RVR Sensor
A specialised sensor that measures Runway Visual Range (RVR) — the distance over which a pilot can see runway surface markings or lights. Essential for CAT I, II, and III low‑visibility operations, providing real‑time data for approach and take‑off minima.
Image disclaimer: For identification and illustration only. It may show a product by another manufacturer and may not depict the exact item described; it is not a statement of any product’s quality, approval or performance. Third-party image and trademark rights belong to their owners. See full notice.
What Is It?
An RVR Sensor (Runway Visual Range sensor) is a ground‑based instrument that measures the horizontal visibility along a runway, specifically the distance at which a pilot can see runway centreline or edge lights. RVR is a critical parameter for low‑visibility operations, as it determines the approach and take‑off minima for CAT I, II, and III operations. The sensor typically uses forward‑scatter or transmissometer technology, combined with ambient light measurements, to calculate the RVR value in metres or feet. RVR data is displayed to air traffic controllers and pilots, and is used to decide whether to continue, hold, or divert an approach.
Purpose & Function
An RVR sensor exists because the decision to attempt or continue an approach in fog, heavy rain, or blowing snow can't safely be left to a pilot's own estimate of how far ahead they can see — visibility close to the surface changes quickly and unevenly, and the margin for misjudgement narrows sharply as conditions deteriorate toward CAT II/III minima. By measuring visibility directly and continuously at points along the runway, the sensor gives controllers and pilots a shared, objective number to base a go/no-go decision on rather than a subjective impression.
Because RVR is used to set the actual approach and take-off minima for a given category of operation, this single measurement effectively determines whether an approach is legally permitted at all in low visibility — making the sensor's accuracy and reliability directly tied to whether an airport can keep operating safely as weather worsens, rather than shutting down entirely.
Where Is It Used?
Installed at airports that support precision approaches, typically at the touchdown zone (TDZ), mid‑point, and stop end of the runway. For CAT II and III operations, multiple RVR sensors are required along the runway. The sensors are mounted on masts or poles beside the runway, at a height of approximately 2.5 metres above the pavement, and are oriented to measure visibility in the direction of the approach. RVR data is used by ATC, airline operations, and automated weather systems to issue RVR reports for each runway.
Installation & Location
Sensors are mounted on masts or poles set beside the runway strip, clear of the obstacle-free zone, at each measurement point required for the runway category, typically the touchdown zone, mid-point, and stop end for CAT II/III operations. Mounting height is fixed at approximately 2.5 m above the pavement so the measurement path represents the pilot's eye height on approach, and each sensor's optical baseline is aligned along the runway so the reading reflects visibility in the direction of travel rather than across it. The mast foundation is set back from the runway edge at the mandated lateral clearance, with power and data cabling run underground in duct back to the AWOS/RVR processing cabinet. Sensor heads are orientated so the optical path avoids facing directly into low sun angles, which can otherwise introduce measurement error.
How Does It Work?
An RVR sensor combines a visibility sensor (forward‑scatter or transmissometer) with an ambient light sensor (photometer). The visibility sensor measures the Meteorological Optical Range (MOR) by detecting scattered light from a known volume of air. The ambient light sensor measures the background luminance (daylight, twilight, or night). The RVR is then calculated using the Allard‑Koschmieder relationship, which accounts for the contrast threshold of the human eye and the intensity of runway lights. The sensor outputs RVR in metres (or feet) at specified reporting intervals (typically every 1 minute). The system includes self‑diagnostics to ensure data integrity, and is calibrated against reference standards.
System Architecture & Control Logic
A single RVR reading isn't what gets reported — the AWOS/RVR processor aggregates the TDZ, mid-point, and stop-end values (where all three are fitted) and applies the operationally relevant selection logic on top: the value ATC actually reports and pilots are briefed on is typically the controlling RVR, the lowest of the relevant readings for the operation being conducted, since that's the point along the runway where visibility genuinely limits the approach or take-off. Each sensor also runs continuous self-diagnostics — checking optical alignment, window contamination, and internal calibration drift — and reports its health status to the processor separately from its visibility reading, so a fouled or drifting unit can be flagged and excluded from the controlling-value calculation rather than silently corrupting it. From the processor, the controlling RVR and the individual sensor values are distributed in parallel to the ATC tower display, into METAR/ATIS reporting, and — on airports where the two systems are linked — as an input the ALCMS can use to recommend or automatically select the appropriate runway lighting intensity step for the prevailing visibility.
Sensor health and the visibility measurement travel together, not separately — a unit reporting a marginal or out-of-tolerance self-check is treated differently from one silently returning a bad number, which is why the processor's controlling-value logic needs the diagnostic status as much as it needs the RVR figure itself.
Installation Positions & Calculation Overview
RVR isn't read directly off one instrument — it's calculated. The visibility sensor measures Meteorological Optical Range and the photometer measures background luminance separately; the Allard–Koschmieder relationship combines the two, accounting for the human contrast threshold and runway light intensity, to produce the reported value. CAT II/III runways repeat this whole chain at TDZ, midpoint, and stop end, since visibility can genuinely differ along the runway's length.
Physical Construction
An RVR sensor is built around a forward-scatter or transmissometer optical head, with the transmitter and receiver (or the transmitter, receiver, and separate baseline reflector, in transmissometer designs) mounted on rigid arms or towers set a fixed, calibrated distance apart. The optical housings are weatherproof enclosures, typically aluminium or composite, rated to IP66/IP67, with heated windows or hoods over the lenses to prevent condensation, frost, or precipitation from obscuring the measurement path. The mounting structure is a fixed steel or aluminium frame or pole set beside the runway at the standard reference height above the surface, engineered to hold the optical alignment stable against wind loading and vibration since even small angular drift between transmitter and receiver would introduce measurement error. An integrated ambient light (background luminance) sensor is mounted alongside the main optical head to correct the RVR calculation for daylight and lighting conditions. All external cabling to the processing unit is armoured or conduit-protected given the sensor's exposed siting close to the runway, and the frame and fasteners are corrosion-resistant to withstand continuous outdoor exposure and de-icing fluid contact.
Technical Parameters
| Parameter | Typical Value |
|---|---|
| Measurement Range (RVR) | 30 m – 2,000 m (up to 6,000 ft) |
| Accuracy (RVR) | ±10% or ±30 m (whichever is greater) for RVR < 600 m |
| Visibility Sensor Type | Forward‑scatter or transmissometer |
| Ambient Light Sensor | Photometer (visible spectrum, photopic response) |
| Mounting Height | 2.5 m above runway surface (ICAO) |
| Output Signal | RS‑232, RS‑485, Ethernet, or 4–20 mA |
| Reporting Interval | 1 minute (nominal) |
| Protection Class | IP66 / IP67 (weatherproof) |
| Operating Temperature | -40°C to +60°C |
Electrical Requirements
| Requirement | Typical Value |
|---|---|
| Power Supply | 100–240V AC, 50/60Hz (or 24V DC on remote-powered installations) |
| Power Consumption | ~50–150W, including optics/window heater load |
| Heater Elements | Integrated anti-icing/anti-condensation heaters on lens, window, and photometer housing |
| Signal/Data Cable | Shielded twisted-pair or Ethernet run to AWOS/ALCMS data logger |
| Surge Protection | Lightning and surge arrestors on both power and signal lines |
| Earthing/Grounding | Sensor housing and mounting mast bonded to airfield earth grid |
| Backup Power | UPS or battery backup recommended for continuous RVR reporting |
| Power Source | Dedicated circuit from AWOS power distribution panel or airfield electrical supply |
Applicable Standards
ICAO Annex 3
RVR measurement and reporting requirements
ICAO Doc 9328
Manual of Runway Visual Range Observing and Reporting Practices — applies Annex 3's RVR provisions to sensor siting, calculation, and reporting
FAA AC 150/5220-16
Airport weather observation systems (AWOS) RVR requirements
WMO No. 8 (Guide to Instruments)
RVR measurement principles and sensor specifications
Installation Requirements
Mast Foundation & Lateral Clearance
CivilSet the mast foundation back from the runway edge at the mandated lateral clearance, clear of the obstacle-free zone.
Measurement Point Positioning
CivilSite sensors at each measurement point required for the runway category — typically touchdown zone, mid-point, and stop end for CAT II/III operations.
Cable Route to Processing Cabinet
ElectricalRun power and data cabling underground in duct back to the AWOS/RVR processing cabinet, armoured or conduit-protected given the exposed siting.
Optical Baseline Alignment
MechanicalSet the sensor at approximately 2.5 m above the pavement with its optical baseline aligned along the runway so readings reflect visibility in the direction of travel.
Transmitter/Receiver Baseline Calibration
MechanicalConfirm the transmitter, receiver, and any separate baseline reflector are mounted at the fixed, calibrated distance apart the design requires.
Ambient Light Sensor Fitting
MechanicalMount the integrated ambient light sensor alongside the main optical head, orientated to avoid facing directly into low sun angles.
Heated Window Wiring
ElectricalTerminate the heated window/hood circuit so condensation, frost, or precipitation cannot obscure the measurement path.
Pre-Energisation Sign-off
DocumentationRecord mast position, cable route, and optical alignment as-built for each measurement point before commissioning.
Testing & Commissioning
Insulation Resistance & Continuity Test
Pre-EnergisationMegger-test power cabling and verify signal cable continuity before the unit is energised, ruling out faults introduced during installation.
Power-Up & Self-Diagnostics
EnergisationEnergise the unit and confirm the visibility sensor and ambient light sensor both pass their internal self-diagnostic checks.
Visibility Sensor Calibration Check
Functional TestVerify the forward-scatter or transmissometer element against a certified reference scatter plate or calibration standard.
Ambient Light Sensor (Photometer) Calibration
Functional TestVerify the photometer's background luminance reading against a reference light source across the day/twilight/night range.
RVR Algorithm Cross-Check
Functional TestCompare the calculated RVR output against a reference instrument reading, confirming the Allard-Koschmieder calculation is producing accurate values.
Siting & Baseline Alignment Verification
Functional TestFor transmissometer-based systems, confirm the transmitter and receiver baseline is correctly aligned and free of obstruction.
Communications & Output Interface Test
Final AcceptanceConfirm RVR values report correctly to the AWOS and ATC display at the specified reporting interval before handover.
Documentation & As-Built Sign-off
Final AcceptanceRecord calibration, alignment, and communications test results alongside as-built position in the commissioning dossier for handover.
Inspection & Maintenance
Calibration Verification
AnnualCheck sensor output against a certified reference instrument across the measurement range to confirm the ±10%/±30m accuracy specification is still being met.
Optical Window Cleaning
MonthlyClean the transmissometer or forward-scatter optical windows, since dust, insects, or condensation on the optics directly skews RVR readings that feed low-visibility operations.
Sensor Alignment Check
AnnualConfirm the forward-scatter or transmissometer baseline alignment remains within tolerance, since drift here degrades measurement accuracy without an obvious fault indication.
Ambient Light Sensor Check
Semi-annualVerify the photometer used for background luminance compensation reads correctly, since RVR calculation depends on accurate ambient light input.
Output Signal & Communication Link Test
Semi-annualConfirm the sensor's RS-232/RS-485/Ethernet/4-20mA output reaches the AWOS or ALCMS correctly and at the specified 1-minute reporting interval.
Heater / De-icing Function Check
AnnualTest any heating elements on the optical housing ahead of the icing season, since frost or ice on the sensor optics can cause false low-visibility readings.
Seal & Weatherproofing Inspection
AnnualCheck housing seals and gaskets for cracking or degradation and confirm the IP66/IP67 rating is still intact.
Mounting Height Verification
AnnualConfirm the sensor remains at the ICAO-specified 2.5m mounting height above the runway surface, since ground settlement or resurfacing can shift this over time.
Common Field Issues
Lens Contamination and Window Fouling
Dirt, dust, bird droppings, and de‑icing fluids on the optical windows of the visibility sensor and photometer can cause significant errors in RVR readings. Regular cleaning with lens‑safe solutions is essential, especially during winter operations.
Calibration Drift and Alignment
Both the visibility sensor and the ambient light sensor can drift over time, affecting RVR accuracy. Annual calibration using certified reference standards and alignment checks are required to maintain ICAO tolerances.
Electrical Noise and Grounding
RVR sensors are sensitive to electrical noise from nearby equipment (e.g., radar, CCRs). Proper shielding, grounding, and surge protection are critical to ensure accurate and stable measurements.
Icing and Snow Accumulation
In cold climates, ice can form on the sensor windows or housing, blocking the optical path. Heated window options are available, but regular visual inspection and de‑icing procedures are recommended.
Troubleshooting Guide
One Sensor Position (TDZ/Mid/Stop-End) Excluded from Controlling RVR
RVR Reading Suspiciously Low Given Visible Conditions
Erratic or Noisy RVR Readings Near Other Airfield Equipment
Optical Path Blocked by Ice or Snow
No Output or Data Dropout to AWOS/ALCMS
Failure Modes & Root Causes
Optical Window Contamination
Optical Alignment or Scatter-Geometry Drift
Calibration Drift
Electrical Noise / Grounding Fault
Heated Window Failure / Icing
Output Communication Link Failure
Safety & Operational Notes
Electrical Isolation Before Servicing
Electrical SafetyDe-energise the transmissometer/forward-scatter sensor's mains supply and the separate optics/window heater circuit before opening the transmitter, receiver, or photometer housing, and verify zero energy before handling connectors.
Hot Surfaces from Heater Elements
Personnel SafetyAllow the integrated anti-icing/anti-condensation heaters on the lens, window, and photometer housing to cool before handling after active operation, especially during winter maintenance.
Runway Proximity and Airside Coordination
OperationalRVR sensor sites sit close to or within the runway strip; any work requires ATC/airside coordination and a NOTAM for degraded or unavailable RVR reporting, with personnel and vehicles kept clear per the aerodrome's safety management procedures.
Optical Alignment Precision
OperationalTransmitter-to-receiver alignment on baseline-type units is sensitive to small angular shifts; use the manufacturer's alignment procedure and confirm signal strength rather than alignment by eye alone, since a subtly misaligned unit can still report plausible but inaccurate values.
FOD Control at the Sensor Site
OperationalKeep tools, fasteners, and lens-cleaning materials accounted for at all times when the housing is open, and secure or remove loose material before closing out work, given the site's proximity to the runway movement area.
PPE and Grounding
Personnel SafetyUse insulated tools on mains-powered connections and confirm the sensor mast/housing bonding and grounding are intact before reconnecting supply.
Restore to Compliant State
ComplianceVerify RVR output against a reference or cross-check with an adjacent sensor before closing out the work, and cancel the associated NOTAM once reporting is confirmed within tolerance.
Engineering & Expert Notes
Optical Window Contamination Reads as False Low Visibility
MaintenanceInsects, spider webs, or debris in the forward-scatter sample volume produce a false low-visibility reading rather than an obvious fault; inspect optical windows on a tighter cycle during insect-prone seasons rather than relying on the standard maintenance interval.
Cross-Check Paired Units Along the Runway
VerificationWhere multiple RVR sensors exist along the runway, a persistent disagreement between units is diagnostic in itself; compare readings between paired sensors regularly rather than validating each one only against its own internal self-check.
Verify Against a Certified Reference, Not Just Self-Check
CalibrationThe internal scatter reference used for self-calibration can itself degrade gradually over time; verify against an external certified reference target on a defined interval rather than trusting the sensor's own self-check indefinitely.
Test the Defogging Heater Separately From Optical Calibration
TroubleshootingCondensation on the lens from a failed heater mimics a genuine low-visibility reading rather than presenting as a clear equipment fault; verify heater cycling behaviour on its own rather than assuming a passed optical calibration means the heater is also working.
Re-Check Siting After Nearby Lighting Changes
SitingNew taxiway or apron lighting installed after commissioning can introduce stray light into the sensor's ambient light measurement, biasing results; re-verify siting against nearby light sources periodically, not only during initial installation.
Confirm Averaging Settings Match Operational Needs
ConfigurationAn averaging period left at a generic default can smooth out rapidly changing fog conditions in a way that delays a genuinely fast-developing low-visibility event; confirm the configured averaging period matches the operational requirement for the site rather than assuming the factory default is appropriate.
Frequently Asked Questions
Short answers about RVR sensors: how they work, mounting, standards and maintenance.
Q1What is an RVR sensor?
An RVR (Runway Visual Range) sensor is a ground-based instrument that measures horizontal visibility along a runway, in terms of the distance at which a pilot can see runway centreline or edge lights. It is critical for low-visibility precision approaches.
Q2How does an RVR sensor work?
It combines a visibility sensor, either forward-scatter or transmissometer, that measures the Meteorological Optical Range (MOR) with an ambient light sensor (photometer), and converts the readings into RVR using the runway light intensity setting.
Q3Where are RVR sensors installed?
At airports supporting precision approaches, typically at the touchdown zone, mid-point and stop-end of the runway. The page gives a mounting height of 2.5 m above the runway surface.
Q4What is the measurement range of an RVR sensor?
Typically 30 m to 2,000 m (up to about 6,000 ft), with a nominal reporting interval of 1 minute and outputs such as RS-232, RS-485, Ethernet or 4-20 mA.
Q5What is the difference between MOR and RVR?
MOR is the atmospheric visibility measured by the sensor. RVR is what a pilot on the centreline can see of runway lights, so it also depends on the light intensity setting and ambient background light.
Q6Which standards apply to RVR sensors?
The main references are ICAO Annex 3, ICAO Doc 9328 (manual of RVR observing and reporting practices), FAA AC 150/5220-16 and WMO No. 8 (Guide to Instruments).
Q7How often should an RVR sensor be maintained?
Monthly optical window cleaning, and annual calibration verification against a certified reference and sensor alignment checks.
Q8What are the common problems with RVR sensors?
Window fouling from dirt, bird droppings and de-icing fluids, calibration and alignment drift, electrical noise and grounding issues, and ice or snow accumulation in cold climates.
Related Components
Go Beyond the Component. Understand the Complete AGL System.
You have explored the component. Now understand how it works within the complete Airfield Ground Lighting system.
Learn AGL from fundamentals to design, installation, testing, photometry, commissioning, maintenance and troubleshooting through structured technical training at Precision AGL Academy.
Build practical knowledge. Understand the circuit. Read the standards. Troubleshoot with confidence.
Your next step in AGL starts here.
Need expert guidance on RVR sensor selection, installation, or calibration?
Precision AGL Academy provides advice on RVR system design, sensor placement, and compliance with ICAO and FAA requirements for low‑visibility operations.
Follow the Academy
Important Notice, Disclaimer & Limitation of Liability
Please read before relying on any content on this page.
- Purpose and intended users. This page on RVR Sensor is an independent educational and informational reference for competent, suitably trained and authorised airfield ground lighting (AGL) and aerodrome electrical personnel. It is not professional engineering, legal or regulatory advice, and using it does not create any professional or client relationship.
- Safety. Work on series circuits, constant current regulators (CCRs), isolating transformers, cables, connectors and lighting equipment can be fatal. Always apply the aerodrome’s permit-to-work and isolation/LOTO procedures, prove dead, use correctly rated instruments and PPE, and follow the manufacturer’s instructions. Nothing here authorises work on live equipment or the bypassing of any safety device or interlock.
- Aviation operations. Nothing here authorises installation, modification, energisation, adjustment, return to service, a change of operating category (CAT I/II/III), a NOTAM or any aerodrome certification or approval decision. These rest with the aerodrome operator, the air navigation service provider and the competent regulator.
- Specifications, ratings and typical values. Descriptions, parameters, ratings, dimensions, photometric values, wattages, service lives, maintenance tasks and intervals, failure modes, certifications (for example CE, FCC, UL or IEC marks) and part or type designations are general, typical and indicative. They may not match any particular product, make, model or version, and they are not a datasheet, design, specification, selection, sizing, procurement or acceptance criterion. The manufacturer’s current documents, the approved design and the project specification prevail.
- Standards and regulations. References to ICAO, FAA, IEC, IEEE, ISO, BIS, DGCA and other standards are paraphrased summaries for orientation only. They may be incomplete or out of date, and standards are revised from time to time. Consult the current official editions. Following this content does not guarantee compliance with any law, standard or regulatory approval, and the regulator’s requirements always prevail.
- No warranty. Content is provided “as is” and “as available”, without warranty of any kind, express or implied, including accuracy, completeness, currency or fitness for a particular purpose. Real installations differ in design, equipment make and model, age and condition.
- Limitation of liability. To the fullest extent permitted by applicable law, Precision AGL Academy, Precision AGL Solutions and their owners, authors and contributors are not liable for any injury, death, loss, damage, downtime, penalty or regulatory consequence, whether direct or indirect, arising from the use of, reliance on, or inability to use this content. Nothing in this notice excludes or limits any liability that cannot lawfully be excluded or limited.
- Independence, brands and no endorsement. This is an independent publication. It is not affiliated with, sponsored by or endorsed by ICAO, the FAA, the IEC, DGCA, AAI, any airport, regulator, supplier or equipment manufacturer. Third-party names, product designations, standard designations and trademarks (including Megger®, Siemens, Eaton, Crouse-Hinds, ADB SAFEGATE, Fluke, ABB and Honeywell) belong to their respective owners and are used only for identification and description. Mention of a brand, product or supplier is not a recommendation, and we do not sell, supply or quote for any component described.
- Images and third-party content. Images and illustrations are shown to help identify the type of component. They may show products of various manufacturers, may not depict the exact item described, and are not a statement about any product’s quality, approval or performance. Copyright and trademarks in third-party images, logos and photographs belong to their respective owners and are not claimed as ours. If you are a rights holder and want an image removed, replaced or credited, email precisionaglsolutions@gmail.com with the page address and we will act promptly.
- Training and services. Mentions of training, courses, consultation, advice, selection, installation, calibration or other support, including the “Learn…Certify” pathway, describe learning stages and are not an offer, quotation, tender or promise of any result. Contacting us or our replying creates no engagement or duty of care; an engagement exists only under a written agreement. We are not a regulator or certification body, and completing any course or reading this content is not a certification, accreditation or authorisation to work on any aerodrome.
- Copyright, privacy and corrections. © 2026 Precision AGL Academy. All rights reserved. Text, structure, compilations and diagrams may be viewed for personal reference and internal training only; any other copying, republication or commercial use needs our written permission. If you email, telephone or message us, we use your details only to respond and handle your matter, in line with applicable Indian law including the Digital Personal Data Protection Act, 2023; please do not send confidential or security-sensitive information. To display this page your browser requests fonts, icons and images from third-party servers, which receive your IP address and browser details under their own policies. Content is reviewed periodically with no obligation to update. To report an error, safety concern or rights issue, write to precisionaglsolutions@gmail.com.