Flasher Control Unit

The intelligent controller that orchestrates the precise timing and sequencing of Sequenced Flashing Lights (SFL) in approach lighting systems. This unit generates the precisely timed trigger signals that create the "rolling" or "chasing" effect, providing pilots with dynamic directional cues during final approach, particularly in low‑visibility conditions.

Flasher control unit sequencing approach lighting sequenced flashing lights

Image disclaimer: For identification and illustration only. It may show a product by another manufacturer and may not depict the exact item described; it is not a statement of any product’s quality, approval or performance. Third-party image and trademark rights belong to their owners. See full notice.

Overview

What Is It?

A Flasher Control Unit (also known as an SFL Controller or Sequence Controller) is an electronic device that generates and manages the precisely timed trigger signals for Sequenced Flashing Lights (SFL) in approach lighting systems. It is the "brain" behind the dynamic "rolling" or "chasing" effect that provides pilots with directional cues during final approach. The unit receives input from the Airfield Lighting Control and Monitoring System (ALCMS) or manual controls, and outputs synchronised trigger pulses to each SFL unit along the approach path, ensuring a seamless and consistent flash sequence from the outer end toward the runway threshold. The Flasher Control Unit is a critical component of precision (ALSF‑1/2) and medium‑intensity (MALSF/MALSR) approach lighting systems.

Modern Flasher Control Units use microprocessor‑based technology with high‑precision timing crystals, offering exceptional accuracy and stability. They often include self‑diagnostic features, remote monitoring capabilities, and redundancy options to ensure continuous operation in critical low‑visibility conditions.

Purpose

Purpose & Function

The flasher control unit's purpose is to turn the SFL system's rolling flash pattern from a set of individually flashing lights into a single, coherent directional cue a pilot can read at a glance — determining not just when each light flashes but the precise delay between each one that creates the visual impression of motion toward the runway threshold. Because that impression depends entirely on consistent, repeatable timing, the unit's precision timing source and stored sequence are what let the system reproduce the same rolling effect flash after flash, night after night, regardless of ageing or environmental conditions. Without accurate sequencing at this level, the SFL system would degrade from a clear, unmistakable directional signal into a scattered pattern of separately flashing lights carrying far less useful information to the pilot.

Application

Where Is It Used?

Flasher Control Units are deployed as part of approach lighting systems that require sequenced flashing guidance. They are used in:

  • ALSF‑1 and ALSF‑2 systems – controlling SFL for CAT I, II, and III precision approaches.
  • MALSF and MALSR systems – managing SFL for medium‑intensity approach lighting.
  • Calvert II systems – providing SFL control for British approach lighting configurations.
  • Runways with low‑visibility operations (RVR below 800 m) – where precise SFL timing is essential for pilot guidance.
  • Major international airports – with CAT II/III capability requiring reliable SFL control.
  • Military airbases – requiring all‑weather approach capability with SFL guidance.
  • Airfields with remote monitoring – where the Flasher Control Unit integrates with ALCMS for centralised control.
Placement

Installation & Location

The flasher control unit is rack- or panel-mounted inside the equipment shelter or CCR room serving the approach lighting system, positioned close to the flasher power supply and synchronization unit it works alongside so control wiring between them stays short. It is wired into the sequenced flashing light circuit and, where fitted, into the ALCMS network for remote monitoring and control, with its own protective circuit breaker in the shelter's distribution board. The unit's location within the equipment room is chosen for technician access to its status indicators and test points, and for straightforward tracing of the control cabling out to the SFL units on the approach lighting structures.

Function

How Does It Work?

The Flasher Control Unit operates through a combination of precision timing, signal generation, and system integration:

  • Timing Generation: The unit uses a high‑precision crystal oscillator or GPS‑synchronised clock to generate the master timing reference. This ensures that all SFL units flash with consistent timing, regardless of environmental conditions or equipment ageing.
  • Sequence Programming: The unit is programmed with the required flash sequence, including the number of SFL units, the delay between each unit (typically 50–200 ms), and the overall flash rate (typically 60–120 flashes per minute). The sequence is stored in non‑volatile memory.
  • Trigger Outputs: The unit outputs individual trigger pulses to each SFL unit via dedicated control circuits. These pulses cause the SFL units to flash in the required order, creating the "rolling" effect toward the threshold.
  • Intensity Control Interface: The unit interfaces with the CCR or intensity control system, adjusting the flash intensity (brightness) based on ATC commands or automatic RVR‑based dimming.
  • ALCMS Integration: Modern Flasher Control Units communicate with the ALCMS via serial, Ethernet, or fibre optic links, allowing remote monitoring, control, and configuration. This enables ATC to adjust flash rates and sequences from the control tower.
  • Self‑Diagnostics: The unit continuously monitors its own operation and the status of connected SFL units. It can detect faults such as missing trigger signals, incorrect timing, or communication errors, and report them to the ALCMS.
  • Redundancy: Critical installations often use dual Flasher Control Units with automatic failover, ensuring continuous SFL operation in the event of a primary unit failure.
Architecture

System Architecture & Control Logic

The Flasher Control Unit sits in the middle of the SFL control chain, translating a single high-level command into the individually timed triggers each Sequenced Flashing Light needs. At the top, the ALCMS issues the operating command — flash rate, on/off, and RVR-linked intensity step — either automatically or from ATC in the tower. Where multiple Flasher Control Units must fire in step across a large approach lighting array or between adjacent systems, a Flasher Synchronization Unit distributes a common master clock that the control unit locks its sequence to. The control unit itself holds the stored delay sequence between SFL positions (typically 50–200 ms per step) and issues one trigger output per SFL, in order, to create the rolling effect toward the threshold; it does not generate the flash energy itself, only the timing command, which each Flasher Power Supply converts into a high-current discharge pulse for its SFL. Status — missing triggers, timing drift, communication loss — flows back up to the ALCMS, and in redundant installations a standby control unit takes over automatically if the primary drops out mid-sequence.

ALCMS / Sync Unit → Flasher Control Unit → Flasher Power Supply(s) → SFL (with status feedback)

ALCMS / ATC COMMAND Flash rate, on/off, RVR-linked intensity FLASHER SYNCHRONIZATION UNIT Distributes master clock (optional, multi-unit sites) FLASHER CONTROL UNIT Stores sequence, outputs per-SFL timed triggers FLASHER POWER SUPPLY (PER SFL / GROUP) Converts trigger into a high-current flash pulse SEQUENCED FLASHING LIGHT (SFL) Fires in order, creating the rolling effect SEQUENCE, NOT ENERGY Control unit sets timing; power supplies do the work Standby unit fails over automatically if fitted STATUS FEEDBACK Missing triggers, timing drift, comms loss reported to ALCMS
Visual Overview

Sequenced Trigger: Creating the Rolling Effect

Timing Reference

Crystal oscillator or GPS-synchronised clock

ALCMS / Manual Control

Sets flash rate & sequence from the tower

Flasher Control Unit

Stores the sequence, outputs individually timed triggers

SFL 1
Outer
+150ms →
SFL 2
+150ms →
SFL 3
+150ms →
SFL 4
+150ms →
SFL 5
Threshold
Construction

Physical Construction

The Flasher Control Unit is typically housed in a 19-inch rack-mount chassis or a wall-mounted enclosure for installation within the equipment room alongside the CCRs and flasher power supplies it coordinates. A microprocessor-based control board with a high-precision timing crystal or oscillator occupies the core of the unit, with isolated output drivers or relay stages for each SFL trigger channel mounted on the same or an adjacent board. The front panel carries status LEDs for each channel, fault indicators, and on advanced units a small display or touchscreen for configuration and diagnostics. Rear or base-mounted terminal blocks and connectors handle the incoming ALCMS/manual control interface and the outgoing trigger wiring to each Flasher Power Supply, with surge protection fitted to the trigger outputs given their exposure to lightning-induced transients on the field wiring. Redundant units may duplicate the controller board within the same chassis with automatic failover circuitry.

Specification

Technical Parameters

ParameterTypical Value
Power Supply120V / 230V AC, 50/60 Hz (or 24V/48V DC for some models)
Number of Outputs4–16 (depending on system configuration)
Flash Rate Range30–180 flashes per minute (programmable)
Flash Duration50–200 ms (programmable per output)
Delay Between Outputs50–200 ms (programmable)
Timing Accuracy±1 ms (crystal‑controlled); ±1 µs (GPS‑synchronised)
Control InterfaceRS‑232, RS‑485, Ethernet (Modbus/TCP, IEC 60870‑5‑104)
Intensity Control0–10V, 4‑20mA, or digital interface to CCR
DiagnosticsBuilt‑in self‑test, fault logging, remote status reporting
RedundancyOptional dual units with automatic failover
Operating Temperature‑40°C to +70°C
Protection ClassIP65 (indoor/outdoor enclosure)
Mounting19" rack mount or wall‑mount enclosure
ComplianceFAA AC 150/5345‑51, ICAO Annex 14, FAA Order 6850.2
Power Supply

Electrical Requirements

RequirementTypical Value
Input Power120V / 230V AC, 50/60 Hz (or 24V/48V DC), single-phase
Power ConsumptionTypically < 100 W (excludes downstream Flasher Power Supply loads)
Control WiringShielded twisted-pair, RS-485, or Ethernet cable to each Flasher Power Supply / Synchronisation Unit
Output Signal TypeTTL, RS-232/RS-485, or Ethernet trigger signals — low voltage, low current (not the SFL lamp circuit itself)
IsolationOptically isolated or transformer-isolated control outputs to downstream flasher power supplies
GroundingChassis and enclosure bonded to equipment shelter/building earth
Surge ProtectionSurge protective devices on incoming mains and communication ports
Backup PowerUPS or battery backup recommended to maintain synchronisation through mains interruptions
Fault ProtectionInternal fuse/circuit breaker on incoming supply
Cable TypeScreened control cable rated for airfield duct/shelter routing
Compliance

Applicable Standards

ICAO Annex 14

Flasher control unit requirements for sequenced flashing lights in approach lighting systems

FAA AC 150/5345-51

Specification for Discharge-Type Flashing Light Equipment (REIL, ODALS, and SFL flasher control)

FAA Order 6850.2

Visual Guidance Lighting Systems – ALSF‑1 and ALSF‑2 configuration

IEC 61000-6-2

EMC immunity for industrial control equipment

RTCA DO‑160

Environmental conditions and test procedures for airborne equipment (referenced for compatibility)

Prerequisites

Installation Requirements

Enclosure Mounting
Mechanical

Fit the rack-mount chassis or wall enclosure in the equipment room within cable reach of the CCRs and flasher power supplies it coordinates.

Power Supply Connection
Electrical

Terminate the AC or DC supply at the labelled terminal block, confirming voltage matches the unit's rating before the control board is energised.

Trigger Output Wiring to Flasher Power Supplies
Electrical

Run and terminate the trigger wiring to each Flasher Power Supply channel, keeping runs identified and labelled to avoid cross-connection between channels.

ALCMS/Manual Control Interface Wiring
Electrical

Terminate the incoming ALCMS or manual control interface at the rear or base terminal blocks, confirming the protocol and signal levels match the design.

Surge Protection Fitting
Electrical

Confirm surge protection is fitted to each trigger output, since field wiring to the flasher power supplies is exposed to lightning-induced transients.

Channel & Timing Configuration
Systems

Program flash rate, flash duration, and inter-output delay for each channel to match the design sequence before any live testing begins.

Pre-Energisation Sign-off
Documentation

Record power connection, trigger wiring, and channel configuration as-built before the unit is first energised.

Verification

Testing & Commissioning

Power-Up & Self-Test
Pre-Energisation

Confirm the unit powers up cleanly and passes its internal self-test/diagnostics before connecting to the live SFL string.

Trigger Output Sequence Verification
Energisation

Verify each numbered trigger output fires in the correct order using an oscilloscope or test lamp before live SFL units are connected.

Timing & Delay Sequence Accuracy Test
Energisation

Measure the inter-position delay against the design step time (typically 50–200 ms) and confirm it holds across the full sequence.

ALCMS Communication Link Test
Final Acceptance

Confirm command and status telemetry — flash rate, on/off, RVR-linked intensity step, and fault reporting — exchanges correctly with the ALCMS.

Synchronization Lock Verification
Final Acceptance

Where a Flasher Synchronization Unit is present, confirm the control unit locks to the master clock and the sequence shows no drift.

Redundancy Failover Test
Final Acceptance

Simulate a primary unit fault and confirm the standby control unit takes over automatically without a visible break in the rolling sequence.

Documentation & As-Built Sign-off
Final Acceptance

Record trigger sequence, timing accuracy, and communication test results in the commissioning dossier for handover.

Upkeep

Inspection & Maintenance

Timing & Sequence Accuracy Check
Semi-annual

Verify the flash sequence timing remains accurate, since drift or jitter can affect the coordinated approach light pattern.

Communication Link Test
Semi-annual

Test the link to the ALCMS to catch intermittent communication loss before it masks a real fault.

Power Supply Check
Annual

Verify power input stability and inspect the supply for signs of stress or ageing.

Output Circuit Test
Annual

Test output circuits to catch developing faults before they affect fixture flashing.

Firmware & Configuration Audit
Annual

Review firmware version and configuration against baseline to catch unplanned drift.

Enclosure Condition Check
Annual

Inspect the enclosure for environmental degradation such as seal wear or corrosion.

Field Notes

Common Field Issues

Timing Drift and Sequence Jitter

Over time, the timing accuracy of the Flasher Control Unit can drift due to crystal ageing or temperature variations. This can cause the flash sequence to become irregular, reducing the effectiveness of the "rolling" effect. Regular calibration and, in critical installations, GPS time synchronisation are recommended.

Communication Failures with ALCMS

The Flasher Control Unit relies on reliable communication with the ALCMS for remote control and monitoring. Cable damage, connector corrosion, or network issues can cause loss of control or status reporting. Regular inspection and testing of communication links are essential.

Power Supply Instability

Flasher Control Units require stable power for precise timing. Voltage fluctuations or transient spikes can cause timing errors or lock‑ups. UPS protection and power quality monitoring are recommended for critical installations.

Output Circuit Failures

Individual output circuits can fail due to component ageing or transient overvoltage. This can cause one or more SFL units to stop flashing, breaking the sequence. Regular output testing and replacement of faulty output modules are recommended.

Firmware and Configuration Errors

Incorrect programming of the flash sequence, flash rate, or output delays can cause the SFL system to flash incorrectly, confusing pilots. Careful configuration management and verification are essential during installation and maintenance.

Environmental Degradation

Flasher Control Units installed in outdoor shelters or cabinets are exposed to temperature extremes, humidity, and dust. Regular cleaning of vents, inspection of seals, and checking of cooling fans are recommended to prevent overheating or moisture ingress.

Diagnostics

Troubleshooting Guide

Flash Sequence Irregular or "Rolling" Effect Degraded
Likely Cause
Timing drift from crystal ageing or temperature variation in the unit's internal clock.
Diagnostic Steps
Check timing accuracy against a reference clock or GPS time source; review recent calibration records.
Corrective Action
Recalibrate the unit's timing, and consider adding GPS time synchronisation for critical installations.
Loss of Remote Control or Status Reporting
Likely Cause
A communication fault with the ALCMS from cable damage, connector corrosion, or a network issue.
Diagnostic Steps
Inspect communication cabling and connectors for damage or corrosion; test the link status between the unit and the ALCMS.
Corrective Action
Repair or replace the damaged cable/connector and confirm communication is restored and stable.
Timing Errors or Unit Lock-Up
Likely Cause
Power supply instability, including voltage fluctuations or transient spikes, disrupting the unit's precise timing.
Diagnostic Steps
Monitor input power quality at the unit; check for recent transient events on the supply.
Corrective Action
Install or verify UPS protection and power quality monitoring, and reset the unit once stable power is confirmed.
One or More SFL Units Stop Flashing
Likely Cause
An output circuit failure from component ageing or a transient overvoltage event on that channel.
Diagnostic Steps
Test each output circuit individually against its expected signal; identify the failed channel.
Corrective Action
Replace the faulty output module and re-test the full sequence to confirm the affected SFL units resume flashing.
Sequence Flashes in the Wrong Order or at the Wrong Time
Likely Cause
Incorrect programming of flash sequence, rate, or output delays, often from a configuration change that wasn't fully verified.
Diagnostic Steps
Review the unit's current configuration against the design flash sequence and timing plan.
Corrective Action
Correct the configuration and verify the full sequence against the design plan before returning to service.
Unit Overheating or Showing Moisture Ingress
Likely Cause
Environmental degradation from outdoor shelter/cabinet exposure to temperature extremes, humidity, and dust.
Diagnostic Steps
Inspect vents, seals, and cooling fans for blockage or damage; check internal temperature if monitoring is available.
Corrective Action
Clean vents and fans, replace degraded seals, and confirm cooling airflow is restored before returning to service.
Reliability

Failure Modes & Root Causes

Internal Clock Timing Drift
Medium Severity
Root Cause
Crystal ageing or temperature variation affecting the unit's internal timing reference.
Effect
The flash sequence becomes irregular, degrading the intended 'rolling' effect of the SFL system.
Detection Method
Timing accuracy check against a reference clock or GPS time source, reviewed against calibration records.
ALCMS Communication Failure
High Severity
Root Cause
Cable damage, connector corrosion, or a network issue on the link between the unit and the ALCMS.
Effect
Loss of remote control or status reporting for the flasher system.
Detection Method
Inspection of communication cabling and connectors, and a link status test between the unit and the ALCMS.
Power Supply Instability
High Severity
Root Cause
Voltage fluctuations or transient spikes on the unit's incoming power.
Effect
Timing errors or a complete lock-up of the unit, disrupting the flash sequence.
Detection Method
Monitoring of input power quality at the unit, checking for recent transient events.
Output Circuit Failure
High Severity
Root Cause
Component ageing or a transient overvoltage event on an individual output channel.
Effect
One or more SFL units stop flashing, breaking the overall sequence.
Detection Method
Individual testing of each output circuit against its expected signal to identify the failed channel.
Firmware / Configuration Error
Medium Severity
Root Cause
Incorrect programming of the flash sequence, flash rate, or output delays, often after an unverified configuration change.
Effect
The SFL system flashes in the wrong order or at the wrong time, potentially confusing pilots.
Detection Method
Review of the unit's current configuration against the design flash sequence and timing plan.
Environmental Degradation of the Enclosure
Medium Severity
Root Cause
Outdoor shelter or cabinet exposure to temperature extremes, humidity, and dust over time.
Effect
Overheating or moisture ingress inside the unit, risking component damage.
Detection Method
Inspection of vents, seals, and cooling fans for blockage or damage, with internal temperature checks where available.
Precautions

Safety & Operational Notes

Circuit Isolation Before Internal Work
Electrical Safety

De-energise and lock out the unit's power feed before opening its enclosure or disconnecting internal wiring, and verify zero energy before handling connections.

Trigger Output Is Not the High-Energy Circuit
Electrical Safety

Be aware that the unit's trigger outputs are low-voltage signalling lines, not the high-voltage discharge path; treat the connected Flasher Power Supply and its capacitor bank as the hazardous energy source and isolate it separately before working downstream of a trigger connection.

Confirm Control Authority Before Overriding a Sequence
Operational

Confirm with the ALCMS or control room which system has control authority before switching the unit to manual or test mode, since an uncoordinated override can disrupt the rolling flash sequence pilots rely on during an approach.

Coordinate Sequence Testing with Operations
Operational

Notify air traffic control or airfield operations before running a manual test sequence on an active approach lighting system, since an irregular flash pattern during testing could be misread by an approaching aircraft.

PPE & Grounding
Personnel Safety

Use insulated tools and appropriate PPE when working inside the unit's enclosure, and confirm the chassis is bonded/grounded per the electrical design before reconnecting.

ESD Precautions
Personnel Safety

Use anti-static handling precautions when removing or inserting cards or modules, since the unit's microprocessor and timing crystal electronics can be damaged by electrostatic discharge.

FOD Control at the Enclosure
Operational

Keep tools and fasteners accounted for at all times when the unit is open, and secure or remove any loose material before closing it.

Restore to Compliant State
Compliance

Do not leave the unit in manual or test mode, or reporting a self-diagnostic fault, after maintenance; confirm it has returned to normal automatic sequencing and correct flash timing before closing out the work.

Field Insight

Engineering & Expert Notes

Timing Crystal Aging Is Slow but Cumulative
Reliability

A timing crystal's frequency drifts very slightly with age and thermal cycling, and while any single unit's drift is negligible, cumulative drift across a chain of control units over years of service can eventually produce a rolling sequence that's subtly out of phase. Periodic sequence-timing verification against a reference catches this before it becomes visually noticeable.

Verify Sequence Direction After Any Unit Replacement
Commissioning

A replacement control unit configured with the wrong address or sequence position can flash in the correct pattern but out of the correct order relative to its neighbours, which is easy to miss on a quick visual check but confusing to a pilot relying on the directional cue. Confirm sequence order end-to-end after any unit swap, not just that the replaced unit flashes.

Firmware Updates Can Change Timing Behaviour Subtly
Configuration

A firmware update intended to fix an unrelated issue can shift default timing parameters or rounding behaviour in the sequence generation logic; re-verify sequence timing after any firmware change rather than assuming an update that fixed one thing left everything else unchanged.

Isolate Trigger Signal Wiring From High-Energy Flasher Power Cabling
Electrical

The low-level trigger signals to each SFL unit are vulnerable to induced noise from the adjacent high-energy discharge cabling that powers the actual flash; route and shield trigger wiring separately, since induced noise on the trigger line can cause a missed or extra flash that looks like a control unit fault.

Keep Redundant Control Units on Matched Configuration
Reliability

As with any redundant controller pair, a standby Flasher Control Unit with a different firmware revision or configuration than the primary can fail to reproduce the correct sequence on failover; version-lock and periodically test the standby unit under simulated failover conditions.

Distinguish a Sequencing Fault From an Individual Lamp Fault Before Dispatch
Troubleshooting

A gap or stutter in the rolling effect can originate either from the control unit's sequence logic or from a single failed SFL lamp; check the control unit's own diagnostic log for the affected position before assuming a field lamp replacement will resolve it.

Quick Answers

Frequently Asked Questions

Short answers about flasher control units in sequenced flashing light (SFL) systems: what they do, timing, interfaces, standards, maintenance and common faults.

Q1What is a flasher control unit?

A flasher control unit, also called an SFL controller or sequence controller, generates and manages the timed trigger signals for sequenced flashing lights in approach lighting. It is the brain behind the rolling or chasing effect that gives pilots a directional cue on final approach.

Q2What does a flasher control unit do?

It receives input from the ALCMS or manual controls and outputs synchronised trigger pulses to each SFL unit along the approach path, flashing from the outer end toward the runway threshold. The precise delay between each light is what makes the flashes read as motion.

Q3What timing does the unit produce?

Delay between outputs is typically 50–200 ms and flash duration 50–200 ms, at 30–180 flashes per minute (all programmable). Timing accuracy is ±1 ms for crystal control and ±1 µs when GPS-synchronised.

Q4Which approach lighting systems use it?

ALSF-1 and ALSF-2 (CAT I, II, III), MALSF and MALSR, Calvert II systems, runways with low-visibility operations (RVR below 800 m) and major CAT II/III airports.

Q5What outputs and interfaces does it have?

4–16 outputs carrying TTL, RS-232/RS-485 or Ethernet trigger signals to the flasher power supplies or synchronisation unit, not the lamp circuit itself. Control interfaces include RS-232, RS-485 and Ethernet (Modbus/TCP, IEC 60870-5-104), with an optional dual unit with automatic failover.

Q6Where is a flasher control unit installed?

Rack- or panel-mounted in the equipment shelter or CCR room serving the approach lighting, close to the flasher power supply and synchronisation unit, and wired into the ALCMS network for remote monitoring and control where fitted. A UPS or battery backup keeps synchronisation through mains interruptions.

Q7Which standards apply to flasher control units?

The main references are ICAO Annex 14, FAA AC 150/5345-51 (discharge-type flashing light equipment), FAA Order 6850.2 (ALSF-1 and ALSF-2), IEC 61000-6-2 and RTCA DO-160. Always verify the current edition and your approved requirements.

Q8How often should a flasher control unit be maintained?

Typical intervals are semi-annual for timing and sequence accuracy checks and communication link tests, and annual for power supply checks, output circuit tests, firmware and configuration audit and enclosure condition checks. Your approved maintenance programme takes precedence.

Q9Why is the flash sequence irregular or the rolling effect degraded?

Timing drift from crystal ageing or temperature variation. Check timing against a reference clock or GPS time source, recalibrate, and consider GPS time synchronisation for critical installations.

Q10Why has remote control or status reporting been lost?

A communication fault with the ALCMS from cable damage, connector corrosion or a network issue. Inspect the cabling and connectors, test the link between the unit and the ALCMS, and repair or replace the damaged part.

Go Further

Go Beyond the Component. Understand the Complete AGL System.

You have explored the component. Now understand how it works within the complete Airfield Ground Lighting system.

Learn AGL from fundamentals to design, installation, testing, photometry, commissioning, maintenance and troubleshooting through structured technical training at Precision AGL Academy.

Build practical knowledge. Understand the circuit. Read the standards. Troubleshoot with confidence.

Your next step in AGL starts here.

The Learning Pathway
Learn Understand Design Test Maintain Document Apply Certify