Image disclaimer: For identification and illustration only. It may show a product by another manufacturer and may not depict the exact item described; it is not a statement of any product’s quality, approval or performance. Third-party image and trademark rights belong to their owners. See full notice.
What Is It?
A Temperature Sensor is a meteorological instrument used to measure ambient air temperature, and often pavement surface temperature, at an airfield. It is an essential component of aerodrome weather observation systems, providing data for METAR, TAF, and ATC briefings. Temperature data is used for aircraft performance calculations (density altitude, take‑off and landing distances), winter maintenance decisions (anti‑icing, de‑icing, snow removal), and for general weather reporting. The sensor typically uses a platinum resistance thermometer (PRT), thermistor, or thermocouple, and is housed in a radiation shield to protect it from solar radiation and precipitation.
Purpose & Function
Airfield temperature data exists to support decisions that go well beyond a simple weather report: aircraft performance calculations depend on air density, which shifts with temperature and directly affects how much runway length a takeoff or landing actually requires. In hot conditions, an aircraft can need significantly more runway to become airborne safely, so accurate, continuously updated temperature readings feed directly into the performance margins pilots and dispatchers rely on before every departure.
On the ground-operations side, pavement and ambient temperature readings are what trigger winter maintenance decisions — when to apply anti-icing chemicals, when frost risk becomes real, and when de-icing becomes mandatory before an aircraft can depart safely. Getting this timing right protects against the loss of lift and control that ice or frost contamination on wings and control surfaces can cause.
Where Is It Used?
Installed at airfields as part of the meteorological observation system, typically at a height of 1.5 to 2 metres above ground level, in a well‑ventilated location away from buildings and heat sources. Temperature sensors are used for weather reporting, ATC information, and input to automated systems such as RVR and weather displays. Pavement temperature sensors are embedded in the runway or taxiway surface to provide data for winter maintenance and friction assessment. They are also used at heliports, remote airstrips, and offshore platforms where temperature data is essential for safe operations.
Installation & Location
Air temperature sensors are mounted inside a ventilated radiation shield on a mast or stand, sited over natural ground cover in an open area away from buildings, pavement, and other heat sources, at the standard meteorological height of 1.5–2 m above ground level. Pavement (surface) temperature sensors are instead embedded flush into the runway or taxiway structure during construction or resurfacing, wired in armoured cable run through duct to the roadside cabinet, with the sensing face set level with the surrounding surface so it doesn't disturb aircraft tyre contact or snow-clearing equipment. In both cases, cabling runs underground back to the meteorological equipment shelter or AWOS cabinet, and siting keeps the sensor clear of sprinkler and de-icing spray and vehicle exhaust paths that could bias readings.
How Does It Work?
An air temperature sensor uses a sensing element (e.g., a platinum resistance thermometer) whose electrical resistance changes predictably with temperature. The sensor is connected to a data logger or weather processor that measures the resistance and converts it to a temperature reading (in °C, °F, or K). The sensor is housed in a radiation shield (often a louvred, passive or fan‑aspirated shield) to minimise the effects of solar heating and to allow free airflow. Pavement temperature sensors are typically embedded in the surface and use similar sensing technology, but are designed to withstand heavy loads and environmental exposure. The output signal is typically 4–20 mA, 0–10 V, or digital (RS‑232, RS‑485, SDI‑12).
System Architecture & Control Logic
The data logger's job doesn't stop at converting resistance to a temperature reading — the AWOS layer above it applies threshold-based alarm logic that turns a raw number into an operational decision. Pavement temperature is continuously compared against the current dew point: when the gap narrows to within a defined margin, the system raises a frost-risk alert to the winter maintenance team well before ice actually forms, rather than waiting for a human observer to notice. Similarly, a sustained pavement or air temperature drop toward freezing triggers a de-icing/anti-icing readiness alert distinct from the routine METAR/TAF reporting cycle. This threshold layer runs independently of, and faster than, the standard reporting interval, because a winter-ops decision can't wait for the next scheduled weather bulletin. The sensor's own health — resistance drift, open-circuit, or out-of-range readings — is checked continuously and reported as a separate maintenance fault, so a failing sensor triggers a service call rather than silently feeding a bad reading into the frost-alert logic.
Sensing & Data Path Overview
Air and pavement sensors use the same sensing principle — a Pt100 or thermistor whose resistance changes predictably with temperature — and differ mainly in packaging: a ventilated radiation shield versus a surface-rated housing built to take wheel loads. Both feed the same data logger, which is really the fork point: one reading, converted once, is what METAR/TAF reporting, winter maintenance calls, and RVR/weather displays all read from.
Physical Construction
A temperature sensor is built around a platinum resistance thermometer, thermistor, or thermocouple element housed in a radiation shield — typically a louvred, naturally or fan-aspirated white plastic or aluminium enclosure — that protects the sensing element from direct solar radiation and precipitation while allowing free airflow so the reading reflects true ambient air temperature rather than the shield's own surface temperature. The shield and sensor assembly mount on a fixed pole or bracket at the standard reference height above ground, with the sensing element itself sealed in a small stainless-steel or corrosion-resistant probe housing rated to IP65/IP66. Where pavement temperature is also measured, a separate flush-mounted or surface-contact probe is embedded in or bonded to the pavement surface, wired back to the same signal processing unit as the air temperature sensor. Cabling from the sensing element to the transmitter or data logger is shielded and weather-rated, and the enclosure housing the electronics is sealed against moisture ingress, since the sensor is typically sited in an open, unobstructed location with full exposure to wind, rain, and temperature extremes.
Technical Parameters
| Parameter | Typical Value |
|---|---|
| Measurement Range (Air) | -50°C to +60°C |
| Measurement Range (Pavement) | -40°C to +80°C |
| Accuracy | ±0.2°C (class A PRT) or ±0.5°C |
| Resolution | 0.1°C (typical) |
| Response Time | 10–30 seconds (depending on housing) |
| Sensing Element | Platinum RTD (Pt100), thermistor, or thermocouple |
| Mounting Height (Air) | 1.5–2 m above ground (WMO / ICAO) |
| Output Signal | 4–20 mA, 0–10V, RS‑232, RS‑485, or SDI‑12 |
| Protection Class | IP65 / IP66 (weatherproof) |
| Operating Temperature | -40°C to +80°C |
Electrical Requirements
| Requirement | Typical Value |
|---|---|
| Power Supply | 12–24V DC (loop-powered transmitter) or 100–240V AC for heated pavement housings |
| Power Consumption | < 5W unheated; higher on heated in-pavement or de-icing variants |
| Signal/Data Cable | Shielded twisted-pair instrumentation cable, direct-burial rated for embedded pavement sensors |
| Output Loop | 4–20 mA current loop, RS-485, or SDI-12 to RTU/data logger |
| Surge Protection | Surge arrestors on both power and signal lines |
| Earthing/Grounding | Sensor body and cable shield bonded to airfield earth grid |
| Insulation Resistance | ≥ 50 MΩ (megger test, cable-to-ground) for buried pavement sensor runs |
| Power Source | RTU/data logger power supply or dedicated low-voltage circuit |
Applicable Standards
ICAO Annex 3
Meteorological service requirements for temperature reporting
WMO No. 8 (Guide to Instruments)
Temperature measurement instrument specifications and installation
FAA AC 150/5220-16
Airport weather observation systems (AWOS) requirements
IEC 60751
Platinum resistance thermometers (PRT) standards
Installation Requirements
Radiation Shield Mounting
MechanicalMount the air temperature shield on its mast or stand at the standard 1.5–2 m height over natural ground cover, away from buildings, pavement, and heat sources.
Pavement Probe Embedding
CivilWhere fitted, embed the pavement sensing face flush with the surrounding surface during construction or resurfacing so it doesn't disturb tyre contact or snow-clearing.
Cable Route to Equipment Shelter
ElectricalRun armoured cable through duct from the pavement probe, and shielded weather-rated cable from the air sensor, back to the meteorological equipment shelter or AWOS cabinet.
Siting Clearance Check
CivilConfirm the air sensor location is clear of sprinkler and de-icing spray paths and vehicle exhaust that could bias readings.
Sensing Element Termination
ElectricalTerminate the RTD, thermistor, or thermocouple element to the signal processing unit or transmitter, sealing all connections against moisture ingress.
Pre-Energisation Sign-off
DocumentationRecord shield/probe position and cable route as-built before the sensor is accepted for commissioning.
Testing & Commissioning
Insulation Resistance & Continuity Test
Pre-EnergisationMegger-test power cabling and verify signal cable continuity before the sensor is energised, ruling out faults introduced during installation.
Power-Up & Self-Test
EnergisationEnergise the sensor and confirm it passes its internal self-diagnostic routine with no fault codes before proceeding to calibration.
Reference Calibration Check
Functional TestVerify the sensing element's reading against a certified reference thermometer or ice-bath standard across the expected operating range.
Radiation Shield/Aspiration Fan Function Test
Functional TestConfirm the radiation shield is correctly fitted and, where fan-aspirated, that the aspiration fan runs correctly to prevent solar-heating error.
Output Signal Verification
Functional TestConfirm the output signal (4-20mA, 0-10V, or digital) is clean and reports correctly to the data logger or weather processor.
Pavement Sensor Embedment Check
Functional TestFor embedded pavement sensors, confirm correct flush-mounting depth and that the surrounding surface meets load and finish tolerances.
Response Time Verification
Final AcceptanceConfirm the sensor's response time to a step change in temperature meets specification before operational handover.
Documentation & As-Built Sign-off
Final AcceptanceRecord calibration, output, and response time test results alongside as-built position in the commissioning dossier for handover.
Inspection & Maintenance
Calibration Verification
AnnualCheck sensor output against a certified reference thermometer to confirm the ±0.2°C/±0.5°C accuracy specification is still being met.
Sensing Element Inspection
AnnualInspect the PRT, thermistor, or thermocouple element for drift, corrosion, or connection degradation that could bias readings.
Radiation Shield Cleaning
QuarterlyClean the radiation shield of dust and debris so it continues to protect the sensing element from solar heating error, keeping reported air temperature accurate.
Output Signal & Communication Link Test
Semi-annualConfirm the sensor's 4-20mA/0-10V/RS-485/SDI-12 output reaches the AWOS or ALCMS correctly and without signal noise.
Seal & Weatherproofing Inspection
AnnualCheck housing seals and gaskets for cracking or degradation and confirm the IP65/IP66 rating is still intact.
Mounting Height Verification
AnnualConfirm air-temperature sensors remain at the WMO/ICAO-specified 1.5–2m height above ground, since site changes can shift this out of tolerance.
Cable & Connector Inspection
AnnualExamine signal and power wiring for corrosion or loose terminations, a common source of erratic or dropped-out readings.
Response Time Verification
AnnualTest the sensor's response to a step temperature change to confirm it still settles within the specified 10–30 second window.
Common Field Issues
Radiation Shielding Degradation
Over time, the radiation shield can become dirty or degraded, affecting its ability to reflect solar radiation and allow free airflow, leading to elevated temperature readings. Regular cleaning and inspection of the shield are recommended.
Calibration Drift
PRT and thermistor sensors can drift over time due to thermal cycling and environmental exposure. Annual calibration against a certified reference thermometer is required to maintain accuracy.
Pavement Sensor Damage
Embedded pavement temperature sensors are subject to heavy aircraft loading, freeze‑thaw cycles, and de‑icing chemicals, which can cause damage or failure. Regular inspection and replacement as per manufacturer recommendations are essential.
Condensation and Moisture Ingress
Moisture can enter the sensor housing through damaged seals or cable glands, causing corrosion and electrical faults. Regular seal checks and the use of moisture‑absorbing desiccants can mitigate this issue.
Troubleshooting Guide
Reading Suspiciously High During Sunny, Calm Conditions
Frost-Risk Alert Not Triggering When Expected
Pavement Sensor Reading Erratic or Failed
Air and Pavement Sensors Disagree with Expected Relationship
No Data Reaching METAR/TAF or Winter Maintenance Systems
Failure Modes & Root Causes
Radiation Shield Fouling or Failure
Sensing Element Calibration Drift
Pavement Probe Physical Damage
Seal or Gasket Failure (Moisture Ingress)
Output / Communication Link Failure
Safety & Operational Notes
Electrical Isolation Before Servicing
Electrical SafetyDe-energise the loop-powered transmitter supply, and separately the heater circuit on heated in-pavement or de-icing variants, before disconnecting cable or opening the sensor housing; verify zero energy at the termination point.
Hot Surfaces on Heated Variants
Personnel SafetyAllow heated in-pavement or de-icing sensor housings to cool before handling after active operation, since these can retain significant heat well after the heater circuit is switched off.
Pavement Work Coordination
OperationalExcavating or re-setting an in-pavement embedded sensor requires ATC/airside coordination, a NOTAM, and pavement closure per the aerodrome's safety management procedures, with the surrounding surface reinstated to the required load rating before reopening.
FOD Control
OperationalKeep tools, fasteners, and excavated material accounted for at all times when the sensor or its pavement housing is open, and clear the area of debris before reinstating the surface.
Insulation and Loop Test Before Re-Energisation
Electrical SafetyTest the signal loop and, where fitted, the heater circuit for insulation integrity after cable or connector work before restoring power, since a residual fault can produce a false reading rather than an obvious failure.
Restore to Compliant State
ComplianceConfirm the sensor reports within its accuracy specification and the surrounding pavement or turf is reinstated to the required standard before closing out the work and cancelling the associated NOTAM.
Engineering & Expert Notes
Radiation Shield Contamination Biases Readings Warm
MaintenanceDust film or bird droppings on the radiation shield create a radiative heating bias that looks like a genuinely elevated reading; clean and inspect the shield as its own maintenance item, separate from sensor electronics calibration.
Verify Excitation Configuration Matches Manufacturer Spec
CalibrationCertain sensor types exhibit a small self-heating error under incorrect excitation current settings; confirm the sensor electronics configuration matches the manufacturer's specification to avoid a persistent bias that a routine calibration check might not isolate.
Test the Aspiration Fan, Not Just the Sensor Element
TroubleshootingA stalled aspiration fan removes the shield's compensation for solar loading, producing a warm bias mainly on sunny, low-wind days that can be hard to spot in cloudy conditions; test fan operation specifically rather than inferring it from a passed sensor calibration.
Track Pavement Sensors Separately From Air Temperature Sensors
MaintenanceSurface wear and de-icing chemical exposure affect a pavement temperature sensor differently than an air temperature string exposed to the same weather; maintain and calibrate each on its own schedule rather than assuming one check covers both.
Cross-Check Against a Portable Reference at Calibration
VerificationA single-point calibration check can miss a small but real shift that only shows up against an independent reference; compare against a nearby independent sensor or portable calibrated reference periodically rather than relying solely on the sensor's own calibration routine.
Noisy Readings Point to Connections Before the Sensor Element
TroubleshootingCorroded connectors on buried cable runs can produce intermittent readings that resemble real rapid temperature swings; inspect cable connections first when readings show unusual noise rather than assuming the sensor element itself has failed.
Frequently Asked Questions
Short answers about airfield temperature sensors: measurement, mounting, standards and maintenance.
Q1What is an airfield temperature sensor?
It is a meteorological instrument that measures ambient air temperature, and often pavement surface temperature, as part of the aerodrome weather observation system.
Q2How does an airfield temperature sensor work?
A sensing element such as a platinum resistance thermometer (Pt100) changes electrical resistance predictably with temperature. A data logger or weather processor converts that resistance into a temperature reading.
Q3What is the measurement range and accuracy?
Air temperature range is about -50°C to +60°C and pavement about -40°C to +80°C, with accuracy of ±0.2°C for a class A PRT or ±0.5°C, and a resolution of 0.1°C.
Q4At what height should an air temperature sensor be mounted?
The page gives 1.5 to 2 m above ground, in line with WMO and ICAO practice.
Q5Why measure pavement temperature?
Embedded pavement sensors give surface temperature data that supports operational decisions such as icing and surface condition monitoring.
Q6Which standards apply to temperature sensors?
The main references are ICAO Annex 3, WMO No. 8 (Guide to Instruments), FAA AC 150/5220-16 and IEC 60751 for platinum resistance thermometers.
Q7How often should a temperature sensor be maintained?
Annual calibration against a certified reference thermometer and sensing element inspection, plus quarterly cleaning of the radiation shield.
Q8What are the common problems with temperature sensors?
Radiation shield degradation, calibration drift from thermal cycling, damage to embedded pavement sensors from aircraft loading, and condensation or moisture ingress through damaged seals or cables.
Related Components
Go Beyond the Component. Understand the Complete AGL System.
You have explored the component. Now understand how it works within the complete Airfield Ground Lighting system.
Learn AGL from fundamentals to design, installation, testing, photometry, commissioning, maintenance and troubleshooting through structured technical training at Precision AGL Academy.
Build practical knowledge. Understand the circuit. Read the standards. Troubleshoot with confidence.
Your next step in AGL starts here.
Need expert guidance on temperature sensor selection, installation, or calibration?
Precision AGL Academy provides advice on weather system design, sensor siting, and compliance with ICAO and WMO standards.
Follow the Academy
Important Notice, Disclaimer & Limitation of Liability
Please read before relying on any content on this page.
- Purpose and intended users. This page on Temperature Sensor is an independent educational and informational reference for competent, suitably trained and authorised airfield ground lighting (AGL) and aerodrome electrical personnel. It is not professional engineering, legal or regulatory advice, and using it does not create any professional or client relationship.
- Safety. Work on series circuits, constant current regulators (CCRs), isolating transformers, cables, connectors and lighting equipment can be fatal. Always apply the aerodrome’s permit-to-work and isolation/LOTO procedures, prove dead, use correctly rated instruments and PPE, and follow the manufacturer’s instructions. Nothing here authorises work on live equipment or the bypassing of any safety device or interlock.
- Aviation operations. Nothing here authorises installation, modification, energisation, adjustment, return to service, a change of operating category (CAT I/II/III), a NOTAM or any aerodrome certification or approval decision. These rest with the aerodrome operator, the air navigation service provider and the competent regulator.
- Specifications, ratings and typical values. Descriptions, parameters, ratings, dimensions, photometric values, wattages, service lives, maintenance tasks and intervals, failure modes, certifications (for example CE, FCC, UL or IEC marks) and part or type designations are general, typical and indicative. They may not match any particular product, make, model or version, and they are not a datasheet, design, specification, selection, sizing, procurement or acceptance criterion. The manufacturer’s current documents, the approved design and the project specification prevail.
- Standards and regulations. References to ICAO, FAA, IEC, IEEE, ISO, BIS, DGCA and other standards are paraphrased summaries for orientation only. They may be incomplete or out of date, and standards are revised from time to time. Consult the current official editions. Following this content does not guarantee compliance with any law, standard or regulatory approval, and the regulator’s requirements always prevail.
- No warranty. Content is provided “as is” and “as available”, without warranty of any kind, express or implied, including accuracy, completeness, currency or fitness for a particular purpose. Real installations differ in design, equipment make and model, age and condition.
- Limitation of liability. To the fullest extent permitted by applicable law, Precision AGL Academy, Precision AGL Solutions and their owners, authors and contributors are not liable for any injury, death, loss, damage, downtime, penalty or regulatory consequence, whether direct or indirect, arising from the use of, reliance on, or inability to use this content. Nothing in this notice excludes or limits any liability that cannot lawfully be excluded or limited.
- Independence, brands and no endorsement. This is an independent publication. It is not affiliated with, sponsored by or endorsed by ICAO, the FAA, the IEC, DGCA, AAI, any airport, regulator, supplier or equipment manufacturer. Third-party names, product designations, standard designations and trademarks (including Megger®, Siemens, Eaton, Crouse-Hinds, ADB SAFEGATE, Fluke, ABB and Honeywell) belong to their respective owners and are used only for identification and description. Mention of a brand, product or supplier is not a recommendation, and we do not sell, supply or quote for any component described.
- Images and third-party content. Images and illustrations are shown to help identify the type of component. They may show products of various manufacturers, may not depict the exact item described, and are not a statement about any product’s quality, approval or performance. Copyright and trademarks in third-party images, logos and photographs belong to their respective owners and are not claimed as ours. If you are a rights holder and want an image removed, replaced or credited, email precisionaglsolutions@gmail.com with the page address and we will act promptly.
- Training and services. Mentions of training, courses, consultation, advice, selection, installation, calibration or other support, including the “Learn…Certify” pathway, describe learning stages and are not an offer, quotation, tender or promise of any result. Contacting us or our replying creates no engagement or duty of care; an engagement exists only under a written agreement. We are not a regulator or certification body, and completing any course or reading this content is not a certification, accreditation or authorisation to work on any aerodrome.
- Copyright, privacy and corrections. © 2026 Precision AGL Academy. All rights reserved. Text, structure, compilations and diagrams may be viewed for personal reference and internal training only; any other copying, republication or commercial use needs our written permission. If you email, telephone or message us, we use your details only to respond and handle your matter, in line with applicable Indian law including the Digital Personal Data Protection Act, 2023; please do not send confidential or security-sensitive information. To display this page your browser requests fonts, icons and images from third-party servers, which receive your IP address and browser details under their own policies. Content is reviewed periodically with no obligation to update. To report an error, safety concern or rights issue, write to precisionaglsolutions@gmail.com.