Home/AGL Study Notes/18 ICAO Annex 14 for AGL
AGL Study Notes · Note 18

ICAO ANNEX 14 FOR AGL COMPLETE NOTES

What the pilot must see, how the lights stay powered, and how they stay serviceable: Chapters 5, 8 and 10 with Appendix 2.

LightPowerMaintenancePhotometry
Summary of standards — not the standards themselves. These notes paraphrase published documents for learning. They may be incomplete or out of date and do not replace the current official edition, the regulator’s requirements or your project specification. Verify before any design, testing or compliance decision. Read the full notice ↓
1

WHAT IS ICAO ANNEX 14?

ICAO Annex 14 – Aerodromes holds the Standards and Recommended Practices (SARPs) for aerodromes. Volume I covers aerodrome design and operations (physical characteristics, obstacle limitation surfaces, visual aids, technical services); Volume II covers heliports. For runway and taxiway AGL, Volume I is the primary reference.

Annex 14Visual aid requirementLighting layoutElectrical systemFixture, transformer, cableControl and monitoringPhotometryMaintenanceServiceability
Memory
  • Chapter 5 = LIGHT (what the pilot sees)
  • Chapter 8 = POWER (how it keeps working)
  • Chapter 10 = MAINTENANCE (how it stays serviceable)
  • Appendix 2 = PHOTOMETRY (how output is defined)
ChapterSubjectAGL relevance
2Aerodrome dataVisual-aid information
3–4Physical characteristics, obstaclesGeometry, approach-light environment
5Visual aidsPrimary AGL chapter
6–7Obstacles, restricted-use areasObstacle lighting, closed runway lighting
8Electrical systemsAGL power
10MaintenanceAGL serviceability
Appendix 2Light characteristicsIsocandela diagrams, colour

Shall is a Standard; should is a Recommended Practice. Always read the full paragraph, including notes and exceptions.

2

CHAPTER 5: APPROACH LIGHTING AND PAPI

Chapter 5 splits into markings (5.2), lights (5.3) and signs (5.4), designed as one visual guidance system. Approach lighting gives alignment, runway identification, transition from instrument to visual guidance, and visual reference.

SystemKey points
CAT I precision approachCentreline row, wherever possible over 900 m from threshold, with a 30 m crossbar at 300 m; a shorter system can bring operational limits
CAT II/IIICentreline, two side rows, crossbars at 150 m and 300 m; side rows to 270 m (240 m alternative if serviceability is demonstrated); 900 m overall where possible
PAPI / APAPIVertical path guidance: white and red combinations show above, on or below slope. Engineer it as a system: optics, aiming, siting, obstacle protection, photometry, supply, control

The approach-light system should lie as nearly as practicable in the horizontal plane through the threshold; no object other than specified ILS/MLS antennas should protrude through it, and the pattern should not be screened from an approaching aircraft.

3

CHAPTER 5: RUNWAY LIGHTING

LightColour / rule
EdgeVariable white; the section at the remote end (from where the take-off run starts), 600 m or one-third of runway length whichever is less, shows yellow; red between the runway start and a displaced threshold, in the approach direction
ThresholdGreen (wing bars where applicable)
Runway endRed
Centreline (RCL)Required on CAT II/III; about 15 m spacing, 30 m permitted for RVR ≥ 300 m if serviceability objectives are demonstrated; on the centreline or uniformly offset by no more than 0.60 m; variable white to 900 m from the runway end, alternating red and white from 900 m to 300 m from the end, then red over the last 300 m; on runways shorter than 1,800 m the alternating section starts at the midpoint of the runway usable for landing (differs from the FAA 3,000/1,000 ft pattern)
Touchdown zone (TDZ)CAT II/III; paired barrettes (at least three lights each), fixed, unidirectional, variable white, extending 900 m from the threshold (not beyond the runway midpoint on runways under 1,800 m)
Rapid exit indicatorRecommended for low-RVR and heavy-traffic runways

Compare the FAA values in Note 19 and Note 21.

Remember
  • Threshold = GREEN, runway end = RED
  • Check runway direction before deciding which end is the "remote end"
  • PAPI aside, a pilot sees one pattern, not one lamp
4

CHAPTER 5: TAXIWAY, STOP BARS AND GUARD LIGHTS

Taxiway centreline lights are required on specified taxiways, de-icing facilities and aprons intended for RVR below 300 m. Straight sections: not more than 15 m. Curves need tighter spacing.

Curve radiusSpacing (guidance)
≤ 400 m7.5 m
401–899 m15 m
≥ 900 m30 m

Runway turn-pad lights (RVR below 300 m) guide a 180° turn onto the centreline. Where no stop bar exists, intermediate holding-position lights are required at positions used below 300 m RVR. Road-holding-position lights are required for low-RVR operations and recommended at higher RVR; take the exact thresholds from the current Annex text.

FeatureStop barRunway guard light
ColourRedYellow
MessageSTOPRunway-entry warning
LocationRunway holding position, across the taxiwayRunway holding position, beside or in the taxiway
ControlATS, interlocked with centreline lead-onSystem-dependent

Interlock: stop bar ON means red and stop; clearance switches the bar OFF and the lead-on centreline guidance ON, so the lights never give conflicting indications. Design so that one common fault cannot extinguish a whole stop bar.

Stop-bar provisions are tied to RVR thresholds: a Standard for low-RVR operations and a Recommended Practice at higher RVR (550 m is a commonly cited figure). Low-visibility thresholds were harmonised to 300 m by Amendment 18, so check the current Annex and your State's provisions before using any figure on a project.
5

AMENDMENT 18: 350 m BECOMES 300 m

Amendment 18 harmonized many low-visibility lighting thresholds from 350 m to 300 m: taxiway centreline lights, rapid exit indicators, turn-pad lights, intermediate holding-position lights, the 30 m runway centreline spacing limit (now RVR 300 m or more) and the serviceability criterion for taxiway centreline lights. Rapid exit, centreline, turn-pad and intermediate holding-position lights are now tied to RVR below 300 m, which is CAT III conditions, rather than CAT II. It also covers CAT II lighting harmonization, main-beam average intensity, threshold marking, closed runway lighting, unserviceability signs and runway distance remaining signs (300 m spacing where provided; the technical specification does not by itself require installation).

ItemDate
Annex 14 Vol. I9th Edition, July 2022
Amendment 18 adopted by ICAO Council28 March 2025
Amendment 18 effective4 August 2025
Design and visual-aid applicability27 November 2025
Ground handling / obstacle limitation surfaces applicability26 November 2026 / 21 November 2030
Corrigenda listed in the ICAO store (22 Oct 2026)No. 2 (18 Mar 2026), No. 3 (8 Jun 2026): read the current consolidated text
Do not reuse an old 350 m reference in a current project. No later amendment was listed in the ICAO store on 22 October 2026, but corrigenda have been issued. Confirm the dates and wording against the current ICAO catalogue and your State's implementation.
6

CHAPTER 8: ELECTRICAL SYSTEMS AND SWITCH-OVER

Chapter 8 asks how lighting stays powered when the normal supply fails. Secondary power applies to approach, runway and taxiway lighting in the applicable configurations. Architecture depends on category, lighting type, national rules and the approved design.

Mains failsUPS / fast sourceCritical AGL
Facility (CAT II/III)Max switch-over
Inner 300 m approach1 s
Other approach lighting15 s
Threshold, runway end, centreline, TDZ1 s
Stop bars1 s
Runway edge, essential taxiway15 s

A generator alone may not meet a 1 s load: use UPS or fast transfer for critical loads and the generator for sustained backup. Annex 14 states the operational need; the CCR must still deliver correct current, steps and monitoring (typically 6.6 A series circuits, from the approved design). Closed runway lighting must be supplied and controlled independently of the normal runway lighting.

Switch-over values follow Annex 14 Vol. I, Table 8-1 (secondary power supply requirements). Confirm against the current edition and your State's implementation before design use. The ICAO Asia-Pacific AOP Sub-Group (AOP/SG/9) has asked ICAO to review the 15 s requirement for the 300–900 m part of the CAT II/III approach system; Table 8-1 applies until an amendment changes it.
7

CHAPTER 10: MAINTENANCE AND SERVICEABILITY

A light is deemed unserviceable when its main-beam average intensity is below 50% of the applicable specified value (the higher design value where one applies). This is an individual-light test, not permission for 50% of the airport to fail.

CAT II/III elementObjective
Inner 450 m approach, RCL, threshold, edge95%
TDZ90%
Approach beyond 450 m85%
Runway end75%

CAT I: at least 85% for approach, threshold, edge and end lights, with continuity of guidance. Below 300 m RVR: no more than two stop-bar lights unserviceable and no two adjacent; no two adjacent taxiway centreline lights unserviceable.

Why percentage is not enough
  • Two failures side by side hurt the pattern more than two apart
  • Ask: how many are serviceable, where are the failures, is the pattern kept?
  • A light can be electrically healthy yet photometrically deficient
CriterionSourcePurpose
Below 50% of specified/design valueICAO Annex 14Light deemed unserviceable
About 70% of minimum output at maximum intensityFAA AC 150/5340-26CMaintenance targeting for in-pavement lights
Do not mix the ICAO 50% and FAA 70% figures; they serve different purposes. Confirm the serviceability table against Chapter 10 and Doc 9157 Part 4.
8

APPENDIX 2: PHOTOMETRY AND COLOUR

Appendix 2 holds the isocandela diagrams: intensity depends on direction, so "1000 cd" alone means little. For each critical fixture ask how bright, where it points and how far the beam extends. Measure with an approved method and geometry, and compare before and after cleaning (for example 68% before, 91% after shows contamination, not a failed fixture).

ColourTypical use
WhiteRunway and approach guidance
GreenThreshold, taxiway centreline
RedRunway end, stop bar
YellowHolding, guard lights, remote runway end
BlueTaxiway edge

Check each use against the Annex paragraph and figure. A trend such as 96% (2024), 89% (2025), 76% (2026) should trigger inspection before failure. Frangibility applies to elevated lights, signs, PAPI units and approach structures.

9

CONTROL, LVP AND STANDARDS HIERARCHY

ATC commands go through ALCMS/PLC/SCADA to CCRs, stop bars and monitoring. Selective switching lights only the needed taxi route, useful for low-visibility taxiing, stop bars and lead-on guidance. As visibility falls, lighting outweighs marking, and power, control and monitoring become critical.

LVP is not Annex 14 alone

Add certification, AIP, SMGCS/A-SMGCS, ATC procedures, RVR and navigation aids.

Do not blend standards

ICAO Annex 14, FAA AC 150-series and Indian regulation use similar ideas but different classes, photometry and criteria.

Annex 14State regulationAIPApproved designSpecificationDrawingsManufacturer data

A BOQ line "runway light as per ICAO" is not enough: define application, type, photometry, colour, intensity, electrical input, environment, connector, transformer, standard, tests and documents. Annex 14 gives the aerodrome-level requirement; it is not a product specification.

10

INSPECTION, COMMISSIONING AND FAULT-FINDING

Inspection

Identify, visual, electrical, optical, alignment, serviceability. For circuits follow CCR, cable, transformer, connector, fixture.

Commissioning

Design verification, installation, electrical, CCR, control, power failover, functional, photometry, alignment, serviceability, documents.

FAT / SAT

FAT at the factory (CCR, panels, ALCMS, UPS, fixtures, signs); SAT on site (location, orientation, intensity, control, interlocking, transfer, photometry).

Maintenance mix

Preventive (cleaning, IR tests, connectors), corrective (replace, repair), predictive (photometric and CCR trends, fault history).

Light failureCCR alarm?CableIsolating transformerL-823FixtureRepair and testPhotometry

"On" is not "healthy": contamination, misalignment or water ingress can leave electrical output normal and optical output low. Keep as-builts, schedules, photometric, IR and commissioning reports, calibration certificates and fault history. See Note 14 and Note 15.

11

QUICK REVISION

Critical numbers
  • 900 m: precision approach lighting length where possible
  • 300 m: Amendment 18 low-RVR harmonization point
  • 15 m / 30 m: RCL spacing; 0.60 m maximum offset
  • 50%: individual-light unserviceability
  • 95 / 90 / 85 / 75%: CAT II/III serviceability objectives
  • 1 s: critical CAT II/III switch-over
Exam & Interview

EXAM / INTERVIEW QUESTIONS

Which chapter is most important for AGL?

Chapter 5, Visual Aids for Navigation.

Which chapters cover power and maintenance?

Chapter 8 (electrical systems) and Chapter 10 (aerodrome maintenance).

Where are photometric characteristics specified?

Appendix 2, Aeronautical Ground Light Characteristics.

What colour is a stop bar, a runway guard light and a threshold?

Red, yellow and green.

What is the CAT II/III runway centreline requirement?

Centreline lights, about 15 m spacing; about 30 m permitted for RVR of 300 m or more when serviceability objectives are demonstrated.

What is the 50% criterion?

A light with main-beam average intensity below 50% of the applicable specified or design value is unserviceable. It is not the share of airport lights allowed to fail.

What changed in Amendment 18?

Many low-visibility thresholds moved from 350 m to 300 m.

Why is Chapter 8 vital for CAT II/III?

Several critical elements have 1 s switch-over requirements.

Why does failure location matter?

Adjacent failures break the visual pattern even when overall serviceability looks high.

Is Annex 14 a transformer specification?

No. It sets the aerodrome-level visual-aid requirement; product specs come from equipment standards, the project and national rules.

Final Study Takeaway

FINAL STUDY TAKEAWAY

Annex 14 defines the visual-aid system the pilot must receive, the electrical reliability behind it and the maintenance needed to keep it working.

Do not ask "is the light on?" Ask whether the right aid is in the right place, with the right colour, intensity, beam, alignment, power, control and serviceability.

Field Insight

ENGINEERING & EXPERT NOTES

Distinguish Standards From Recommendations

Terminology

The wording decides what is mandatory and what is advisory. Read it carefully before quoting it.

Cite the Amendment You Used

Currency

Annex content is amended. State the edition or amendment in any design or compliance note.

Remember the National Layer

Authority

States implement and may differ. Check the national regulation for the aerodrome in question.

Support Compliance With Measured Evidence

Verification

Photometry and colour data strengthen a compliance statement more than assumption.

References

REFERENCES & FURTHER READING

These notes are a study aid. Verify every figure against the current primary sources.

#SourceUse it for
1ICAO Annex 14 Vol. I, 9th Edition (July 2022), as amended up to Amendment 18 (effective 4 August 2025) and later corrigendaChapters 5, 8, 10 and Appendix 2
2ICAO Aerodrome Design Manual Doc 9157, Part 4 – Visual Aids; Part 5 – Electrical SystemsVisual-aid layout guidance and electrical systems
3ICAO Airport Services Manual Doc 9137, Part 9 – Airport Maintenance PracticesMaintenance practice and inspection guidance
4ICAO State Letter SL 2025/23 – Adoption of Amendment 18 to Annex 14, Volume IAdoption, effective and applicability dates
5FAA AC 150/5340-26CFAA maintenance targets (comparison only)
Go Further

Read the Notes. Close the Gaps. Build AGL Expertise.

Study notes give you the concepts and the exam logic — Precision AGL Academy is where they connect into real technical capability.

Learn how AGL fundamentals, systems, testing, photometry, maintenance and troubleshooting connect through structured technical training, well beyond what a set of notes can cover.

Study smarter. Train deeper. Build technical capability.

Take Your AGL Knowledge Further

Build structured knowledge in:

AGL Fundamentals Asset Management AGL Systems Electrical Engineering Maintenance Inspection Testing Photometry Troubleshooting Lifecycle Management

Talk to Precision AGL Academy

Follow the Academy