What is MTTR in airfield lighting?

The average time it takes to put a failed light or circuit back in service. Most of it is usually spent detecting, getting there and waiting for parts, not fixing.

MTTR THE AVERAGE TIME FROM FAILURE UNTIL THE LIGHTS ARE BACK AND TESTED WORKED EXAMPLE · 4 FAILURES · 32 HOURS DOWN MTTR = 32 hours ÷ 4 failures = 8 hours WHERE ONE 8-HOUR RESTORATION GOES DETECT 1.5 h ACCESS 2.5 h PARTS 2 h FIX 1 h TEST 1 h ONLY 1 OF THE 8 HOURS IS HANDS-ON REPAIR HALVE THE MTTR, HALVE THE DOWNTIME · MTBF 2,000 H 8 H MTTR · 35 H 99.60% 4 H MTTR · 17.5 H 99.80% BARS = HOURS DOWN IN A YEAR · ILLUSTRATIVE HOW MTTR IS CUT 1 DETECT FASTER alarms and monitoring flag the fault 2 GET THERE FASTER crew on call, airside permits ready 3 HOLD THE SPARES right parts on site or in the van 4 DESIGN FOR REPAIR plug-in connectors, accessible pits 5 DIAGNOSE QUICKLY labels, as-built records, test gear 6 TEST AND HAND BACK a clear, quick return to service THE METHOD 1 DEFINE START AND END 2 LOG EVERY OUTAGE 3 ADD UP THE DOWNTIME 4 DIVIDE BY FAILURES 5 SPLIT BY STAGE 6 ATTACK THE LONGEST STAGE SCHEMATIC · ILLUSTRATIVE HOURS · REAL MTTR COMES FROM TIMED OUTAGE RECORDS
detect
access
parts
repair
test and hand back
The Fact Engineering concept

MTTR, mean time to repair, is the average time taken to put a failed item back in service. In airfield lighting the useful version runs from the moment the lighting fails until it is working, tested and handed back, because that is the time operations are without it. Together with MTBF it sets availability.

1Downtime divided by failures

MTTR = total downtime ÷ number of failures. In the example, four outages of 2, 4, 8 and 18 hours add up to 32 hours, so the MTTR is 8 hours. The average hides the spread: the single 18-hour outage is more than half of the total, so look at the longest outages as well as the mean. Also decide and state when the clock starts and stops, since MTTR is used for two different things in practice.

Active repair time

Hands-on locating and fixing the fault, and nothing else.

Restoration time

Detect, get there, fetch parts, repair, test and hand back: the whole outage.

2Mostly waiting, not fixing

In the example only 1 of the 8 hours is hands-on repair. The rest is detecting the fault, getting a crew airside with a permit, and fetching spares, which is why a faster pair of hands barely changes the result while a standing permit or a spare in the van changes it a lot. Splitting each outage by stage shows where the time really goes.

StageWhat happensHow it is shortened
DetectThe fault is noticed, reported and confirmedAlarms, monitoring, regular inspection
AccessA crew is called, briefed and cleared to work airsideStandby crews, standing permits, agreed procedures
PartsThe right spare is found and brought to siteSpares held to match the failures expected
RepairThe fault is located and fixedLabelled circuits, as-built records, plug-in connectors
Test and hand backChecks are made and the lights are returned to operationsStandard test sheet, clear handback to control

3MTTR and MTBF give availability

Availability is roughly MTBF ÷ (MTBF + MTTR). With an MTBF of 2,000 hours, an MTTR of 8 hours gives about 99.60% availability and 35 hours down a year, while 4 hours gives about 99.80% and 17.5 hours. Halving MTTR halves the downtime, and it is often cheaper than doubling the MTBF, because it needs spares, crews, permits and records rather than new equipment. The formula is an approximation that works best when MTTR is small compared with MTBF.

  1. Define start and end. From the moment of failure to tested and handed back.
  2. Log every outage. Times of failure, report, arrival, repair and handback.
  3. Add up the downtime. Total hours lost across all the failures.
  4. Divide by the failures. That is the MTTR for that definition.
  5. Split by stage. Detect, access, parts, repair, test and hand back.
  6. Attack the longest stage. Usually waiting, not the repair itself.
TermMeaning
MTTRMean time to repair or restore: total downtime ÷ number of failures
Active repair timeThe hands-on time spent locating and fixing the fault
Restoration timeEverything from failure until the lights are working, tested and handed back
Logistic delayTime spent waiting for a crew, a permit, access or a spare
DowntimeTime the function is not available
MTBFAverage operating time between failures, covered in Entry 27
AvailabilityShare of time the lighting is able to do its job, covered in Entry 26
Schematic: the four outages, the stage hours, the 2,000-hour MTBF and the availability figures are illustrative, not field data. The availability figures use the approximation MTBF ÷ (MTBF + MTTR). What counts as downtime, including planned maintenance, and the target MTTR depend on the airport’s own definition and maintenance objectives. Maintenance of visual aids is covered in ICAO Annex 14, Volume I, Chapter 10 and Doc 9137, Part 9; confirm against the editions in force. Terms follow IEC 60050-192 (dependability vocabulary).
Entry 27 · MTBF Entry 29 · Lifecycle engineering

Frequently Asked Questions

Q1What is MTTR in airfield lighting?

Mean time to repair, or restore: the average time taken to put a failed item back in service. It is total downtime divided by the number of failures.

Q2How is MTTR calculated?

Add up the downtime of every failure and divide by the number of failures. For example, four outages of 2, 4, 8 and 18 hours total 32 hours, so the MTTR is 8 hours.

Q3When does the MTTR clock start?

That depends on the definition, so state it. For availability the clock should start when the lighting fails, because that is when operations lose it, and stop when the lights are working, tested and handed back. Starting it when the crew arrives measures only part of the outage.

Q4Why is most of an outage not repair time?

Detecting the fault, getting a crew airside with a permit, and fetching the right spares often take longer than the hands-on work. In the example, 1 of the 8 hours is actual repair.

Q5How do MTTR and MTBF combine?

Availability is roughly MTBF divided by MTBF plus MTTR. With an MTBF of 2,000 hours, an MTTR of 8 hours gives about 99.60% availability, and halving the MTTR to 4 hours gives about 99.80%.

Q6What is a good MTTR?

There is no single figure. It depends on how critical the lights are and the operation they serve, and it is set by the airport's own maintenance objectives and target availability. Lights that must be restored quickly need faster detection, standby crews and spares on hand.

Precision AGL Academy

See It. Understand It. Then Learn How to Engineer It.

Recognising an AGL system visually is the first step. The next step is knowing how to design, install, test, commission and maintain them correctly.

Build Practical AGL Engineering Skills

Go deeper with structured training from Precision AGL Academy, covering:

AGL Fundamentals Design & Electrical Engineering Approach Lighting Photometry Installation & Commissioning Maintenance & Troubleshooting

Learn how each light, sign and circuit works as part of a complete airport lighting system, not just as an isolated diagram.

See. Understand. Apply. Engineer.