THE AGL ENGINEERING CENTRE by Precision AGL Academy · Test Procedure

AGL Photometric Testing Procedure Runway, Taxiway & PAPI

The practical field procedure: preparation, equipment set-up, measurement, evaluation, rectification, retesting and the final report, for runway, taxiway and PAPI lighting.

Overview

What Is AGL Photometric Testing?

AGL photometric testing measures the actual optical output of installed airport lighting and compares it with the applicable design, regulatory and project criteria. It is used after installation, during commissioning, periodic inspection and maintenance. A fitting can be electrically healthy, mechanically intact and lit during a visual inspection, and still fail photometrically through low intensity, wrong beam direction, inadequate coverage, wrong colour, abnormal distribution, incorrect aiming or inconsistency with adjacent fittings.

Document review
Equipment set-up
Measurement
Evaluation
Rectification
Retesting
Final report

A functional test asks

Does the light operate?

A photometric test asks

Does the light produce the required optical output in the required direction and configuration?

The 4Cs in AAI specifications

Configuration

Does the installed visual-aid arrangement match the required configuration?

Colour

Does the light have the required colour?

Candela

Measured luminous intensity.

Coverage

Is sufficient light provided over the specified field of view?

AAI procurement documents show in-field AGL testing can include intensity, beam spread, orientation, the 4Cs and chromaticity, plus field alignment and reporting. They also distinguish vehicle-mounted mobile testing from individual fitting measurement with portable or frame-based equipment.
THE DIAGRAM · ANGLE GRID curves of equal candela around the beam axis READING IT · BANDS AND SPACING between two curves, close or wide apart 50 % OF PEAK 10 % OF PEAK LEFT RIGHT UP HORIZONTAL AND VERTICAL ANGLE FROM THE BEAM AXIS P 1 2 3 4 PEAK 50 % 10 % P LIES BETWEEN 10 % AND 50 % OF PEAK read from the two curves around it 6 CLOSE steep fall WIDE gentle fall 5 1ANGLE GRIDhorizontal across, vertical up, beam axis at centre 2CURVE OF EQUAL CANDELAevery direction on it has the same intensity 3PEAK ON THE AXIShighest intensity, centre of the rings 4READ A DIRECTIONfind its angles, see the two curves around it 5CURVE SPACINGclose curves mean a quick change in intensity 6COMPARE WITH THE STANDARDmeasured against the required diagram CORRECT READINGBY ANGLE, THEN BETWEEN TWO CURVESDirection in, intensity band out WRONG READINGTHE PEAK VALUE ONLYSame peak, very different beams SCHEMATIC · ILLUSTRATIVE LEVELS · NOT A STANDARD DIAGRAM · SEE ICAO ANNEX 14 VOL. I, APP. 2
Figure 1. An isocandela diagram: curves join directions of equal intensity on a grid of horizontal and vertical angle.AGL Visual Encyclopedia: What is an isocandela diagram?
Parameters

What Parameters Are Measured?

ParameterWhat it covers
IntensityMeasured luminous intensity, generally in candelas
Photometric distributionDistribution of light over the required angular region
Beam spread and coverageWhether enough light reaches the specified field of view
Orientation and aimingThe actual direction in which the optics are aimed
ColourVerification of the required colour
ChromaticityObjective, quantitative colour measurement
ConfigurationInstalled arrangement matches the required one
Photometric diagramGraphical output where the equipment supports it
Unit-to-unit consistencyComparison of adjacent or equivalent fittings to expose abnormal ones

Photometry is required for

  • New installation and commissioning
  • Periodic inspection and preventive maintenance
  • Corrective maintenance (confirming a repair)
  • LED conversion baselines
  • Airport rehabilitation
  • Regulatory or airport inspection evidence

Five principles of a good programme

  • Correct equipment for the fitting type
  • Correct geometry per the approved method
  • Correct operating condition (current and intensity step)
  • Traceable equipment and results
  • Actionable reporting: which fittings passed, failed or need investigation
Equipment

Equipment, Calibration and Conditions

Photometer and sensor

An airport photometer or AGL field measurement system suited to the light category, with a calibrated sensor of suitable spectral and photometric characteristics.

Positioning and frame

Equipment to establish test location, angular position, sensor height, alignment, distance and orientation, plus a measurement frame for individual fittings.

Data and software

Data acquisition and software for photometric curves, intensity, aiming, pass/fail analysis, asset identification and reporting.

MethodBest for
Vehicle-mountedLong runways, extensive taxiways, large fitting populations, systematic surveys and high-volume periodic inspection
Handheld or frame-basedPAPI, individual lights, isolated defects, detailed investigation, post-maintenance retesting, workshop measurements
AAI's portable-equipment specification describes a standalone system for photometric and chromatic measurement of AGL and PAPI, with photometric diagrams, mean intensity and aiming angles, for field and laboratory use.

Verify before a formal survey

  • Instrument ID, serial number, calibration certificate and dates
  • Sensor configuration and software version
  • Condition of sensor lens, cables, connectors, frame, mounting hardware, battery, logger, communication links and vehicle installation

Record conditions the method requires

  • Date and time, temperature, weather
  • Visibility and precipitation
  • Pavement condition, ambient lighting, wind where relevant
Do not begin a formal acceptance survey with equipment whose calibration or verification status is unclear.
PHOTOMETER ARRANGEMENT · SIDE VIEW · SCHEMATICDARK ROOMBAFFLESdTEST DISTANCEFIXTURE ROTATES · PHOTOMETER STAYS FIXED123451FIXTURE ON STAGERotates to each test angle2BEAM AXISAimed at the photometer3TEST DISTANCELong enough for a point source4PHOTOMETERFixed detector reads the light5STRAY LIGHT CONTROLDark room and bafflesSCHEMATIC · PROPORTIONS ARE ILLUSTRATIVE, NOT A TEST SETUP DRAWING
Figure 2. Photometer arrangement: fixture, rotating stage and photometer set out so intensity can be read at each angle.AGL Visual Encyclopedia: What is a photometer arrangement?
Runway

Runway Photometry Procedure

Divide the runway into identifiable lighting groups and set the test route before measuring. The detailed test matrix follows the runway category and project specification.

01

Review runway data

Designation, layout, lighting type, fitting count, circuit identification and interleaving, locations, brightness levels, previous data. Create or verify the asset list.

02

Inspect the lighting

Missing fixtures, damaged or cracked lenses, contamination, wrong orientation, damaged housings, displaced elevated fittings, water ingress, damaged mountings.

03

Establish the measurement reference

Reference the system to runway geometry: centreline, longitudinal station, fixture location, test-track position, sensor orientation. A positioning error can look like an optical failure.

04

Set the lighting circuit

Energize at the specified operating condition; record test intensity, CCR setting and circuit condition.

05

Align the measurement system

Verify vehicle position, sensor height and orientation, frame geometry and reference direction. Start collecting only when the set-up is stable.

06

Measure each fitting or segment

Intensity, angular distribution, aiming, colour, chromaticity, coverage. Vehicle systems tie data to runway position; portable testing needs a unique ID per fitting.

07

Check abnormal measurements

Verify the set-up, repeat the reading, inspect the fitting, check the circuit, compare with neighbours, then consider electrical and mechanical causes. Do not classify an isolated odd reading as failure before confirming it.

By lighting type

Edge: output, colour, orientation, coverage. Threshold: directional performance and colour. Runway end: output, colour, orientation. Centreline: intensity, colour, configuration. Touchdown zone: intensity and direction where installed. Approach: the applicable optical and configuration parameters.

Circuit interleaving and LED

On redundant systems, test circuit A and B in normal condition and, where required, with each unavailable, to see whether the remaining pattern keeps the required characteristics. For LED fittings, measure rather than compare by eye: replacements, conversions, brightness stages, colour consistency and unit-to-unit variation.

The measurement grid and acceptance criteria come from the governing specification. FAA research on LED airfield lighting shows the value of photometric measurement for intensity and colour.
MEASUREMENT POINTS · ANGLE PLANE · SCHEMATIC(H, V)→ ONE cdHORIZONTAL ANGLEVERTICAL ANGLE00123451BEAM AXISAlways read: the peak and the aim2CONTOUR POINTSWhere the standard sets a minimum3EXTRA POINTSCloser, where intensity changes fast4OUTSIDE POINTSShow how fast the beam falls away5ANGLE PAIRH and V in, one candela value outSCHEMATIC · POSITIONS ARE ILLUSTRATIVE, NOT A REQUIRED POINT LIST
Figure 3. Measurement points: the horizontal and vertical angles at which intensity is read, chosen from the grid.AGL Visual Encyclopedia: What is a measurement point?
Taxiway

Taxiway Photometry Procedure

Same principle, adapted to taxiway geometry and the visual aid: edge lights, centreline lights, stop bars and runway guard lights.

01

Review the taxiway layout

Taxiway name, light type, circuit, directionality, sequence, intersections, stop bars, special lighting.

02

Visual inspection

Fixture damage, contamination, orientation, elevation, pavement around inset fittings, missing units.

03

Establish the test route

Define the route first on large networks to avoid missed fittings, duplicates and wrong asset IDs.

04

Energize the circuit

Set the required state. For dynamic systems such as controlled centreline segments, record which segments are commanded on.

05

Measure

Record the required photometric data.

06

Investigate abnormal units

Sensor set-up, fitting condition, aiming, connector, transformer, circuit condition.

Centreline lights

Verify optical output, colour, orientation, configuration and consistency. Where they support a Follow the Greens or A-SMGCS function, commissioning must also verify that the correct segment responds to the correct command. That control test is separate from photometry.

Stop bars and runway guard lights

Stop bars need two elements: an optical test (does the light give the required output?) and a functional or control test (does the right stop bar switch correctly?). A photometer cannot verify interlocking logic. Guard lights: operation, output, colour, orientation, and sequence or configuration where applicable.

Advanced taxiway guidance needs three different tests

TestQuestion
PhotometricDoes the green centreline fitting give the required optical output?
ControlDoes the correct green segment respond to the route command?
OperationalDoes the route indication behave correctly for the aircraft movement?
MEASUREMENT GRID · ANGLE vs ANGLEHORIZONTAL ANGLEVERTICAL ANGLEBEAM AXIS POINTcd READINGSTEP123451BEAM AXIS POINTCentre of the grid2MEASUREMENT POINTOne angle, one reading3GRID STEPAngular spacing of points4COVERAGEExtends past the beam edge5TABLE OF VALUESReadings form the resultsSCHEMATIC · SPACING AND EXTENT ARE ILLUSTRATIVE, NOT STANDARD VALUES
Figure 4. The photometric grid: angular points at which intensity is read so a whole beam is described by a table.AGL Visual Encyclopedia: What is a photometric grid?
PAPI

PAPI Photometry Procedure

PAPI output is deliberately split into precise white and red elevation sectors, so the survey combines physical inspection, aiming verification, photometry, colour measurement and functional testing.

01

Review PAPI information

Runway, PAPI position, unit IDs, design approach angle, approved elevations, MEHT/TCH where relevant, equipment type, previous measurements. AAI eAIP publishes position, angle and MEHT per runway direction: these are runway-specific design data, not generic equipment values.

02

Inspect physically

Lenses, optical surfaces, housing, mounting, foundation, drainage, connectors, transformer, alignment, surrounding vegetation or obstructions.

03

Verify horizontal alignment

All units correctly related to the runway reference.

04

Verify elevation and aiming

Measure each unit independently and confirm the optical axes match the approved aiming. ICAO material includes procedures for measuring PAPI settings and addresses UAS as an alternative method.

05

Energize the PAPI

Operate under the prescribed test condition.

06

Measure optical performance

Per unit: intensity, colour, angular characteristics, white/red transition, beam alignment, unit-to-unit consistency.

07

Compare the four units

Evaluate as a system too. A unit that looks normal can still be inconsistent with the other three.

Geometry

Control distance, elevation reference, azimuth, sensor alignment, unit reference and measurement position. A geometry error can mimic an aiming or intensity error on a healthy fitting.

Intensity

Compare against the applicable PAPI photometric requirement. Never apply a generic threshold without identifying the governing standard, equipment specification and operating condition. Low output can come from dirty lenses, optical deterioration, lamp or LED degradation, damaged reflector, electronic failure, wrong current, internal failure or a measurement geometry error: separate measurement error from equipment failure.

White/red transition

Shows whether the transition sits at the intended angle. Abnormal transition can come from incorrect aiming, optical damage, internal assembly movement, a filter or optical element problem, or mechanical displacement.

Reporting

Record Unit 1 to Unit 4 individually and give a system-level interpretation.

PAPI WING BAR · SIDE VIEW OF THE FOUR TRANSITION ANGLES 2°30′2°50′3°10′3°30′ 3°00′ ABOVE SLOPE · WHITE BELOW SLOPE · RED RUNWAY 21345 1Electrical checks2Elevation angle: inclinometer3Azimuth aiming along runway4Colour + sharp transition5Flight inspection SCHEMATIC · ANGLES EXAGGERATED, NOT TO SCALE · HIGHEST SETTING IS THE UNIT NEAREST THE RUNWAY
Figure 5. How a PAPI is tested: five checks for soundness, angle, aim and the colour change point.AGL Visual Encyclopedia: How is a PAPI tested?
Colour and Alignment

Colour, Chromaticity, Beam Alignment and Coverage

Colour versus chromaticity

Colour is the perceived or defined colour characteristic. Chromaticity specifies colour quantitatively in a defined colour space. Objective measurement matters most for formal acceptance. Changes can come from damaged filters, ageing optics, wrong replacement components, contamination, LED degradation or internal optical damage, so investigate rather than treating it as cosmetic.

Alignment and coverage

Alignment decides whether the useful output goes into the right angular region. A misaimed fitting can give reduced effective intensity, poor coverage, inconsistent guidance, glare in the wrong direction and non-uniform appearance. Coverage asks whether the light reaches the required region: peak intensity does not equal complete photometric compliance.

Elevated fittings

Alignment can shift through support movement, loose fasteners, impact, foundation movement or maintenance work. A light can pass an electrical test and fail alignment.

Inset fittings

Incorrect installation, pavement movement, displaced fixtures, damaged mounting or poor seating can leave the optics working but misoriented.

Acceptance

Photometric Acceptance

Acceptance must rest on the correct governing criteria: ICAO requirements, DGCA requirements, AAI specifications, approved project specifications, manufacturer requirements, and FAA criteria only where the project explicitly invokes them. Do not present FAA criteria as ICAO or DGCA requirements.

Pass

The relevant measured parameters comply with the applicable criteria.

Fail

Intensity, colour or chromaticity, coverage, aiming, configuration, distribution or another specified parameter is outside criteria.

Investigation required

Abnormal results needing measurement verification or engineering assessment before final classification.

No single intensity value applies to every AGL fitting: it varies with light type, colour, direction, beam, runway or taxiway function, operating condition, brightness setting and standard. State that measured values are compared with the applicable criteria for the specific system and project. For LED fittings, report input condition, brightness stage, measured intensity, colour, alignment and result to create a baseline.
Interactive

Rectification: Pick a Failed Result

A failed result should trigger a structured investigation. Pick a case to see the sequence.

Sequence

    Worth knowing

      Investigation order

      • Confirm the measurement: sensor, calibration, alignment, distance, geometry, operating condition
      • Visual: lens, glass, optics, contamination, housing, orientation, moisture
      • Electrical: transformer, connector, secondary lead, primary circuit, current, insulation
      • Mechanical: alignment, mounting, foundation, support, pavement seating

      Corrective action may be

      • Clean, realign, tighten, repair
      • Replace lens, optical component, driver or LED module
      • Replace transformer
      • Replace the complete fixture
      Retesting

      Retesting

      A corrected fitting is not just marked "repaired": it is measured again where the procedure requires performance verification.

      Failure
      Rectification
      Retest
      Closure
      01

      Identify the original failed measurement

      02

      Identify the corrective action

      03

      Repeat the relevant measurement

      04

      Compare the new result

      05

      Update the status

      06

      Close the defect if compliant

      After cleaning

      Confirms contamination was the cause.

      After aiming

      Retest aiming, coverage and intensity as applicable.

      After replacement

      Verify a new light unit, LED module, driver, lens or optical component under the appropriate condition. This sets a new baseline.

      Reporting

      The Photometric Report

      The report should let engineering staff answer: what was tested, when, with what equipment, under what conditions, what was measured, did it pass, where is the defect, was it corrected and was it retested.

      SectionContents
      1. Cover pageAirport, project or work order, location, date, service provider
      2. ScopeExactly what was tested, for example runway edge, threshold and PAPI
      3. Standards and criteriaDocuments used for evaluation. Avoid "ICAO compliant" without the documented basis
      4. EquipmentMake, model, serial, sensor, calibration, software, vehicle or frame ID
      5. Test conditionsCircuit, brightness stage, environment where relevant, geometry, method
      6. Asset registerLocation, fitting ID, type, circuit, station or position
      7. Measurement resultsPer fitting: intensity, colour, alignment, coverage, chromaticity, status
      8. Photometric diagramBeam shape, peak intensity, asymmetry, abnormal distribution where the equipment supports it
      9. Defect registerDefect, asset, problem, action, retest

      Example results table (format only)

      AssetTypeIntensityColourAlignmentCoverageChromaticityStatus
      RWY-EL-001EdgeMeasuredPassPassPassPassPASS
      RWY-EL-002EdgeLowPassPassFailPassFAIL
      PAPI-03PAPIMeasuredPassFailInvestigatePassFAIL

      Example defect register (format only)

      Defect IDAssetProblemActionRetest
      D-001RWY-EL-027Low intensityCleanedPass
      D-002RWY-EL-041Incorrect aimingRealignedPass
      D-003PAPI-Unit-3Optical issueRepairedPass
      D-004TWY-CL-018Low outputReplacedPending
      All tables and figures here are illustrative layouts, not real airport results. Present actual results only against the applicable project acceptance criteria.

      Typical deliverables

      • Field photometric survey and fixture-wise results
      • Photometric diagrams where applicable, colour and chromaticity results, aiming and alignment results
      • Defect register and corrective-action register
      • Retest results and final summary report
      • Digital data, and hard copy where contractually required
      PHOTOMETRIC REPORT · SIX THINGS TO READ, IN ORDER 1 IDENTIFY What was tested 2 CONDITIONS Current, distance 3 DATA Table & isocandela 4 COMPARE Against requirement 5 COLOUR Chromaticity 6 CONCLUDE Result & limits EXAMPLE REPORT SHEET · READ AGAINST THE REQUIREMENT, NOT ON ITS OWN 1 FIXTURE · SOURCE · COLOUR · LABORATORY · DATE 2 RATED CURRENT · TEST DISTANCE · STANDARD USED 3 ISOCANDELA DIAGRAM · DASHED BOX = REQUIRED AREA 5 CHROMATICITY x, y inside the colour limits 4 POINT-BY-POINT COMPARISON POINT REQUIRED MIN MEASURED RESULT A (0, 0) 1500 cd 1850 cd PASS B (+2, 0) 1000 cd 1120 cd PASS C (-2, 0) 1000 cd 960 cd FAIL D (0, +1) 800 cd 880 cd PASS ONE POINT BELOW ITS LIMIT IS A FAILURE · EXAMPLE VALUES ONLY 6 RESULT APPLIES TO THE TESTED SAMPLE UNDER STATED CONDITIONS SCHEMATIC · EXAMPLE VALUES ONLY · REQUIRED POINTS AND LIMITS COME FROM THE APPLICABLE STANDARD
      Figure 6. Reading a photometric report: what was tested, what was measured and whether it meets the requirement.AGL Visual Encyclopedia: How do you read a photometric report?
      Checklist

      AGL Photometry Checklist

      Click an item to mark it complete.

      Before and during set-up

      Approved drawings reviewed
      Lighting inventory available
      Test criteria identified
      Equipment calibrated or verified
      Sensor, frame and vehicle inspected
      Safety and airside coordination completed
      Correct runway or taxiway and circuit energized
      Correct brightness condition selected
      Measurement geometry established and sensor aligned
      Asset identification confirmed
      0 / 10 complete

      During measurement and evaluation

      Data recorded correctly
      Fitting position verified
      Abnormal results repeated
      Environmental conditions recorded
      Intensity checked
      Colour and chromaticity checked where applicable
      Coverage and beam spread checked
      Alignment and configuration checked
      0 / 8 complete

      After failure and final report

      Measurement verified
      Physical inspection completed
      Electrical investigation completed where needed
      Corrective action recorded
      Retest completed
      Equipment details and test conditions included
      Raw and processed results retained as required
      Failed fittings, corrective actions and retest status included
      Final summary completed
      0 / 9 complete

      Field workflow

      Document review
      Site inspection
      Equipment verification
      Measurement set-up
      Circuit preparation
      Photometric measurement
      Data validation
      Acceptance evaluation
      Defect identification
      Rectification
      Retesting
      Final report
      Project Types

      Commissioning, Periodic Inspection and Maintenance

      New commissioning

      Material inspection, installation inspection, electrical testing, functional testing, photometric testing, defect correction, retesting, final acceptance. This stops optical acceptance before basic installation and electrical problems are resolved.

      Periodic inspection

      Review the previous report and current asset inventory, visual inspection, photometric survey, trend comparison, defect classification, maintenance, retest.

      Trend analysis

      A history reveals progressive deterioration before failure. Illustrative only: baseline 100%, then 95%, 91%, 86% over three years, then maintenance required. The value is the ability to spot decline, not the particular numbers.

      Condition-based maintenance

      Instead of replacing by age, measure, evaluate, prioritize: clean, align, repair, replace a component or replace the fitting. Link results to maintenance records and a digital asset database (asset ID, location, type, manufacturer, circuit, photometric, failure and maintenance history).

      Integration

      Photometry and the Rest of the AGL System

      Electrical testing

      Run electrical, functional, then photometric tests. A dim fitting leads to transformer, secondary cable, connector, fitting, optics.

      CCR and operating condition

      Record the CCR and circuit condition. A failure at one intensity level may not read the same at another.

      Redundancy

      Test normal configuration and, where required, a defined failure configuration to show the remaining system keeps required guidance.

      Emergency power

      Normal power, power failure, UPS or DG transition, AGL stabilization, photometric verification.

      Lightning events

      After a significant event: visual inspection, electrical testing, surge investigation, functional test, photometry.

      A-SMGCS / Follow the Greens

      Photometry verifies the physical lighting; control and operational tests are separate.

      Asset management

      Link results to an asset database: asset ID, location, fitting type, manufacturer, installation date, circuit, and photometric, failure and maintenance history. This is the foundation for predictive maintenance.

      Avoid These

      Common Errors, Safety and Quality

      1

      Incorrect measurement geometry

      The sensor is not positioned correctly.

      2

      Wrong circuit condition

      Fitting measured at an unintended operating condition.

      3

      Poor asset identification

      A reading assigned to the wrong light.

      4

      Unverified calibration

      Traceability is unclear.

      5

      Dirty sensor or lens

      The instrument itself affects the result.

      6

      Not repeating abnormal results

      A measurement error gets classified as an equipment failure.

      7

      No visual inspection

      A simple contamination or alignment problem is missed.

      8

      No retest

      "Repaired" is reported without confirming optical performance.

      9

      Generic acceptance criteria

      A universal value applied to different fitting types.

      Airside safety

      Coordinate runway or taxiway access, ATC, airport operations, vehicle permits, radio, restricted-area access, work windows, circuit switching and escorts per the airport's approved airside-work requirements. It is not a roadside lighting inspection.

      Quality assurance

      Calibrated equipment, trained people, standardized set-up, documented method, repeatability checks, asset traceability, controlled data processing, report review, and second-level review of abnormal data for important surveys.

      Team competence

      Operators should understand AGL architecture, visual aids, CCR operation, transformers, optical alignment, PAPI, airport safety, measurement principles and data interpretation, so a low reading is investigated, not just reported.

      Standards

      Standards and Indian Context

      For Indian airport work, establish the procedure from the applicable combination of ICAO, DGCA, AAI, airport-specific requirements, the project technical specification and manufacturer requirements. Take exact acceptance values from the project documentation, not from an unrelated airport.

      ICAO
      DGCA
      AAI
      Airport-specific requirements
      Project technical specification
      Manufacturer requirements

      ICAO reference

      Aerodrome Design Manual Part 4, Visual Aids (Doc 9157 Part 4), covers the characteristics of visual aids including approach, runway and taxiway lighting. The ICAO Store lists the 5th Edition, 2021, with Amendment 2 dated 15 September 2025.

      AAI evidence

      AAI procurement documents show detailed in-field measurement scopes (intensity, beam spread, orientation, colour, candela, coverage, chromaticity, alignment) and dedicated photometry testing at Indian airports, with test reports submitted and, depending on the package, corrective actions.

      AAI contract requirements are contract-specific. Do not treat their test intervals or scopes as a universal requirement. Confirm current editions of every reference before relying on it.
      HOW AN INDIAN LIGHTING REQUIREMENT IS ASSEMBLEDFROM THE ICAO BASELINE TO YOUR AIRPORTICAO ANNEX 14 VOLUME ISARPsGlobal SARPs that India follows as a Contracting StateBHARATIYA VAYUYAN ADHINIYAM, 2024LAWReplaced the Aircraft Act, 1934. DGCA is the safety regulatorDGCA CAR SECTION 4 SERIES B PART ITHE CARAerodrome Design & Operations. Paragraph numbers follow Annex 14AIP INDIAAAIGEN 1.7 lists differences from ICAO. Supplements carry airport-specific proceduresYOUR PROJECTPROJECTTender specification, aerodrome manual and the airport operator's requirementsCITED IN DGCA AND AAI DOCUMENTS5.3.18.3Taxiway edge lightsCited in a DGCA investigation report, 2024PARA 8 · TABLE 8-1Secondary power switch-over timesCited in AAI AIP Supplement 204/20256.2.2Marking of mobile objectsCited in the same DGCA reportNUMBERING FOLLOWS ANNEX 14Each paragraph above sits where Annex 14puts the same subject. Where India's textdeparts from ICAO, see the next entry.
      Figure 7. DGCA CAR requirements for aerodrome lighting in India, which follow ICAO Annex 14.AGL Visual Encyclopedia: What does the DGCA CAR require for aerodrome lighting in India?
      Final Engineering Perspective

      A photometric test is a controlled engineering process, and a low reading can come from contamination, aiming, electrical problems, optical deterioration or measurement error. Find the cause before you act.

      Prepare. Measure. Validate. Evaluate. Correct. Retest. Document.

      Test Yourself

      Quick Knowledge Check

      Q1. What does a photometric test establish that a functional test does not?

      A. That the light switches on
      B. That the light gives the required optical output
      C. That the cable is buried
      D. That the CCR is cold

      Q2. What do the "4Cs" in AAI specifications stand for?

      A. Cable, Circuit, Current, Connector
      B. Configuration, Colour, Candela, Coverage
      C. Calibration, Checking, Cleaning, Closure
      D. Centreline, Circuit, CCR, Control

      Q3. An unexpectedly low reading appears. What first?

      A. Replace the fitting
      B. Verify the set-up and repeat the reading
      C. Ignore it
      D. Raise the brightness step

      Q4. Why can a photometer not fully test a stop bar?

      A. Stop bars have no optics
      B. It cannot verify the interlocking and control logic
      C. They are always on
      D. They are too bright

      Q5. Why retest after cleaning or realigning?

      A. Not needed
      B. To prove by measurement that performance was restored
      C. For paperwork only
      D. To change the criteria
      Explore More

      Explore More AGL Engineering

      FUNDAMENTALS

      AGL Photometry

      Photometry concepts and reporting.

      Open AGL Photometry →
      FIELD GUIDE

      AGL Photometric Testing Guide

      Equipment, procedure and troubleshooting.

      Open AGL Photometric Testing Guide →
      FIELD GUIDE

      Runway Lighting Photometry

      Runway fixture testing.

      Open Runway Lighting Photometry →
      FIELD GUIDE

      Taxiway Lighting Photometry

      Taxiway fixture testing.

      Open Taxiway Lighting Photometry →
      VISUAL AID

      PAPI Alignment & Maintenance

      PAPI alignment and field practice.

      Open PAPI Alignment & Maintenance →
      STANDARDS

      ICAO PAPI Requirements

      ICAO PAPI requirements.

      Open ICAO PAPI Requirements →
      STANDARDS

      ICAO Aerodrome Lighting Requirements

      The ICAO AGL framework.

      Open ICAO Aerodrome Lighting Requirements →
      SYSTEM

      How Airfield Lighting Works

      The chain from power to optical output.

      Open How Airfield Lighting Works →
      HUB

      AGL Components

      Electrical, lighting, mechanical and control components.

      Open AGL Components →
      PROCESS

      Testing & Commissioning

      Electrical, optical and handover testing.

      Open Testing & Commissioning →
      MAINTENANCE

      AGL Maintenance

      Preventive and corrective maintenance.

      Open AGL Maintenance →
      ELECTRICAL

      CCR Working Principle

      Series circuits and current steps.

      Open CCR Working Principle →

      Measure It. Fix It. Prove It.

      From survey planning to defect registers and retests, explore the complete AGL knowledge base.

      AGL Engineering Hub

      Explore the AGL Engineering Knowledge Hub

      Fundamentals

      Standards & Compliance

      Runway, Taxiway & Approach Lighting

      Surface Movement & Safety

      PAPI

      Electrical Engineering & Power

      Photometry & Testing

      Maintenance, Inspection & Safety

      Resources, Documentation & Careers

      FAQ

      AGL Photometric Testing Procedure FAQ

      Q1What is the AGL photometric testing procedure?

      A typical procedure runs: document review, visual inspection, equipment verification, measurement set-up, circuit preparation, photometric measurement, data analysis, defect identification, rectification, retesting and a final report.

      Q2What equipment is required for AGL photometry?

      Typically an airport photometer, calibrated sensor, measurement frame, positioning equipment and data-acquisition software. Large airports may also use vehicle-mounted mobile photometric systems. AAI specifications show both vehicle-mounted and portable approaches.

      Q3What parameters are measured during AGL photometry?

      Depending on the fitting: intensity, beam spread, orientation, colour, candela, coverage, chromaticity, configuration and other applicable parameters.

      Q4How is runway photometry performed?

      Review the lighting layout, align the measurement system to the runway reference, energize the circuit at the required operating condition, then measure and evaluate each required fitting or segment.

      Q5How is taxiway photometry different?

      The principle is the same, but the programme follows the taxiway configuration and may include edge lights, centreline lights, stop bars and runway guard lights.

      Q6How is PAPI photometry performed?

      It combines physical inspection, horizontal and vertical aiming verification, intensity measurement, colour assessment and evaluation of the white/red transition using suitable equipment.

      Q7Is PAPI intensity testing the same as PAPI aiming?

      No. Intensity measures optical output, while aiming establishes the angular direction of the beam. Both affect the final visual guidance.

      Q8Can a PAPI be on but still fail photometry?

      Yes. Electrical operation does not prove correct intensity, colour, beam distribution or aiming.

      Q9What is 4C AGL testing?

      In AAI technical specifications, 4C means Configuration, Colour, Candela and Coverage. Those specifications may also require chromaticity and other measurements.

      Q10What happens when an AGL light fails photometry?

      First confirm the measurement. Then inspect the fitting, electrical circuit, transformer, connector, optical assembly and alignment. Clean, realign, repair or replace as appropriate, then retest.

      Q11Should every failed light be replaced?

      No. A failure can come from contamination, aiming or other correctable conditions. Identify the cause before replacing.

      Q12Why is retesting important?

      It proves that the corrective action restored the required optical performance and closes the defect with measured evidence.

      Q13Can photometry be done using a vehicle?

      Yes. Vehicle-mounted systems suit large runway and taxiway surveys, and AAI procurement documents provide for them.

      Q14Can PAPI be tested using a handheld instrument?

      Yes, if the instrument and method suit PAPI. AAI's portable photometric specification covers AGL and PAPI measurements.

      Q15Is colour measured during AGL photometry?

      Where required. Colour and chromaticity are recognized field-testing parameters in AAI specifications.

      Q16What is the difference between photometry and electrical testing?

      Electrical testing evaluates the condition and behaviour of the electrical system. Photometry evaluates the optical performance of the installed light.

      Q17What is the acceptance limit for runway lights?

      There is no single universal value. It depends on the specific light, operating condition, runway function and governing specification.

      Q18How often should AGL photometry be performed?

      It depends on the approved maintenance programme, airport requirements, operational category, authority requirements and contract specification. AAI procurement examples include annual and multi-year testing, but those are not a universal frequency.

      Field Insight

      Engineering & Expert Notes

      Plan the Test Before Going Out
      Preparation

      Agree locations, instruments, step settings and access arrangements in advance. A prepared plan reduces runway occupancy and rework.

      Measure at the Intensity Step Stated in the Requirement
      Settings

      Confirm CCR step and current before each reading, because output changes with setting. Record the step used.

      Position the Sensor Consistently
      Positioning

      Small changes in sensor position or angle can alter results. Use marked points or fixtures to repeat the geometry.

      Handle a Failed Result Methodically
      Failures

      Check the setup, clean the optic and verify alignment before declaring a failure. Then rectify and retest, keeping both records.

      Do Not Skip the Colour Check
      Colour

      Colour compliance is part of acceptance. Measure chromaticity where required rather than relying on appearance.

      Archive Raw Data With the Report
      Records

      Keep readings and photos alongside the summary so findings can be reviewed or challenged later.

      Precision AGL Academy

      Understand AGL. Build Your Engineering Skills.

      You now understand the field procedure for AGL photometric testing, from preparation and measurement to rectification, retesting and reporting.

      Take the next step with Precision AGL Academy.

      Learn AGL Step by Step

      Build your knowledge through structured technical learning covering:

      AGL Fundamentals Components Electrical Systems Design Photometry Testing Troubleshooting Maintenance

      Move from understanding how AGL works to developing the practical knowledge needed to analyse, operate and maintain complete AGL systems.

      Understand the system. Build the knowledge. Apply the engineering.