fault INSIDE THE CCR Control board, power stage, fans RESULT No light or wrong output OUTSIDE THE CCR Series circuit and cabling
supply / outside
inside the CCR
output / result
circuit fault
The Fact Failure modes

1Supply side

Loss of supply, a tripped breaker, a missing phase or a supply outside tolerance all stop or disturb the output. These are the first things to rule out, because they are quick to check.

2Inside the CCR

Control board faults, damage to the power stage (including surge damage), a failed contactor, blocked filters or cooling failure and ageing components can stop regulation or cause a trip. Heat and dust are common underlying causes.

3The circuit it feeds

An open circuit or an earth fault in the series loop is often reported by the CCR but caused outside it. Water ingress at connectors and joints, damaged cable and failed isolating transformers are common causes. Isolate the CCR and check the circuit with continuity and insulation tests before replacing the CCR.

ElementDetail
Loss of supplyNo output; check breaker, supply and phases
Supply out of rangeWarning or trip; check supply voltage
Control board faultWrong step, no response or unexpected trip
Power stage or contactor faultOutput unstable or absent
OverheatingWarning then trip; check fans, filters, ventilation
Open or earth fault in circuitTrip or alarm; test the circuit, not just the CCR
ReferenceICAO Annex 14 Vol I Ch 10 · FAA AC 150/5340-26 · IEC 61822 · FAA AC 150/5345-10
Teaching diagram: Failure patterns vary with CCR technology and age. Use the manufacturer guidance and site records. Isolate, lock out and prove dead before opening the cabinet. Never open or touch an energised series circuit. Once it is isolated and proved dead, earth it as the site procedure requires before working on it: a series circuit can carry lethal voltage even at low current.
Entry 26 · CCR fault indication Entry 28 · Surge protection devices for CCR and circuits

Frequently Asked Questions

Q1What fails most often on a CCR?

It depends on the model and environment. Heat, dust and ageing components are common underlying causes, and supply problems are common triggers.

Q2How do I tell a CCR fault from a circuit fault?

Isolate the CCR and test the circuit. If the circuit tests clean and the CCR still misbehaves into a known good load, the CCR is the suspect.

Q3Why does cooling matter?

Heat shortens component life and can trigger over-temperature trips. Keep fans, filters and ventilation clean and working.

Q4Does a single CCR failure put the whole airfield in the dark?

Only the circuits it feeds are affected. A standby CCR, and interleaving lamps across two circuits where the design allows, reduces the impact.

Precision AGL Academy

See It. Understand It. Then Learn How to Engineer It.

Recognising an AGL system visually is the first step. The next step is knowing how to design, install, test, commission and maintain them correctly.

Build Practical AGL Engineering Skills

Go deeper with structured training from Precision AGL Academy, covering:

AGL Fundamentals Design & Electrical Engineering Approach Lighting Photometry Installation & Commissioning Maintenance & Troubleshooting

Learn how each light, sign and circuit works as part of a complete airport lighting system, not just as an isolated diagram.

See. Understand. Apply. Engineer.